Literature DB >> 31226704

Real-time intrafraction motion monitoring in external beam radiotherapy.

Jenny Bertholet1, Antje Knopf, Björn Eiben, Jamie McClelland, Alexander Grimwood, Emma Harris, Martin Menten, Per Poulsen, Doan Trang Nguyen, Paul Keall, Uwe Oelfke.   

Abstract

Radiotherapy (RT) aims to deliver a spatially conformal dose of radiation to tumours while maximizing the dose sparing to healthy tissues. However, the internal patient anatomy is constantly moving due to respiratory, cardiac, gastrointestinal and urinary activity. The long term goal of the RT community to 'see what we treat, as we treat' and to act on this information instantaneously has resulted in rapid technological innovation. Specialized treatment machines, such as robotic or gimbal-steered linear accelerators (linac) with in-room imaging suites, have been developed specifically for real-time treatment adaptation. Additional equipment, such as stereoscopic kilovoltage (kV) imaging, ultrasound transducers and electromagnetic transponders, has been developed for intrafraction motion monitoring on conventional linacs. Magnetic resonance imaging (MRI) has been integrated with cobalt treatment units and more recently with linacs. In addition to hardware innovation, software development has played a substantial role in the development of motion monitoring methods based on respiratory motion surrogates and planar kV or Megavoltage (MV) imaging that is available on standard equipped linacs. In this paper, we review and compare the different intrafraction motion monitoring methods proposed in the literature and demonstrated in real-time on clinical data as well as their possible future developments. We then discuss general considerations on validation and quality assurance for clinical implementation. Besides photon RT, particle therapy is increasingly used to treat moving targets. However, transferring motion monitoring technologies from linacs to particle beam lines presents substantial challenges. Lessons learned from the implementation of real-time intrafraction monitoring for photon RT will be used as a basis to discuss the implementation of these methods for particle RT.

Entities:  

Mesh:

Year:  2019        PMID: 31226704     DOI: 10.1088/1361-6560/ab2ba8

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  35 in total

1.  Fiducial marker migration following computed tomography-guided placement in the liver: a case report.

Authors:  Karishma Khullar; Survandita Tara Dhawan; John Nosher; Salma K Jabbour
Journal:  AME Case Rep       Date:  2021-04-25

2.  A method to reconstruct intra-fractional liver motion in rotational radiotherapy using linear fiducial markers.

Authors:  Yujie Chi; Chenyang Shen; Bin Li; You Zhang; Ming Yang; Michael Folkert; Xun Jia
Journal:  Phys Med Biol       Date:  2019-11-21       Impact factor: 3.609

3.  Automatic liver tumor localization using deep learning-based liver boundary motion estimation and biomechanical modeling (DL-Bio).

Authors:  Hua-Chieh Shao; Xiaokun Huang; Michael R Folkert; Jing Wang; You Zhang
Journal:  Med Phys       Date:  2021-11-19       Impact factor: 4.071

4.  Real-time liver tumor localization via a single x-ray projection using deep graph neural network-assisted biomechanical modeling.

Authors:  Hua-Chieh Shao; Jing Wang; Ti Bai; Jaehee Chun; Justin C Park; Steve Jiang; You Zhang
Journal:  Phys Med Biol       Date:  2022-05-24       Impact factor: 4.174

5.  Technical Note: Evaluation of audiovisual biofeedback smartphone application for respiratory monitoring in radiation oncology.

Authors:  Dante P I Capaldi; Tomi F Nano; Hao Zhang; Lawrie B Skinner; Lei Xing
Journal:  Med Phys       Date:  2020-10-10       Impact factor: 4.071

6.  3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom.

Authors:  Charles K Matrosic; Wesley Culberson; Andrew Shepard; Sydney Jupitz; Bryan Bednarz
Journal:  Phys Med       Date:  2021-04-23       Impact factor: 2.685

Review 7.  A narrative review of MRI acquisition for MR-guided-radiotherapy in prostate cancer.

Authors:  Jing Yuan; Darren M C Poon; Gladys Lo; Oi Lei Wong; Kin Yin Cheung; Siu Ki Yu
Journal:  Quant Imaging Med Surg       Date:  2022-02

8.  First-in-human imaging using a MR-compatible e4D ultrasound probe for motion management of radiotherapy.

Authors:  Bryan P Bednarz; Sydney Jupitz; Warren Lee; David Mills; Heather Chan; Timothy Fiorillo; James Sabitini; David Shoudy; Aqsa Patel; Jhimli Mitra; Shourya Sarcar; Bo Wang; Andrew Shepard; Charles Matrosic; James Holmes; Wesley Culberson; Michael Bassetti; Patrick Hill; Alan McMillan; James Zagzebski; L Scott Smith; Thomas K Foo
Journal:  Phys Med       Date:  2021-07-01       Impact factor: 3.119

9.  Markerless Real-Time 3-Dimensional kV Tracking of Lung Tumors During Free Breathing Stereotactic Radiation Therapy.

Authors:  Kimmie de Bruin; Max Dahele; Hassan Mostafavi; Berend J Slotman; Wilko F A R Verbakel
Journal:  Adv Radiat Oncol       Date:  2021-04-20

10.  Factors affecting accuracy and precision in ultrasound guided radiotherapy.

Authors:  Alexander Grimwood; Karen Thomas; Sally Kember; Georgina Aldis; Rebekah Lawes; Beverley Brigden; Jane Francis; Emer Henegan; Melanie Kerner; Louise Delacroix; Alexandra Gordon; Alison Tree; Emma J Harris; Helen A McNair
Journal:  Phys Imaging Radiat Oncol       Date:  2021-05-29
View more