Literature DB >> 34632589

Automatic liver tumor localization using deep learning-based liver boundary motion estimation and biomechanical modeling (DL-Bio).

Hua-Chieh Shao1, Xiaokun Huang1, Michael R Folkert1, Jing Wang1, You Zhang1.   

Abstract

PURPOSE: Recently, two-dimensional-to-three-dimensional (2D-3D) deformable registration has been applied to deform liver tumor contours from prior reference images onto estimated cone-beam computed tomography (CBCT) target images to automate on-board tumor localizations. Biomechanical modeling has also been introduced to fine-tune the intra-liver deformation-vector-fields (DVFs) solved by 2D-3D deformable registration, especially at low-contrast regions, using tissue elasticity information and liver boundary DVFs. However, the caudal liver boundary shows low contrast from surrounding tissues in the cone-beam projections, which degrades the accuracy of the intensity-based 2D-3D deformable registration there and results in less accurate boundary conditions for biomechanical modeling. We developed a deep-learning (DL)-based method to optimize the liver boundary DVFs after 2D-3D deformable registration to further improve the accuracy of subsequent biomechanical modeling and liver tumor localization.
METHODS: The DL-based network was built based on the U-Net architecture. The network was trained in a supervised fashion to learn motion correlation between cranial and caudal liver boundaries to optimize the liver boundary DVFs. Inputs of the network had three channels, and each channel featured the 3D DVFs estimated by the 2D-3D deformable registration along one Cartesian direction (x, y, z). To incorporate patient-specific liver boundary information into the DVFs, the DVFs were masked by a liver boundary ring structure generated from the liver contour of the prior reference image. The network outputs were the optimized DVFs along the liver boundary with higher accuracy. From these optimized DVFs, boundary conditions were extracted for biomechanical modeling to further optimize the solution of intra-liver tumor motion. We evaluated the method using 34 liver cancer patient cases, with 24 for training and 10 for testing. We evaluated and compared the performance of three methods: 2D-3D deformable registration, 2D-3D-Bio (2D-3D deformable registration with biomechanical modeling), and DL-Bio (DL model prediction with biomechanical modeling). The tumor localization errors were quantified through calculating the center-of-mass-errors (COMEs), DICE coefficients, and Hausdorff distance between deformed liver tumor contours and manually segmented "gold-standard" contours.
RESULTS: The predicted DVFs by the DL model showed improved accuracy at the liver boundary, which translated into more accurate liver tumor localizations through biomechanical modeling. On a total of 90 evaluated images and tumor contours, the average (± sd) liver tumor COMEs of the 2D-3D, 2D-3D-Bio, and DL-Bio techniques were 4.7 ± 1.9 mm, 2.9 ± 1.0 mm, and 1.7 ± 0.4 mm. The corresponding average (± sd) DICE coefficients were 0.60 ± 0.12, 0.71 ± 0.07, and 0.78 ± 0.03; and the average (± sd) Hausdorff distances were 7.0 ± 2.6 mm, 5.4 ± 1.5 mm, and 4.5 ± 1.3 mm, respectively.
CONCLUSION: DL-Bio solves a general correlation model to improve the accuracy of the DVFs at the liver boundary. With improved boundary conditions, the accuracy of biomechanical modeling can be further increased for accurate intra-liver low-contrast tumor localization.
© 2021 American Association of Physicists in Medicine.

Entities:  

Keywords:  CBCT; biomechanical modeling; convolutional neural network; deep learning; deformable registration; liver

Mesh:

Year:  2021        PMID: 34632589      PMCID: PMC8678353          DOI: 10.1002/mp.15275

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  65 in total

1.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

2.  Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids.

Authors:  Lei Ren; Yingxuan Chen; You Zhang; William Giles; Jianyue Jin; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2015-05-24

3.  Technical note: MLC-tracking performance on the Elekta unity MRI-linac.

Authors:  M Glitzner; P L Woodhead; P T S Borman; J J W Lagendijk; B W Raaymakers
Journal:  Phys Med Biol       Date:  2019-08-01       Impact factor: 3.609

4.  Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Authors:  Xi Chen; Luo Ouyang; Hao Yan; Xun Jia; Bin Li; Qingwen Lyu; You Zhang; Jing Wang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

5.  An adversarial machine learning framework and biomechanical model-guided approach for computing 3D lung tissue elasticity from end-expiration 3DCT.

Authors:  Anand P Santhanam; Brad Stiehl; Michael Lauria; Katelyn Hasse; Igor Barjaktarevic; Jonathan Goldin; Daniel A Low
Journal:  Med Phys       Date:  2020-12-22       Impact factor: 4.071

6.  A biomechanical modeling-guided simultaneous motion estimation and image reconstruction technique (SMEIR-Bio) for 4D-CBCT reconstruction.

Authors:  Xiaokun Huang; You Zhang; Jing Wang
Journal:  Phys Med Biol       Date:  2018-02-08       Impact factor: 3.609

7.  Development and clinical evaluation of a three-dimensional cone-beam computed tomography estimation method using a deformation field map.

Authors:  Lei Ren; Indrin J Chetty; Junan Zhang; Jian-Yue Jin; Q Jackie Wu; Hui Yan; David M Brizel; W Robert Lee; Benjamin Movsas; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-04-07       Impact factor: 7.038

8.  Stereotactic body radiation therapy for colorectal liver metastases.

Authors:  A E M van der Pool; A Méndez Romero; W Wunderink; B J Heijmen; P C Levendag; C Verhoef; J N M Ijzermans
Journal:  Br J Surg       Date:  2010-03       Impact factor: 6.939

9.  Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy.

Authors:  Hiroki Shirato; Toshiyuki Harada; Tooru Harabayashi; Kazutoshi Hida; Hideho Endo; Kei Kitamura; Rikiya Onimaru; Koichi Yamazaki; Nobuaki Kurauchi; Tadashi Shimizu; Nobuo Shinohara; Michiaki Matsushita; Hirotoshi Dosaka-Akita; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

10.  Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters.

Authors:  Joubin Nasehi Tehrani; Yin Yang; Rene Werner; Wei Lu; Daniel Low; Xiaohu Guo; Jing Wang
Journal:  Phys Med Biol       Date:  2015-11-04       Impact factor: 3.609

View more
  1 in total

1.  Real-time liver tumor localization via a single x-ray projection using deep graph neural network-assisted biomechanical modeling.

Authors:  Hua-Chieh Shao; Jing Wang; Ti Bai; Jaehee Chun; Justin C Park; Steve Jiang; You Zhang
Journal:  Phys Med Biol       Date:  2022-05-24       Impact factor: 4.174

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.