Combined transcutaneous oxygen, carbon dioxide tensions and end-expired CO2 levels in severely ill newborns.

W B Geven1, E Nagler, T de Boo, W Lemmens.   

Abstract

In 12 newborns combined transcutaneous PO2 and PCO2 levels were measured by means of a Sensor Medics Transend Transcutaneous Gas System simultaneously with the end-tidal PCO2 (PetCo2) values using an Angström Eliza CO2 analyzer. Although the individual correlation coefficients differed greatly, the diagnostic sensitivity of PtcO2 and PtcCO2 was satisfactory within specified limits. The PetCO2 did not agree well with the PaCO2 due to physiologic factors related to lung disorders. We conclude that PtcO2 and PtcCO2 values are very useful in monitoring severely ill newborns although arterial blood gas measurements remain necessary, but not as often as when the transcutaneous technique is not used.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3118653     DOI: 10.1007/978-1-4613-1927-6_21

Source DB:  PubMed          Journal:  Adv Exp Med Biol        ISSN: 0065-2598            Impact factor:   2.622


  6 in total

Review 1.  Are carbon dioxide detectors useful in neonates?

Authors:  E J Molloy; K Deakins
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-07       Impact factor: 5.747

2.  End tidal carbon dioxide monitoring--its reliability in neonates.

Authors:  S Nangia; A Saili; A K Dutta
Journal:  Indian J Pediatr       Date:  1997 May-Jun       Impact factor: 1.967

3.  A survey of transcutaneous blood gas monitoring among European neonatal intensive care units.

Authors:  Mario Rüdiger; Kerstin Töpfer; Hannes Hammer; Gerd Schmalisch; Roland R Wauer
Journal:  BMC Pediatr       Date:  2005-08-10       Impact factor: 2.125

4.  Agreement of Mixed Venous Carbon Dioxide Tension (PvCO2) and Transcutaneous Carbon Dioxide (PtCO2) Measurements in Ventilated Infants.

Authors:  Sinan Uslu; Ali Bulbul; Mesut Dursun; Umut Zubarioglu; Ebru Turkoglu; Omer Guran
Journal:  Iran J Pediatr       Date:  2015-01-19       Impact factor: 0.364

5.  Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants.

Authors:  Marie Janaillac; Sonia Labarinas; Riccardo E Pfister; Oliver Karam
Journal:  Crit Care Res Pract       Date:  2016-06-08

Review 6.  Non-invasive carbon dioxide monitoring in neonates: methods, benefits, and pitfalls.

Authors:  Deepika Sankaran; Lida Zeinali; Sameeia Iqbal; Praveen Chandrasekharan; Satyan Lakshminrusimha
Journal:  J Perinatol       Date:  2021-06-19       Impact factor: 2.521

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.