Literature DB >> 24748583

Impact of strut-vessel distance and underlying plaque type on the resolution of acute strut malapposition: serial optimal coherence tomography analysis after everolimus-eluting stent implantation.

Takumi Inoue1, Toshiro Shinke, Hiromasa Otake, Masayuki Nakagawa, Hirotoshi Hariki, Tsuyoshi Osue, Masamichi Iwasaki, Yu Taniguchi, Ryo Nishio, Noritoshi Hiranuma, Akihide Konishi, Hiroto Kinutani, Masaru Kuroda, Ken-ichi Hirata.   

Abstract

The consequences of acute strut malapposition in everolimus-eluting stents (EES) are unknown. This study investigated the impact of strut-vessel (S-V) distance and plaque type underneath acute strut malapposition on the mid-term vessel response in EES. Twenty-nine patients (35 EES) underwent optical coherence tomography (OCT) immediately after percutaneous coronary intervention and at 8-month follow-up. S-V distance and plaque type (lipid, calcified, or fibrous) underneath acute strut malapposition were evaluated. Follow-up OCT classified acute strut malapposition as persistent or resolved. The S-V cutoff value for predicting resolved strut malapposition and the incidence of intra-stent thrombi were determined. Among 569 cases of acute strut malapposition, involving 29,168 struts, 139 (24.4 %) were persistent. Mean S-V distance was significantly longer in persistent than in resolved strut malapposition (600 ± 294 vs. 231 ± 95 μm; P < 0.0001). S-V distance ≤380 μm was the best cutoff value for predicting resolved strut malapposition (sensitivity 93.5 %, specificity 69.8 %, area under curve 0.878). Acute strut malapposition with S-V distance ≤380 μm remained persistent more frequently over lipid/calcified than over fibrous plaques (lipid: 13.4 %, calcified: 18.2 %, fibrous: 4.2 %; lipid vs. fibrous, P = 0.001; calcified vs. fibrous, P = 0.02). Intra-stent thrombi were more frequent in stents with ≥1 persistent strut malapposition than in those without [4/11 stents (36.3 %) vs. 0/24 (0 %); P = 0.006]. Lipid and calcified plaque, together with S-V distance, affect the resolution of acute strut malapposition in EES. Persistent strut malapposition is associated with the presence of thrombi at follow-up, which could be the substrate for late stent thrombosis.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24748583     DOI: 10.1007/s10554-014-0422-z

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  20 in total

1.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound.

Authors:  Ik-Kyung Jang; Brett E Bouma; Dong-Heon Kang; Seung-Jung Park; Seong-Wook Park; Ki-Bae Seung; Kyu-Bo Choi; Milen Shishkov; Kelly Schlendorf; Eugene Pomerantsev; Stuart L Houser; H Thomas Aretz; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2002-02-20       Impact factor: 24.094

2.  Outcome after acute incomplete sirolimus-eluting stent apposition as assessed by serial intravascular ultrasound.

Authors:  Masashi Kimura; Gary S Mintz; Stéphane Carlier; Hideo Takebayashi; Kenichi Fujii; Koichi Sano; Takenori Yasuda; Ricardo A Costa; Jose R Costa; Jie Quen; Kaoru Tanaka; Joanna Lui; Giora Weisz; Issam Moussa; George Dangas; Roxana Mehran; Alexandra J Lansky; Edward M Kreps; Michael Collins; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  Am J Cardiol       Date:  2006-06-19       Impact factor: 2.778

3.  The ability of optical coherence tomography to monitor percutaneous coronary intervention: detailed comparison with intravascular ultrasound.

Authors:  Hiroyuki Kawamori; Junya Shite; Toshiro Shinke; Hiromasa Otake; Takahiro Sawada; Hiroki Kato; Naoki Miyoshi; Naoki Yoshino; Amane Kozuki; Hirotoshi Hariki; Takumi Inoue; Ken-ichi Hirata
Journal:  J Invasive Cardiol       Date:  2010-11       Impact factor: 2.022

4.  Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition.

Authors:  Jun Tanigawa; Peter Barlis; Carlo Di Mario
Journal:  EuroIntervention       Date:  2007-05       Impact factor: 6.534

5.  Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach.

Authors:  N Gonzalo; P W Serruys; T Okamura; Z J Shen; Y Onuma; H M Garcia-Garcia; G Sarno; C Schultz; R J van Geuns; J Ligthart; E Regar
Journal:  Heart       Date:  2009-08-10       Impact factor: 5.994

6.  Optical coherence evaluation of everolimus-eluting stents 8 months after implantation.

Authors:  Takumi Inoue; Junya Shite; Junghan Yoon; Toshiro Shinke; Hiromasa Otake; Takahiro Sawada; Hiroyuki Kawamori; Hiroki Katoh; Naoki Miyoshi; Naoki Yoshino; Amane Kozuki; Hirotoshi Hariki; Ken-Ichi Hirata
Journal:  Heart       Date:  2010-11-04       Impact factor: 5.994

7.  In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography.

Authors:  Ik-Kyung Jang; Guillermo J Tearney; Briain MacNeill; Masamichi Takano; Fabian Moselewski; Nicusor Iftima; Milen Shishkov; Stuart Houser; H Thomas Aretz; Elkan F Halpern; Brett E Bouma
Journal:  Circulation       Date:  2005-03-21       Impact factor: 29.690

8.  Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myocardial infarction: an intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial.

Authors:  Ning Guo; Akiko Maehara; Gary S Mintz; Yong He; Kai Xu; Xiaofan Wu; Alexandra J Lansky; Bernhard Witzenbichler; Giulio Guagliumi; Bruce Brodie; Mirle A Kellett; Ovidiu Dressler; Helen Parise; Roxana Mehran; Gregg W Stone
Journal:  Circulation       Date:  2010-08-30       Impact factor: 29.690

9.  Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study.

Authors:  Takashi Kubo; Toshio Imanishi; Hironori Kitabata; Akio Kuroi; Satoshi Ueno; Takashi Yamano; Takashi Tanimoto; Yoshiki Matsuo; Takashi Masho; Shigeho Takarada; Atsushi Tanaka; Nobuo Nakamura; Masato Mizukoshi; Yoshiaki Tomobuchi; Takashi Akasaka
Journal:  JACC Cardiovasc Imaging       Date:  2008-07

10.  Fusion of 3D QCA and IVUS/OCT.

Authors:  Shengxian Tu; Niels R Holm; Gerhard Koning; Zheng Huang; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-25       Impact factor: 2.357

View more
  7 in total

1.  Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.

Authors:  Daisuke Izumi; Masatoshi Miyahara; Naoki Fujimoto; Shusuke Fukuoka; Masataka Sakai; Kaoru Dohi; Masaaki Ito
Journal:  Heart Vessels       Date:  2015-09-03       Impact factor: 2.037

2.  Cut-off value of mal-apposition volume and depth for resolution at early phase of acute incomplete stent apposition after CoCr-EES implantation.

Authors:  Yohei Uchimura; Tomonori Itoh; Hideto Oda; Yuya Taguchi; Wataru Sasaki; Kyosuke Kaneko; Tsubasa Sakamoto; Iwao Goto; Masafumi Sakuma; Masaru Ishida; Tatsuo Kikuchi; Daisuke Terashita; Hiromasa Otake; Yoshihiro Morino; Toshiro Shinke
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-29       Impact factor: 2.357

Review 3.  A Practical Approach to Assessing Stent Results with IVUS or OCT.

Authors:  Daisuke Hachinohe; Satoru Mitomo; Luciano Candilio; Azeem Latib
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Jan-Mar

4.  Impact of lesion angle on optical coherence tomography findings and clinical outcomes after drug-eluting stent implantation in curved vessels.

Authors:  Shun Nakamura; Shigeki Kimura; Shun Nakagama; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Keiichi Hishikari; Hiroyuki Hikita; Atsushi Takahashi; Kenzo Hirao
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-29       Impact factor: 2.357

5.  Impact of lesion complexity on long-term vascular response to cobalt-chromium everolimus-eluting stent: five-year follow-up optical coherence tomography study.

Authors:  Shoichi Kuramitsu; Shinjo Sonoda; Tomohiro Shinozaki; Hiroyuki Jinnouch; Yoshitaka Muraoka; Takenori Domei; Makoto Hyodo; Shinichi Shirai; Kenji Ando; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2017-10-19       Impact factor: 2.037

6.  Predictors and Long-Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) Intravascular Ultrasound Substudy.

Authors:  Bin Wang; Gary S Mintz; Bernhard Witzenbichler; Cristiano F Souza; D Christopher Metzger; Michael J Rinaldi; Peter L Duffy; Giora Weisz; Thomas D Stuckey; Bruce R Brodie; Mitsuaki Matsumura; Myong-Hwa Yamamoto; Rupa Parvataneni; Ajay J Kirtane; Gregg W Stone; Akiko Maehara
Journal:  J Am Heart Assoc       Date:  2016-12-22       Impact factor: 5.501

7.  Insulin-like growth factor-1 levels predict myocardial injury and infarction after elective percutaneous coronary intervention: an optical coherence tomography study.

Authors:  Onur Tasar; Gonenc Kocabay; Yavuz Karabag; Arzu Kalayci Karabay; Can Yucel Karabay; Sedat Kalkan; Cevat Kirma
Journal:  Postepy Kardiol Interwencyjnej       Date:  2020-06-23       Impact factor: 1.426

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.