Literature DB >> 31174990

Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography.

Akihito Igarashi1, Kimiya Shimizu2, Sayaka Kato2, Kazutaka Kamiya3.   

Abstract

PURPOSE: To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT).
SETTING: Sanno Hospital, Tokyo, Japan.
DESIGN: Retrospective case series.
METHODS: Eyes were observed for 3 months after hole ICL implantation for myopia or myopic astigmatism. Central vault, ATA, and WTW measurements were obtained before and after surgery using the swept-source AS-OCT CASIA2 system.
RESULTS: The study included 44 eyes (23 patients). The mean patient age and preoperative spherical equivalent, ATA, and WTW values were 36.2 years ± 8.8 (SD), -6.23 ± 3.41 diopters (D), 12.03 ± 0.40 mm, and 11.72 ± 0.40 mm, respectively. The safety index and efficacy index 3 months postoperatively were 1.13 ± 0.21 and 0.91 ± 0.30, respectively. Regarding predictability, 93.2% of eyes were within ±0.50 D of the attempted correction and all eyes were within ±1.00 D. The reproducibility coefficients for the ATA distance and WTW distance were 0.998 and 0.960, respectively. The mean postoperative central vault was 491.6 ± 189.5 μm. There was a significant correlation between postoperative vault and the ICL size and ATA distance (Spearman rank correlation coefficient r = 0.59, P < .001) but not between the ICL size and WTW distance (r = 0.27, P = .08).
CONCLUSION: The ATA measurements had higher reproducibility than the WTW measurements on AS-OCT, making it is a more important predictor of postoperative vault.
Copyright © 2019 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2019        PMID: 31174990     DOI: 10.1016/j.jcrs.2019.02.020

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  14 in total

1.  Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness.

Authors:  Xuepei Li; Yijing Zhou; Charlotte Aimee Young; Aiming Chen; Guangming Jin; Danying Zheng
Journal:  Ann Transl Med       Date:  2020-07

2.  Inter-eye and postoperative prediction of vault after implantation of EVO + Visian phakic implantable collamer lens.

Authors:  Elena Martínez-Plaza; Alberto López-Miguel; Alberto López-de la Rosa; Miguel J Maldonado
Journal:  Int Ophthalmol       Date:  2022-10-19       Impact factor: 2.029

3.  Clinical Observation of Corneal Endothelial Plaques With Fungal and Bacterial Keratitis by Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy.

Authors:  Xin Jin; Hao Jin; Yan Shi; Nan Zhang; Hong Zhang
Journal:  Cornea       Date:  2021-11-10       Impact factor: 3.152

4.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

5.  Phakic intraocular lens: Getting the right size.

Authors:  Kalyaani Deshpande; Rushad Shroff; Partha Biswas; Kamal Kapur; Naren Shetty; Ann Sarah Koshy; Pooja Khamar
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

Review 6.  Phakic intraocular lenses: An overview.

Authors:  Soraya M R Jonker; Tos T J M Berendschot; Isabelle E Y Saelens; Noël J C Bauer; Rudy M M A Nuijts
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

7.  Correlation between intraoperative and postoperative vaulting of the EVO implantable Collamer lens: a retrospective study of real-time observations of vaulting using the RESCAN 700 system.

Authors:  Nian Guan; Xiao-Nong Zhang; Wan-Jun Zhang
Journal:  BMC Ophthalmol       Date:  2022-01-03       Impact factor: 2.209

8.  Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens.

Authors:  Yuki Takagi; Takashi Kojima; Tomoya Nishida; Tomoaki Nakamura; Kazuo Ichikawa
Journal:  PLoS One       Date:  2020-11-16       Impact factor: 3.240

9.  Assessment of low-vault cases with an implantable collamer lens.

Authors:  Sayaka Kato; Kimiya Shimizu; Akihito Igarashi
Journal:  PLoS One       Date:  2020-11-04       Impact factor: 3.240

10.  Development of a Web-Based Ensemble Machine Learning Application to Select the Optimal Size of Posterior Chamber Phakic Intraocular Lens.

Authors:  Eun Min Kang; Ik Hee Ryu; Geunyoung Lee; Jin Kuk Kim; In Sik Lee; Ga Hee Jeon; Hojin Song; Kazutaka Kamiya; Tae Keun Yoo
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.