Literature DB >> 31289736

Cement leakage into the hip joint during TFN-A cement augmentation in a revision surgery of an extra-capsular hip fracture.

Lionel Llano1, Fernando Diaz-Dilernia1, Danilo Taype1, Carlos Sancineto1, Jorge Barla1, Guido Carabelli1.   

Abstract

INTRODUCTION: The intra-articular migration of the spiral lamina or screw, after close reduction and internal fixation (CRIF) with an intramedullary cervicodiaphyseal nail (cut-through), is one of the most frequent postoperative complications. We present a patient with a cut-through and cement leakage into the hip joint after TFN-A cement augmentation and spiral lamina replacement.
METHODS: A 83-year-old man, suffered a cut-through after CRIF of his left extracapsular hip fracture during the third postoperative month. A revision surgery was planned, including spiral lamina replacement and cement augmentation. Cement leakage into the hip joint was confirmed in the immediate postoperative radiograph and a new intervention was indicated with the removal of the third bodies.
RESULTS: The patient presented good clinical evolution, without functional limitation or pain. In routinely postoperative radiographic controls, no differences were observed respect to the immediate postoperative one. DISCUSSION: Current literature dealing with implant revision surgery and associated cement augmentation are scarce.
CONCLUSION: As far as we are concerned, this is the first case in the literature of a re-revision surgery of an extracapsular hip fracture due to a three months postoperative cut-through and a posterior cement leakage into the hip joint after TFN-A cement augmentation and spiral lamina replacement with the need of a posterolateral approach for removal.

Entities:  

Keywords:  Cement augmentation; Cut through; Extracapsular hip fracture; Nail revision surgery

Year:  2019        PMID: 31289736      PMCID: PMC6593312          DOI: 10.1016/j.tcr.2019.100212

Source DB:  PubMed          Journal:  Trauma Case Rep        ISSN: 2352-6440


Introduction

The intra-articular migration of the spiral lamina or screw, after close reduction and internal fixation (CRIF) with an intra-medullary nail (cut-through), is one of the most frequent postoperative complications for the treatment of pertrochanteric fractures [1,2]. Multiple treatment options have been proposed, such as blade replacement [3], the cement augmentation technique [1], and total hip arthroplasty [4]. We present a patient with a cut-through and cement leakage into the hip joint after TFN-A cement augmentation and spiral lamina replacement.

Methods

A 83-year-old male was referred to our emergency unit due to a low energy fall. Physical examination revealed an externally rotated, abducted and shortened leg with severe pain on his left hip. CRIF was performed on the first day after admission. Postoperative recovery was uneventful and the patient was discharged at the 3rd day after surgery. After 3 months of being discharged, the patient was readmitted during routinely postoperative control at our clinic. He complained of severe hip pain and impossibility for weight bearing. Radiographs and a CT-scan were indicated. Intra-articular cephalic spiral lamina migration was evidenced (Fig. 1A, B, 2A, B and C). A revision surgery was planned, including the spiral lamina replacement and cement augmentation due to poor bone stock quality.
Fig. 1

Anteroposterior (A) and Lateral (B) radiographs of the hip showing the cut-through of the cephalic screw.

Fig. 2

Computed Tomography Scan. Coronal (A), axial (B) and sagittal (C) that certify the intra-articular migration of the screw.

Anteroposterior (A) and Lateral (B) radiographs of the hip showing the cut-through of the cephalic screw. Computed Tomography Scan. Coronal (A), axial (B) and sagittal (C) that certify the intra-articular migration of the screw. A polypropylene mesh was introduced into the femoral head to prevent cement leakage. Hip joint surface integrity was reassured through contrast injection and intraoperative radioscopic control. After cephalic spiral lamina revision and during augmentation, a cement leakage was observed and contrasted with the injected radiopaque solution (Fig. 3, A and B). In the immediate postoperative radiographic control, the presence of intraarticular cement was confirmed (Fig. 4).
Fig. 3

(A): Intraoperative radioscopic control where there is no evidence of contrast leakage. (B): Control after augmentation where it seems to be intraarticular cement leakage.

Fig. 4

Immediate postoperative radiographic control. Anteroposterior (A) and lateral (B) views where intraarticular cement leak is observed.

(A): Intraoperative radioscopic control where there is no evidence of contrast leakage. (B): Control after augmentation where it seems to be intraarticular cement leakage. Immediate postoperative radiographic control. Anteroposterior (A) and lateral (B) views where intraarticular cement leak is observed. A new intervention was indicated and a posterolateral approach was performed, followed by a meticulous capsulotomy of the joint and direct observation of the migrated material (Fig. 5). The foreign body was in intimal contact with the hip loading area and was successfully extracted. As a consequence, an additional osteochondral lesion of the femoral head was also identified without other associated labral or acetabulum lesions. Finally, profuse irrigation and meticulous closure of the joint capsule was performed (Fig. 6).
Fig. 5

(A): Intraoperative images during the extraction procedure. (B): Foreign body extracted.

Fig. 6

Immediate postoperative radiographic control. Anterolateral (A) and lateral (B) views after posterolateral approach.

(A): Intraoperative images during the extraction procedure. (B): Foreign body extracted. Immediate postoperative radiographic control. Anterolateral (A) and lateral (B) views after posterolateral approach.

Results

In the immediate postoperative period, the weight bearing of the affected limb was restricted for 48 h. Partial and full weight bearing was indicated progressively as tolerated. Postoperative recovery was uneventful and the patient was discharged at the 4th postoperative day. Routinely postoperative controls were done as expected on the outpatient clinic. During the 12 successive months the patient was monitored on an outpatient basis. He presented good clinical evolution, without functional limitation and absence of pain. At latest follow-up, the Harris Hip score (HHS) was 86 points (range, 0–100 points). In routinely radiographic controls no differences were observed respect to the immediate postoperative control of the last surgical procedure and a proper consolidation of the fracture was achieved (Fig. 7).
Fig. 7

12 months follow up radiographic control.

12 months follow up radiographic control.

Discussion

Cut-through is one of the most frequent complications associated with the use of cervical-diaphyseal intramedullary nails for the treatment of pertrocanteric hip fractures. The axial migration of the cephalic component of the implant (cut-out) [1,2] was also widely reported in the literature. However, these complications are rare in relation to the totality of procedures performed, being 1.9% as reported by different authors [[5], [6], [7], [8]]. Some authors propose the cement augmentation of the spiral lamina to improve the anchorage in case of patients with osteoporotic bone [[9], [10], [11]]. Scola et al. reported a case of a cut-out treated with revision of the spiral lamina and cement augmentation, with poor outcome and the patient's death 4 weeks postoperatively [3]. However, current literature dealing with implant revision surgery and associated cement augmentation are scarce. Hanke et al. developed a technique for cement leakage prevention during augmentation, placing a plug at the subchondral level inside the femoral head, similar to the one used during cementation in hip arthroplasty [12]. However, this technique was described in experimental cadaveric models without osteoporosis or associated osteochondral defects in the femoral head. Brunner et al. reported 28 cases of cut-through treated with different salvage procedures. Sixteen where treated with lamina exchange without augmentation, 6 with lamina exchange and cement augmentation and the remaining 6 with total hip replacement (THR). From the group of 16, 8 of them failed and needed a new surgery. In the augmentation group, 2 of them failed and needed a new surgery too. On the other hand, none of the patients treated with THR needed a new surgical procedure [13]. In our particular case, we think the cement augmentation was the most appropriate technique considering the age of the patient and the bone stock quality. Performing only the lag screw exchange would be insufficient considering the femoral head osteochondral lesion. On the other hand, a suitable mechanism to prevent cement leakage should have been applied instead of a polypropylene mesh, such as an autologous bone graft or a plug as Hanke et al. have described.

Conclusion

The cement augmentation of the spiral lamina or the cephalic screw is a technique described for the treatment of extracapsular hip fractures in patients with osteoporosis, and for cases when a revision surgery, such as a cut-through, is indicated. Intraoperative radioscopic control and contrast injection during surgery are essential to avoid a possible leakage of intra-articular cement. As far as we are concerned, this is the first case in the literature of a re-revision surgery of an extracapsular hip fracture due to a three months postoperative cut-through and a posterior cement leakage into the hip joint after TFN-A cement augmentation and spiral lamina replacement with the need of a posterolateral approach for removal.

Declaration of Competing Interest

Each author certifies that he or she has no commercial associations (e.g., consultancies, stock ownership, equity interest, and patent/licensing arrangements) that might pose a conflict of interest in connection with the submitted paper.
  13 in total

1.  Forward progression of the helical blade into the pelvis after repair with the Trochanter Fixation Nail (TFN).

Authors:  Matthew A Frank; Richard S Yoon; Praveen Yalamanchili; Edward W Choung; Frank A Liporace
Journal:  J Orthop Trauma       Date:  2011-10       Impact factor: 2.512

2.  Reason and treatment of failure of proximal femoral nail antirotation internal fixation for femoral intertrochanteric fractures of senile patients.

Authors:  J J Liu; L C Shan; B Y Deng; J G Wang; W Zhu; Z D Cai
Journal:  Genet Mol Res       Date:  2014-08-07

3.  Biomechanical effect of bone cement augmentation on rotational stability and pull-out strength of the Proximal Femur Nail Antirotation™.

Authors:  S Erhart; W Schmoelz; M Blauth; A Lenich
Journal:  Injury       Date:  2011-05-23       Impact factor: 2.586

4.  Mechanical complications of intertrochanteric hip fractures treated with trochanteric femoral nails.

Authors:  Wanjun Liu; Dongsheng Zhou; Fang Liu; Michael J Weaver; Mark S Vrahas
Journal:  J Trauma Acute Care Surg       Date:  2013-08       Impact factor: 3.313

5.  Is augmentation a possible salvage procedure after lateral migration of the proximal femur nail antirotation?

Authors:  S Erhart; C Kammerlander; R El-Attal; W Schmoelz
Journal:  Arch Orthop Trauma Surg       Date:  2012-07-03       Impact factor: 3.067

6.  Long-term results of the augmented PFNA: a prospective multicenter trial.

Authors:  C Kammerlander; H Doshi; F Gebhard; A Scola; C Meier; W Linhart; M Garcia-Alonso; J Nistal; M Blauth
Journal:  Arch Orthop Trauma Surg       Date:  2013-12-03       Impact factor: 3.067

7.  The PFNA proximal femur nail in treatment of unstable proximal femur fractures--3 cases of postoperative perforation of the helical blade into the hip joint.

Authors:  Alexander Brunner; Jens Arne Jöckel; Reto Babst
Journal:  J Orthop Trauma       Date:  2008 Nov-Dec       Impact factor: 2.512

8.  Results of proximal femur nail antirotation for low velocity trochanteric fractures in elderly.

Authors:  Ashok Sunil Gavaskar; Muthukumar Subramanian; Naveen Chowdary Tummala
Journal:  Indian J Orthop       Date:  2012-09       Impact factor: 1.251

9.  The PFNA® Augmented in Revision Surgery of Proximal Femur Fractures.

Authors:  Alexander Scola; Florian Gebhard; Christoph Dehner; Götz Röderer
Journal:  Open Orthop J       Date:  2014-07-11

10.  Comparison of proximal femoral nail antirotation (PFNA) with AO dynamic condylar screws (DCS) for the treatment for unstable peritrochanteric femoral fractures.

Authors:  Emrah Kemal Sahin; Ahmet Imerci; Hakan Kınık; Levent Karapınar; Umut Canbek; Ahmet Savran
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.