Literature DB >> 31354203

Outflow Facility in Tube Shunt Fenestration.

Jessica Olayanju1, Teresa Borras1, Bahjat Qaqish2, David Fleischman1.   

Abstract

AIM: Determination of the effect of varying fenestration technique, and simulated patch graft on outflow facility for Baerveldt tube.
MATERIALS AND METHODS: Silicone tubing similar to Baerveldt implant (AMO, Santa Ana, CA) with different fenestrations techniques was connected to a digital manometer in a closed system with a fluid-filled syringe on a stand to adjust pressure. The venting slits included: (A) 4 piercings with 7-0 TG140-8 needle; (B) a 2-mm slit with a 15° blade; (C) 4 piercings with a 15° blade; (D) 9-0 Nylon on CS140-6 needle with suture stenting the fenestration.
RESULTS: For pressures of 10, 20, 30, 40 mm Hg in groups A to D, the average outflow facility (mL/min/mm Hg) were group A: 0.11, 0.20, 0.28, 0.40; group B: 0.30, 0.69, 0.98, 0.93; group C: 0.73, 0.80, 0.81, 0.88; group D: 0.58, 0.65, 0.80, 0.87. For external compression with 10 gram weights at pressures of 10, 20, 30, 40 mm Hg, outflow were group A: 0.0, 0.18, 0.20, 0.53; group B: 0.75, 0.70, 0.97, 1.21. Group C: 0.18, 0.03, 0.57, 0.04. Group D: 0.73, 0.90, 1.13, 0.91.
CONCLUSION: Effectivity of venting slits in maintaining adequate IOP in the early postoperative period for non-valved glaucoma implant is variable, multifactorial and largely intraocular pressure (IOP) dependent. CLINICAL SIGNIFICANCE: This study explores methods of producing fenestration and the effects on outflow at different pressures in an attempt to determine which fenestration technique has more reproducible results that can be made applicable in clinical practice. This is also the first study to evaluate the effect of external pressures similar to scleral patch graft on the tube fenestrations. HOW TO CITE THIS ARTICLE: Olayanju J, Borras T, Qaqish B, Fleischman D. Outflow Facility in Tube Shunt Fenestration. J Curr Glaucoma Pract 2018;12(3):113-118.

Entities:  

Keywords:  Aqueous shunt; Baerveldt; Fenestration; Venting slit

Year:  2018        PMID: 31354203      PMCID: PMC6647827          DOI: 10.5005/jp-journals-10028-1255

Source DB:  PubMed          Journal:  J Curr Glaucoma Pract        ISSN: 0974-0333


  18 in total

1.  Postoperative pressure regulation in glaucoma shunt surgery: focal tube constriction is not the answer.

Authors:  Eelco Rietveld; Albert Jan van der Veen
Journal:  J Glaucoma       Date:  2004-06       Impact factor: 2.503

2.  Comparing glaucoma drainage implants.

Authors:  Steven J Gedde; Richard K Lee
Journal:  Am J Ophthalmol       Date:  2010-06       Impact factor: 5.258

3.  Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995 to 2004.

Authors:  Pradeep Y Ramulu; Kevin J Corcoran; Suzanne L Corcoran; Alan L Robin
Journal:  Ophthalmology       Date:  2007-04-27       Impact factor: 12.079

4.  The Ahmed Versus Baerveldt study: one-year treatment outcomes.

Authors:  Panos G Christakis; Jeffrey W Kalenak; David Zurakowski; James C Tsai; Jeffrey A Kammer; Paul J Harasymowycz; Iqbal I K Ahmed
Journal:  Ophthalmology       Date:  2011-09-01       Impact factor: 12.079

5.  Surface topographies of glaucoma drainage devices and their influence on human tenon fibroblast adhesion.

Authors:  Lars Choritz; Kaloian Koynov; Giulia Renieri; Keith Barton; Norbert Pfeiffer; Hagen Thieme
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-03-05       Impact factor: 4.799

6.  Effectiveness of nonocclusive ligature and fenestration used in Baerveldt aqueous shunts for early postoperative intraocular pressure control.

Authors:  Sukesh Kansal; Marlene R Moster; David Kim; Courtland M Schmidt; Richard P Wilson; L Jay Katz
Journal:  J Glaucoma       Date:  2002-02       Impact factor: 2.503

7.  Practice preferences for glaucoma surgery: a survey of the American Glaucoma Society in 2008.

Authors:  Manishi A Desai; Steven J Gedde; William J Feuer; Wei Shi; Philip P Chen; Richard K Parrish
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2011 May-Jun

Review 8.  Glaucoma drainage devices: a systematic literature review and current controversies.

Authors:  Chian-Huey Hong; Analisa Arosemena; David Zurakowski; Ramesh S Ayyala
Journal:  Surv Ophthalmol       Date:  2005 Jan-Feb       Impact factor: 6.048

9.  2002 survey of the American Glaucoma Society: practice preferences for glaucoma surgery and antifibrotic use.

Authors:  Anand B Joshi; Richard K Parrish; William F Feuer
Journal:  J Glaucoma       Date:  2005-04       Impact factor: 2.503

10.  Tube fenestrations in Baerveldt Glaucoma Implant surgery: 1-year results compared with standard implant surgery.

Authors:  Geoffrey T Emerick; Steven J Gedde; Donald L Budenz
Journal:  J Glaucoma       Date:  2002-08       Impact factor: 2.503