Literature DB >> 31179742

Effect of Metacarpal Fixation Configuration on Strength and Fracture Gap Displacements in a Cadaveric Model of Externally Fixed Distal Radius Fractures.

Kenneth F Taylor1, Jyoti Sharma1, Neena A Davisson1, Evan P Roush1, Christine M Jones1, Gregory S Lewis1.   

Abstract

Background: The purpose of the study was to determine the biomechanical effect of distal pin configuration in unilateral external fixation of distal radius fracture in a cadaveric model.
Methods: A standardized 2-part extra-articular distal radius fracture model with dorsal comminution was created in 6 matched pairs of cadaveric upper extremities. Specimens within each matched pair were randomly assigned to either 4 or 6 cortices of distal pin metacarpal fixation. Cyclic, compressive loads were applied to the palmar hand.
Results: No significant differences were detected in maximum forces. Six-cortex metacarpal fixation showed significantly lower magnitude of actuator displacement at 100 N cyclic loading. The difference in construct stiffness did not translate to disparities in angular and translational interfragmentary displacement at the fracture gap. Conclusions: Utilizing only 4 cortices and sparing the middle finger metacarpal avoids the need for a more transverse orientation required with 6-cortex fixation, which may otherwise impede thumb motion.

Entities:  

Keywords:  basic science; biomechanics; cadaveric model; diagnosis; distal radius; external fixation; fracture/dislocation; pin configuration

Mesh:

Year:  2019        PMID: 31179742      PMCID: PMC8041428          DOI: 10.1177/1558944719851231

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  18 in total

1.  Outcome after surgery of distal radius fractures: no differences between external fixation and ORIF.

Authors:  Thomas Westphal; Stefan Piatek; Stephan Schubert; Stephan Winckler
Journal:  Arch Orthop Trauma Surg       Date:  2005-10-22       Impact factor: 3.067

Review 2.  Biomechanics and biology of external fixation of distal radius fractures.

Authors:  Randy R Bindra
Journal:  Hand Clin       Date:  2005-08       Impact factor: 1.907

3.  Mechanical performance of pin clamps in external fixators.

Authors:  H T Aro; T J Hein; E Y Chao
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

4.  A biomechanical comparison of different wrist external fixators with and without K-wire augmentation.

Authors:  S W Wolfe; G Austin; M Lorenze; C R Swigart; M M Panjabi
Journal:  J Hand Surg Am       Date:  1999-05       Impact factor: 2.230

5.  Bending stiffness of unilateral and bilateral fixator frames.

Authors:  F Behrens; W D Johnson; T W Koch; N Kovacevic
Journal:  Clin Orthop Relat Res       Date:  1983-09       Impact factor: 4.176

6.  Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation.

Authors:  Thomas W Wright; Marybeth Horodyski; Dean W Smith
Journal:  J Hand Surg Am       Date:  2005-03       Impact factor: 2.230

7.  Intraarticular fractures of the distal radius: a cadaveric study to determine if ligamentotaxis restores radiopalmar tilt.

Authors:  R A Bartosh; M J Saldana
Journal:  J Hand Surg Am       Date:  1990-01       Impact factor: 2.230

8.  Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence?

Authors:  Kenneth J Koval; John J Harrast; Jeffrey O Anglen; James N Weinstein
Journal:  J Bone Joint Surg Am       Date:  2008-09       Impact factor: 5.284

9.  Biomechanical analysis of pin placement and pin size for external fixation of distal radius fractures.

Authors:  W H Seitz; A I Froimson; D B Brooks; P D Postak; R D Parker; J M LaPorte; A S Greenwald
Journal:  Clin Orthop Relat Res       Date:  1990-02       Impact factor: 4.176

10.  Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial.

Authors:  K Egol; M Walsh; N Tejwani; T McLaurin; C Wynn; N Paksima
Journal:  J Bone Joint Surg Br       Date:  2008-09
View more