Akihito Igarashi1, Kimiya Shimizu2, Sayaka Kato2, Kazutaka Kamiya3. 1. Sanno Hospital Eye Center, Tokyo, Japan. Electronic address: iki0478@yahoo.co.jp. 2. Sanno Hospital Eye Center, Tokyo, Japan. 3. Department of Ophthalmology, University of Kitasato School of Medicine, Kanagawa, Japan.
Abstract
PURPOSE: To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT). SETTING: Sanno Hospital, Tokyo, Japan. DESIGN: Retrospective case series. METHODS: Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept-source AS-OCT CASIA2 system. RESULTS: The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), -6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance (r = 0.27, P = .08). CONCLUSION: The ATA measurements had higher reproducibility than the WTW measurements on AS-OCT, making it is a more important predictor of postoperative vault.
PURPOSE: To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT). SETTING: Sanno Hospital, Tokyo, Japan. DESIGN: Retrospective case series. METHODS: Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept-source AS-OCT CASIA2 system. RESULTS: The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), -6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance (r = 0.27, P = .08). CONCLUSION: The ATA measurements had higher reproducibility than the WTW measurements on AS-OCT, making it is a more important predictor of postoperative vault.
Authors: Elena Martínez-Plaza; Alberto López-Miguel; Alberto López-de la Rosa; Miguel J Maldonado Journal: Int Ophthalmol Date: 2022-10-19 Impact factor: 2.029
Authors: Soraya M R Jonker; Tos T J M Berendschot; Isabelle E Y Saelens; Noël J C Bauer; Rudy M M A Nuijts Journal: Indian J Ophthalmol Date: 2020-12 Impact factor: 1.848
Authors: Eun Min Kang; Ik Hee Ryu; Geunyoung Lee; Jin Kuk Kim; In Sik Lee; Ga Hee Jeon; Hojin Song; Kazutaka Kamiya; Tae Keun Yoo Journal: Transl Vis Sci Technol Date: 2021-05-03 Impact factor: 3.283