PURPOSE: To investigate the feasibility of using an electromagnetic (EM) tracker to estimate rigid body head motion parameters, and using these measurements to retrospectively reduce motion artifacts. THEORY AND METHODS: A clinically used MPRAGE sequence was modified to measure motion using the EM tracking system once per repetition time. A retrospective k-space based motion correction algorithm that corrects for phase ramps (translation in image domain) and rotation of 3D k-space (rotation in image domain) was developed, using the parameters recorded using an EM tracker. The accuracy of the EM tracker for the purpose of motion measurement and correction was tested in phantoms, volunteers, and pediatric patients. RESULTS: Position localization was accurate to the order of 200 microns compared with registration localization in a phantom study. The quality of reconstructed images was assessed by computing the root mean square error, the structural similarity metric and average edge strength. Image quality improved consistently when motion correction was applied in both volunteer scans with deliberate head motion and in pediatric patient scans. In patients, the average edge strength improved significantly with retrospective motion correction, compared with images with no correction applied. CONCLUSIONS: EM tracking was effective in measuring head motion in the MRI scanner with high accuracy, and enabled retrospective reconstruction to improve image quality by reducing motion artifacts.
PURPOSE: To investigate the feasibility of using an electromagnetic (EM) tracker to estimate rigid body head motion parameters, and using these measurements to retrospectively reduce motion artifacts. THEORY AND METHODS: A clinically used MPRAGE sequence was modified to measure motion using the EM tracking system once per repetition time. A retrospective k-space based motion correction algorithm that corrects for phase ramps (translation in image domain) and rotation of 3D k-space (rotation in image domain) was developed, using the parameters recorded using an EM tracker. The accuracy of the EM tracker for the purpose of motion measurement and correction was tested in phantoms, volunteers, and pediatric patients. RESULTS: Position localization was accurate to the order of 200 microns compared with registration localization in a phantom study. The quality of reconstructed images was assessed by computing the root mean square error, the structural similarity metric and average edge strength. Image quality improved consistently when motion correction was applied in both volunteer scans with deliberate head motion and in pediatric patient scans. In patients, the average edge strength improved significantly with retrospective motion correction, compared with images with no correction applied. CONCLUSIONS: EM tracking was effective in measuring head motion in the MRI scanner with high accuracy, and enabled retrospective reconstruction to improve image quality by reducing motion artifacts.
Authors: Murat Aksoy; Christoph Forman; Matus Straka; Tolga Çukur; Joachim Hornegger; Roland Bammer Journal: Magn Reson Med Date: 2011-08-08 Impact factor: 4.668
Authors: Murat Aksoy; Christoph Forman; Matus Straka; Stefan Skare; Samantha Holdsworth; Joachim Hornegger; Roland Bammer Journal: Magn Reson Med Date: 2011-03-22 Impact factor: 4.668
Authors: Melvyn B Ooi; Sascha Krueger; William J Thomas; Srirama V Swaminathan; Truman R Brown Journal: Magn Reson Med Date: 2009-10 Impact factor: 4.668
Authors: Onur Afacan; W Scott Hoge; Tess E Wallace; Ali Gholipour; Sila Kurugol; Simon K Warfield Journal: J Neuroimaging Date: 2020-05-06 Impact factor: 2.486
Authors: Tess E Wallace; Jonathan R Polimeni; Jason P Stockmann; W Scott Hoge; Tobias Kober; Simon K Warfield; Onur Afacan Journal: Magn Reson Med Date: 2020-09-24 Impact factor: 4.668