Literature DB >> 10357530

A biomechanical comparison of different wrist external fixators with and without K-wire augmentation.

S W Wolfe1, G Austin, M Lorenze, C R Swigart, M M Panjabi.   

Abstract

To compare stability of wrist external fixation, simulated unstable extra-articular distal radius fractures were created in 7 fresh-frozen cadaveric upper extremities and stabilized using 4 different external fixators. Physiologic muscle tension across the wrist was simulated by application of 40-N load distributed among the wrist tendons. Alternating loads of up to 100 N in flexion and extension of the wrist were applied during stability testing and 3-dimensional kinematics of the proximal and distal fracture fragments were determined using attached infrared light-emitting diodes and a 3-dimensional motion tracking system. Fracture stability was reassessed for each of the constructs after augmentation of the fracture fragments with a single dorsal transfixion K-wire. K-wire augmentation demonstrated a significant reduction in motion of the distal radial fragment of at least 40% in all 3 rotational planes. For flexion/extension, the reduction in motion was from 4.5 degrees to 2.6 degrees. For radial/ulnar deviation, the range of motion decreased from 3.0 degrees to 1.5 degrees. Rotational motion declined from an average of 3.2 degrees to 1.2 degrees. The addition of the single dorsal transfixion K-wire significantly improved stability of each of the 4 fixators in at least 1 of the 3 planes in which motion was measured. While we compared the most rigid with some of the least rigid external fixators, the data do not support an important difference in fracture fragment stability among the 4 fixators. The data much more strongly support the concept of K-wire augmentation for increasing stability of an unstable extra-articular distal radius fracture regardless of the type of external fixator that is used.

Entities:  

Mesh:

Year:  1999        PMID: 10357530     DOI: 10.1053/jhsu.1999.0516

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  9 in total

1.  Efficiency of fragment specific fixation plates in the treatment of comminuted distal radial fractures.

Authors:  Elhadi Musaab Elhadi Babikir; Eyad Daood Al-Maqdassy; Khalid Hasan; Shamsi Abdul Hameed; Abduljabbar Alhammoud; Mohammed Mubarak Al-Ateeq Al-Dosari
Journal:  Int Orthop       Date:  2017-06-27       Impact factor: 3.075

2.  External fixation with or without supplementary intramedullary Kirschner wires in the treatment of distal radial fractures.

Authors:  Charles Lin; Jui-Sheng Sun; Sheng-Mou Hou
Journal:  Can J Surg       Date:  2004-12       Impact factor: 2.089

3.  Effect of Metacarpal Fixation Configuration on Strength and Fracture Gap Displacements in a Cadaveric Model of Externally Fixed Distal Radius Fractures.

Authors:  Kenneth F Taylor; Jyoti Sharma; Neena A Davisson; Evan P Roush; Christine M Jones; Gregory S Lewis
Journal:  Hand (N Y)       Date:  2019-06-10

Review 4.  Stabilization and treatment of Colles' fractures in elderly patients.

Authors:  William G Blakeney
Journal:  Clin Interv Aging       Date:  2010-11-18       Impact factor: 4.458

5.  Aspects of current management of distal radius fractures in the elderly individuals.

Authors:  Rohit Arora; Markus Gabl; Stefanie Erhart; Gernot Schmidle; Christian Dallapozza; Martin Lutz
Journal:  Geriatr Orthop Surg Rehabil       Date:  2011-09

6.  Can Radiocarpal-Spanning Fixation Be Made More Functional by Placing the Wrist in Extension? A Biomechanical Study Under Physiologic Loads.

Authors:  Tobias Mann; Daniel J Lee; Jason Dahl; John C Elfar
Journal:  Geriatr Orthop Surg Rehabil       Date:  2016-03

7.  Mechanical advantages of a truss-structure-based fracture fixation system--a novel fracture fixation device "PinFix".

Authors:  Tetsuya Arai; Michiro Yamamoto; Katsuyuki Iwatsuki; Tadahiro Natsume; Takaaki Shinohara; Masahiro Tatebe; Shigeru Kurimoto; Hideyuki Ota; Shuichi Kato; Hitoshi Hirata
Journal:  Nagoya J Med Sci       Date:  2013-08       Impact factor: 1.131

8.  Randomized clinical trial on percutaneous minimally invasive osteosynthesis of fractures of the distal extremity of the radius.

Authors:  Marcio Aurélio Aita; Carlos Henrique Vieira Ferreira; Daniel Schneider Ibanez; Rafael Saraiva Marquez; Douglas Hideki Ikeuti; Rodrigo Toledo Mota; Marcos Vinicius Credidio; Edison Noboru Fujiki
Journal:  Rev Bras Ortop       Date:  2014-04-18

9.  Early hybrid nonbridging external fixation of unstable distal radius fractures in patients aged ≥50 years.

Authors:  Pengfei Cheng; Fan Wu; Hua Chen; Chaoyin Jiang; Ting Wang; Pei Han; Yimin Chai
Journal:  J Int Med Res       Date:  2019-12-23       Impact factor: 1.671

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.