Image reconstruction for interrupted-beam x-ray CT on diagnostic clinical scanners.

Matthew J Muckley1, Baiyu Chen, Thomas Vahle, Thomas O'Donnell, Florian Knoll, Aaron D Sodickson, Daniel K Sodickson, Ricardo Otazo.   

Abstract

Low-dose x-ray CT is a major research area with high clinical impact. Compressed sensing using view-based sparse sampling and sparsity-promoting regularization has shown promise in simulations, but these methods can be difficult to implement on diagnostic clinical CT scanners since the x-ray beam cannot be switched on and off rapidly enough. An alternative to view-based sparse sampling is interrupted-beam sparse sampling. SparseCT is a recently-proposed interrupted-beam scheme that achieves sparse sampling by blocking a portion of the beam using a multislit collimator (MSC). The use of an MSC necessitates a number of modifications to the standard compressed sensing reconstruction pipeline. In particular, we find that SparseCT reconstruction is feasible within a model-based image reconstruction framework that incorporates data fidelity weighting to consider penumbra effects and source jittering to consider the effect of partial source obstruction. Here, we present these modifications and demonstrate their application in simulations and real-world prototype scans. In simulations compared to conventional low-dose acquisitions, SparseCT is able to achieve smaller normalized root-mean square differences and higher structural similarity measures on two reduction factors. In prototype experiments, we successfully apply our reconstruction modifications and maintain image resolution at quarter-dose reduction level. The SparseCT design requires only small hardware modifications to current diagnostic clinical scanners, opening up new possibilities for CT dose reduction.

Entities:  

Mesh:

Year:  2019        PMID: 31258151      PMCID: PMC6927037          DOI: 10.1088/1361-6560/ab2df1

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Improved compressed sensing-based cone-beam CT reconstruction using adaptive prior image constraints.

Authors:  Ho Lee; Lei Xing; Ran Davidi; Ruijiang Li; Jianguo Qian; Rena Lee
Journal:  Phys Med Biol       Date:  2012-03-30       Impact factor: 3.609

2.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

3.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

4.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

5.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

6.  SparseCT: System concept and design of multislit collimators.

Authors:  Baiyu Chen; Erich Kobler; Matthew J Muckley; Aaron D Sodickson; Thomas O'Donnell; Thomas Flohr; Bernhard Schmidt; Daniel K Sodickson; Ricardo Otazo
Journal:  Med Phys       Date:  2019-05-06       Impact factor: 4.071

7.  Joint reconstruction of multi-channel, spectral CT data via constrained total nuclear variation minimization.

Authors:  David S Rigie; Patrick J La Rivière
Journal:  Phys Med Biol       Date:  2015-02-06       Impact factor: 3.609

8.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

9.  Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge.

Authors:  Cynthia H McCollough; Adam C Bartley; Rickey E Carter; Baiyu Chen; Tammy A Drees; Phillip Edwards; David R Holmes; Alice E Huang; Farhana Khan; Shuai Leng; Kyle L McMillan; Gregory J Michalak; Kristina M Nunez; Lifeng Yu; Joel G Fletcher
Journal:  Med Phys       Date:  2017-10       Impact factor: 4.071

10.  Low-dose and scatter-free cone-beam CT imaging using a stationary beam blocker in a single scan: phantom studies.

Authors:  Xue Dong; Michael Petrongolo; Tianye Niu; Lei Zhu
Journal:  Comput Math Methods Med       Date:  2013-11-20       Impact factor: 2.238

View more
  1 in total

1.  Multiorientation Simultaneous Computation of Back-Projection CT Image Reconstruction Algorithm in Staging Diagnosis of Bladder Cancer.

Authors:  Kaiyan Hu; Jianping Zhu; Pei Li; Lili Ying
Journal:  Comput Math Methods Med       Date:  2022-06-28       Impact factor: 2.809

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.