Literature DB >> 31389877

CORR Insights®: Tilt-adjusted Cup Anteversion in Patients with Severe Backward Pelvic Tilt is Associated with the Risk of Iliopsoas Impingement: A Three-dimensional Implantation Simulation.

Thomas Ilchmann1.   

Abstract

Entities:  

Mesh:

Year:  2019        PMID: 31389877      PMCID: PMC6999929          DOI: 10.1097/CORR.0000000000000875

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


× No keyword cloud information.
  11 in total

Review 1.  The influence of sagittal spinal deformity on anteversion of the acetabular component in total hip arthroplasty.

Authors:  D Phan; S S Bederman; Ran Schwarzkopf
Journal:  Bone Joint J       Date:  2015-08       Impact factor: 5.082

2.  An examination chair to measure internal rotation of the hip in routine settings: a validation study.

Authors:  S Reichenbach; P Jüni; E Nüesch; F Frey; R Ganz; M Leunig
Journal:  Osteoarthritis Cartilage       Date:  2009-10-08       Impact factor: 6.576

3.  What are the radiographic reference values for acetabular under- and overcoverage?

Authors:  Moritz Tannast; Markus S Hanke; Guoyan Zheng; Simon D Steppacher; Klaus A Siebenrock
Journal:  Clin Orthop Relat Res       Date:  2015-04       Impact factor: 4.176

4.  Tilt-adjusted Cup Anteversion in Patients with Severe Backward Pelvic Tilt is Associated with the Risk of Iliopsoas Impingement: A Three-dimensional Implantation Simulation.

Authors:  Takuro Ueno; Tamon Kabata; Yoshitomo Kajino; Takaaki Ohmori; Junya Yoshitani; Ken Ueoka; Hiroyuki Tsuchiya
Journal:  Clin Orthop Relat Res       Date:  2019-10       Impact factor: 4.176

5.  Calculation of impingement-free combined cup and stem alignments based on the patient-specific pelvic tilt.

Authors:  Juliana Hsu; Matias de la Fuente; Klaus Radermacher
Journal:  J Biomech       Date:  2018-10-28       Impact factor: 2.712

6.  Analysis of the Pelvic Functional Orientation in the Sagittal Plane: A Radiographic Study With EOS 2D/3D Technology.

Authors:  Mattia Loppini; Umile Giuseppe Longo; Pasquala Ragucci; Nicoletta Trenti; Luca Balzarini; Guido Grappiolo
Journal:  J Arthroplasty       Date:  2016-09-28       Impact factor: 4.757

Review 7.  Cup positioning in total hip arthroplasty.

Authors:  T Scheerlinck
Journal:  Acta Orthop Belg       Date:  2014-09       Impact factor: 0.500

8.  Differences in range of motion with the same combined anteversion after total hip arthroplasty.

Authors:  Takaaki Ohmori; Tamon Kabata; Yoshitomo Kajino; Tadashi Taga; Kazuhiro Hasegawa; Daisuke Inoue; Takashi Yamamoto; Tomoharu Takagi; Junya Yoshitani; Takuro Ueno; Hiroyuki Tsuchiya
Journal:  Int Orthop       Date:  2017-10-09       Impact factor: 3.075

9.  Three-Dimensional Host Bone Coverage Required in Total Hip Arthroplasty for Developmental Dysplasia of the Hip and Its Relationship With 2-Dimensional Coverage.

Authors:  Takuro Ueno; Tamon Kabata; Yoshitomo Kajino; Takaaki Ohmori; Junya Yoshitani; Hiroyuki Tsuchiya
Journal:  J Arthroplasty       Date:  2018-09-27       Impact factor: 4.757

10.  Excellent long-term results of the Müller acetabular reinforcement ring in primary total hip arthroplasty: A prospective study on radiology and survival of 321 hips with a mean follow-up of 11 years.

Authors:  Aurimas Sirka; Martin Clauss; Sarunas Tarasevicius; Hans Wingstrand; Justinas Stucinskas; Otto Robertsson; Peter Emil Ochsner; Thomas Ilchmann
Journal:  Acta Orthop       Date:  2015-10-16       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.