Literature DB >> 3137317

An improved tungsten-178/tantalum-178 generator system for high volume clinical applications.

J L Lacy1, M E Ball, M S Verani, H B Wiles, J W Babich, A D LeBlanc, M Stabin, L Bolomey, R Roberts.   

Abstract

Clinical utilization of the multiwire gamma camera (MWGC) requires low-energy radionuclides. The short-lived (9.3 min) tantalum-178 (178Ta) is ideally suited for the MWGC and can be produced from long-lived (21.7 day) tungsten-178 (178W) by a previously reported 178W/178Ta generator. This generator, however, is limited by sharp increase in breakthrough after elution of only 30-60 column-volumes. To optimize the 178W/178Ta generator for clinical use, varying eluant acid concentrations were evaluated. A reduced (from 0.1 to 0.03N) HCI concentration in the eluant, coupled with low operating temperatures (3 to 5 degrees C) allowed high (40 to 60%) 178Ta yield. Minimal 178W breakthrough (less than .01%) resulted, even after elution of more than 200 column-volumes. Each of six tested generators provided sterile, high activity (up to 100 mCi) 178Ta elutions for more than 30 days. Radiation dosimetry was estimated utilizing both human and animal biodistribution data. The whole body (critical organ) dose in adults and neonates were 1/20 (1/21) and 1/19 (1/50) respectively relative to that of technetium-99m (99mTc) as sodium pertechnetate. The optimized 178W/178Ta generator provides a commercially practical, safe source of low-energy radioisotope for the MWGC with substantial dosimetry advantages over 99mTc.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3137317

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

1.  Assessment of left ventricular function during upright treadmill exercise with tantalum 178 and multiwire gamma camera.

Authors:  Jaekyeong Heo; Thein Htay; Deval Mehta; Liang Sun; Jeffrey Lacy; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

Review 2.  Wire chambers revisited.

Authors:  R J Ott
Journal:  Eur J Nucl Med       Date:  1993-04

Review 3.  The continuing important role of radionuclide generator systems for nuclear medicine.

Authors:  F F Knapp; S Mirzadeh
Journal:  Eur J Nucl Med       Date:  1994-10

4.  Development and validation of a novel technique for murine first-pass radionuclide angiography with a fast multiwire camera and tantalum 178.

Authors:  J L Lacy; T Nanavaty; D Dai; N Nayak; N Haynes; C Martin
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.