Characterisation of Textile Embedded Electrodes for Use in a Neonatal Smart Mattress Electrocardiography System.

Henry Dore1, Rodrigo Aviles-Espinosa1, Zhenhua Luo2, Oana Anton3, Heike Rabe3, Elizabeth Rendon-Morales1.   

Abstract

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.

Entities:  

Keywords:  electric potential sensor; electrocardiogram; electrode; medical devices; textile; wearables

Mesh:

Year:  2021        PMID: 33540669      PMCID: PMC7867279          DOI: 10.3390/s21030999

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  26 in total

1.  PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals.

Authors:  A L Goldberger; L A Amaral; L Glass; J M Hausdorff; P C Ivanov; R G Mark; J E Mietus; G B Moody; C K Peng; H E Stanley
Journal:  Circulation       Date:  2000-06-13       Impact factor: 29.690

2.  European Resuscitation Council Guidelines for Resuscitation 2015: Section 7. Resuscitation and support of transition of babies at birth.

Authors:  Jonathan Wyllie; Jos Bruinenberg; Charles Christoph Roehr; Mario Rüdiger; Daniele Trevisanuto; Berndt Urlesberger
Journal:  Resuscitation       Date:  2015-10-15       Impact factor: 5.262

Review 3.  Part 7: Neonatal Resuscitation: 2015 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations.

Authors:  Jeffrey M Perlman; Jonathan Wyllie; John Kattwinkel; Myra H Wyckoff; Khalid Aziz; Ruth Guinsburg; Han-Suk Kim; Helen G Liley; Lindsay Mildenhall; Wendy M Simon; Edgardo Szyld; Masanori Tamura; Sithembiso Velaphi
Journal:  Circulation       Date:  2015-10-20       Impact factor: 29.690

4.  Heartbeat detection using energy thresholding and template match.

Authors:  H L Chan; G U Chen; M A Lin; S C Fang
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

5.  Electrical characteristics of conductive yarns and textile electrodes for medical applications.

Authors:  Linda Rattfält; Maria Lindén; Peter Hult; Lena Berglin; Per Ask
Journal:  Med Biol Eng Comput       Date:  2007-10-10       Impact factor: 2.602

6.  Pulse oximetry measures a lower heart rate at birth compared with electrocardiography.

Authors:  Jeroen J van Vonderen; Stuart B Hooper; Jacco K Kroese; Arno A W Roest; Ilona C Narayen; Erik W van Zwet; Arjan B te Pas
Journal:  J Pediatr       Date:  2014-10-14       Impact factor: 4.406

7.  Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms.

Authors:  G D Clifford; J Behar; Q Li; I Rezek
Journal:  Physiol Meas       Date:  2012-08-17       Impact factor: 2.833

8.  Normal Newborn Heart Rate in the First Five Minutes of Life Assessed by Dry-Electrode Electrocardiography.

Authors:  Jørgen Erland Linde; Jörn Schulz; Jeffrey M Perlman; Knut Øymar; Fortunata Francis; Joar Eilevstjønn; Hege Langli Ersdal
Journal:  Neonatology       Date:  2016-06-02       Impact factor: 4.035

9.  The Apgar score has survived the test of time.

Authors:  Mieczyslaw Finster; Margaret Wood
Journal:  Anesthesiology       Date:  2005-04       Impact factor: 7.892

10.  Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter.

Authors:  Q Li; R G Mark; G D Clifford
Journal:  Physiol Meas       Date:  2007-12-10       Impact factor: 2.833

View more
  1 in total

Review 1.  Smart Electronic Textiles for Wearable Sensing and Display.

Authors:  Seungse Cho; Taehoo Chang; Tianhao Yu; Chi Hwan Lee
Journal:  Biosensors (Basel)       Date:  2022-04-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.