Literature DB >> 3131843

A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapy.

M van Herk1, H Meertens.   

Abstract

It is very important to have a daily verification of patient setup during radiotherapy. Therefore, we have developed an on-line imaging device for high energy photons. It consists of a matrix of 128 x 128 liquid filled ionisation chambers and has a field of view of 320 mm x 320 mm. This device has an extremely flat cassette-like housing for easy handling and for application with existing radiotherapy equipment. A dedicated microcomputer is used to measure the currents of the 16384 ionisation chambers at high speed. The same computer is used to restore and process the images. With an imaging time of 3.1 s, an image quality comparable to film is obtained. Images of high and low contrast phantoms and of patients are presented. With this device, high quality portal images will be available within only a few seconds after the start of the treatment. This allows an almost instantaneous decision on the approval of patient setup. In addition, it enables observation of organ or patient motion during a single treatment. Analysis of these images at high speed will be an interesting new area of research.

Entities:  

Mesh:

Year:  1988        PMID: 3131843     DOI: 10.1016/0167-8140(88)90208-3

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  6 in total

1.  Digital contrast enhancement for online portal imaging.

Authors:  K W Leszczynski; S Shalev
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

2.  Verification of quality parameters for portal images in radiotherapy.

Authors:  Csilla Pesznyák; István Polgár; Csaba Weisz; Réka Király; Pál Zaránd
Journal:  Radiol Oncol       Date:  2010-12-31       Impact factor: 2.991

3.  Third party EPID with IGRT capability retrofitted onto an existing medical linear accelerator.

Authors:  D O Odero; D S Shimm
Journal:  Biomed Imaging Interv J       Date:  2009-07-01

4.  Evaluation of relative transmitted dose for a step and shoot head and neck intensity modulated radiation therapy using a scanning liquid ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak
Journal:  J Med Phys       Date:  2012-01

5.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

6.  Dosimetric Validation of Digital Megavolt Imager for Flattening Filter Free Beams in the Pre-Treatment Quality Assurance of Stereotactic Body Radiation Therapy for Liver Metastases.

Authors:  Vendhan Subramani; Murali Rathakrishnan; Arunai Nambiraj N; Saraswathi Chitra S; Murali Venkatraman
Journal:  Asian Pac J Cancer Prev       Date:  2020-06-01
  6 in total