Literature DB >> 31330200

Novel technologies for heart rate assessment during neonatal resuscitation at birth - A systematic review.

Peter A Johnson1, Po-Yin Cheung1, Tze-Fun Lee1, Megan O'Reilly1, Georg M Schmölzer2.   

Abstract

BACKGROUND: 6.5-9 million newborns worldwide require resuscitation at birth annually. During neonatal resuscitation, inaccurate or slow heart rate (HR) assessments may significantly increase risk of infant mortality or morbidity. Therefore fast, accurate, and effective HR assessment tools are critical for neonatal resuscitation.
OBJECTIVE: To systematically review the literature about accuracy, latency, and efficacy of technologies for HR assessment during neonatal resuscitation.
METHODS: Adhering to PRISMA guidelines, PubMed, EMBASE, and Google Scholar databases were systematically searched to identify studies related to technologies for HR assessment, which could be used to guide neonatal resuscitation.
RESULTS: Forty-six studies evaluating HR assessment technologies for neonatal resuscitation were identified. In total, 16 studies (3/16 randomized trials and 13/16 observational studies) compared two or more HR assessment technologies to measure accuracy, latency, and efficacy. Of the trials, 1/3 had a low risk of bias while 2/3 had high risks. All observational studies had high risks of bias. Most studies considered infants not requiring resuscitation, constituting indirect evidence and lower certainty in the context of neonatal resuscitation. Two trials reported faster times to HR assessment using electrocardiogram with a mean(SD) 66(20) versus 114(39) s and a median(IQR) 24(19-39) versus 48(36-69) s (both p < 0.001), compared to pulse oximetry.
CONCLUSION: While electrocardiography is faster to assess HR at birth and more reliable to detect HR changes compared to other recommended technologies, practice should not exclusively rely on ECG. While novel technologies could support HR assessment, no studies validate their clinical efficacy during neonatal resuscitation.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Delivery room; Heart rate assessment; Infants; Neonatal resuscitation; Newborn

Year:  2019        PMID: 31330200     DOI: 10.1016/j.resuscitation.2019.07.018

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  9 in total

1.  Smartphone app for neonatal heart rate assessment: an observational study.

Authors:  Susanna Myrnerts Höök; Nicolas J Pejovic; Francesco Cavallin; Clare Lubulwa; Josaphat Byamugisha; Jolly Nankunda; Thorkild Tylleskär; Tobias Alfven
Journal:  BMJ Paediatr Open       Date:  2020-07-22

2.  Characterisation of Textile Embedded Electrodes for Use in a Neonatal Smart Mattress Electrocardiography System.

Authors:  Henry Dore; Rodrigo Aviles-Espinosa; Zhenhua Luo; Oana Anton; Heike Rabe; Elizabeth Rendon-Morales
Journal:  Sensors (Basel)       Date:  2021-02-02       Impact factor: 3.576

3.  Neonatal Resuscitation in Children 2021: Focus on Training, Technology, and New Clinical Approaches.

Authors:  Daniele Trevisanuto; Viraraghavan Vadakkencherry Ramaswamy; Paolo Ernesto Villani
Journal:  Children (Basel)       Date:  2022-02-01

4.  Contactless heart rate measurement in newborn infants using a multimodal 3D camera system.

Authors:  Libor Svoboda; Jan Sperrhake; Maria Nisser; Chen Zhang; Gunter Notni; Hans Proquitté
Journal:  Front Pediatr       Date:  2022-08-09       Impact factor: 3.569

5.  Comparing pulse rate measurement in newborns using conventional and dry-electrode ECG monitors.

Authors:  Eris van Twist; Hylke H Salverda; Arjan B Te Pas
Journal:  Acta Paediatr       Date:  2022-01-31       Impact factor: 4.056

Review 6.  [Newborn resuscitation and support of transition of infants at birth].

Authors:  John Madar; Charles C Roehr; Sean Ainsworth; Hege Ersda; Colin Morley; Mario Rüdiger; Christiane Skåre; Tomasz Szczapa; Arjan Te Pas; Daniele Trevisanuto; Berndt Urlesberger; Dominic Wilkinson; Jonathan P Wyllie
Journal:  Notf Rett Med       Date:  2021-06-02       Impact factor: 0.892

7.  Evaluation of a Tap-Based Smartphone App for Heart Rate Assessment During Asphyxia in a Porcine Model of Neonatal Resuscitation.

Authors:  Peter A Johnson; Nicolò Morina; Megan O'Reilly; Tze-Fun Lee; Po-Yin Cheung; Georg M Schmölzer
Journal:  Front Pediatr       Date:  2019-11-05       Impact factor: 3.418

8.  Doppler Ultrasound for Heart Rate Assessment in a Porcine Model of Neonatal Asphyxia.

Authors:  Nicolò Morina; Peter A Johnson; Megan O'Reilly; Tze-Fun Lee; Maryna Yaskina; Po-Yin Cheung; Georg M Schmölzer
Journal:  Front Pediatr       Date:  2020-01-31       Impact factor: 3.418

9.  Comparison of Heart Rate Feedback from Dry-Electrode ECG, 3-Lead ECG, and Pulse Oximetry during Newborn Resuscitation.

Authors:  Siren Rettedal; Joar Eilevstjønn; Amalie Kibsgaard; Jan Terje Kvaløy; Hege Ersdal
Journal:  Children (Basel)       Date:  2021-11-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.