Literature DB >> 31217149

Comparison of cardiac computed tomography angiography and transoesophageal echocardiography for device surveillance after left atrial appendage closure.

Sadia R Qamar1, Sabeena Jalal, Savvas Nicolaou, Michael Tsang, Thomas Gilhofer, Jacqueline Saw.   

Abstract

AIMS: Device surveillance after left atrial appendage (LAA) closure (LAAC) is important to assess device positioning, peri-device leak (PDL) and device-related thrombus (DRT). There are limited data on the role of cardiac CT angiography (CCTA) after LAAC. We therefore sought to compare CCTA to transoesophageal echocardiography (TEE) in patients who successfully underwent LAAC. METHODS AND
RESULTS: We report our consecutive series of non-valvular atrial fibrillation patients who underwent LAAC and had CCTA and TEE post LAAC. Prospective cardiac-gated CCTA was performed with the Toshiba 320-detector or Siemens second-generation 128-slice dual-source scanner, and post-processing was performed with IMPAX 3D reformats. Glomerular filtration rate <30 mL/min/1.73 m² was an exclusion for CCTA. Device positioning, PDL or fabric leak, ratio of left atrial (LA) to LAA linear attenuation coefficient, and DRT were analysed. One hundred and two patients underwent LAAC (79 WATCHMAN, 17 Amulet, 6 ACP). Mean age was 76.4±7.5 years, CHADS2 score 3.0±1.3, and CHADS-VASc score 4.6±1.6. CCTA was performed at a mean of 105.2±54.8 days, and TEE at a mean of 124.9±100.3 days post LAAC. LAA patency was observed in 52/100 (52%), with 45 (86.5%) via PDL and seven (13.5%) through fabric leak. Linear attenuation coefficient <100 HU and LA:LAA ratio <0.25 were seen in occluded devices. PDL was only observed in 35/102 (34.3%) on TEE. Mean device compression was greater with sealed devices (11.3±4.3% versus 8.2±4.0%, p<0.001). There was only one DRT, which was observed on both TEE and CCTA.
CONCLUSIONS: CCTA is a suitable alternative to TEE for device surveillance post LAAC. CCTA was more sensitive than TEE for assessing PDL and can delineate the cause of residual LAA contrast patency.

Entities:  

Mesh:

Year:  2019        PMID: 31217149     DOI: 10.4244/EIJ-D-18-01107

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  13 in total

Review 1.  Computed tomography measurement for left atrial appendage closure.

Authors:  Masahiko Asami
Journal:  Cardiovasc Interv Ther       Date:  2022-03-20

Review 2.  The Role of Cardiac Computed Tomography in Heart Failure.

Authors:  Spencer S Kitchin; Venkat Sanjay Manubolu; Sion K Roy; Matthew J Budoff
Journal:  Curr Heart Fail Rep       Date:  2022-05-19

3.  Design and Rationale of the Swiss-Apero Randomized Clinical Trial: Comparison of Amplatzer Amulet vs Watchman Device in Patients Undergoing Left Atrial Appendage Closure.

Authors:  Roberto Galea; Federico De Marco; Adel Aminian; Nicolas Meneveau; Frederic Anselme; Christoph Gräni; Adrian T Huber; Emmanuel Teiger; Xavier Iriart; Marco Angelillis; Nicolas Brugger; Alessandro Spirito; Noé Corpataux; Anna Franzone; Pascal Vranckx; Urs Fischer; Giovanni Pedrazzini; Francesco Bedogni; Stephan Windecker; Lorenz Räber; Marco Valgimigli
Journal:  J Cardiovasc Transl Res       Date:  2021-04-21       Impact factor: 4.132

4.  Reduced plasma level of basic fibroblast growth factor is associated with incomplete device endothelialization at six months following left atrial appendage closure.

Authors:  Jing Xu; Xin Gong; Chuanzhi Chen; Jun Xing; Qi Wang; Weifeng Shen; Qi Zhang
Journal:  BMC Cardiovasc Disord       Date:  2021-05-16       Impact factor: 2.298

5.  Device neo-endothelialization after left atrial appendage closure: the role of cardiac computed tomography angiography.

Authors:  Roberto Galea; Christoph Gräni
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-17       Impact factor: 2.357

6.  Necessity of 45-Day Transesophageal Echocardiography After the WATCHMAN Procedure Amid the COVID-19 Pandemic.

Authors:  Bryan E-Xin Tan; Jeremiah P Depta; Bipul Baibhav; Deepak L Bhatt
Journal:  JACC Cardiovasc Imaging       Date:  2020-05-26

7.  Occlusion of Bilobulated Left Atrial Appendage Using the Dual-Watchman Technique: A Long-Term Follow-Up Study.

Authors:  Tao Chen; Qing-Song Wang; Ge Liu; Xu Lu; Ting-Ting Song; Ming-Yuan Shi; Hang Zhu; Yang Mu; Jun Guo; Yun-Dai Chen
Journal:  Front Cardiovasc Med       Date:  2022-03-22

8.  A Comparative Study of Three Imaging Modalities for Size Selection of a Watchman Left Atrial Appendage Closure Device.

Authors:  Zhong-Bao Ruan; Fei Wang; Ge-Cai Chen; Li Zhu
Journal:  Yonsei Med J       Date:  2022-04       Impact factor: 2.759

9.  Value of detecting peri-device leak and incomplete endothelialization by cardiac CT angiography in atrial fibrillation patients post Watchman LAAC combined with radiofrequency ablation.

Authors:  Ming-Zhe Zhao; Run-Min Chi; Ying Yu; Qun-Shan Wang; Jian Sun; Wei Li; Peng-Pai Zhang; Bo Liu; Xiang-Fei Feng; Yan Zhao; Bin-Feng Mo; Mu Chen; Rui Zhang; Chang-Qi Gong; Yi-Chi Yu; Yi-Gang Li
Journal:  J Cardiovasc Electrophysiol       Date:  2021-09-01       Impact factor: 2.942

Review 10.  Combination of ablation and left atrial appendage closure as "One-stop" procedure in the treatment of atrial fibrillation: Current status and future perspective.

Authors:  Ben He; Li-Sheng Jiang; Zi-Yong Hao; Hao Wang; Yu-Tong Miao
Journal:  Pacing Clin Electrophysiol       Date:  2021-03-09       Impact factor: 1.976

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.