Literature DB >> 3115445

Accuracy of auscultatory blood pressure measurement with a long cuff.

G A van Montfrans1, G M van der Hoeven, J M Karemaker, W Wieling, A J Dunning.   

Abstract

Intra-arterial blood pressure was compared with simultaneous auscultatory measurements in 37 subjects with a wide range of blood pressures and arm circumferences; six cuffs of various lengths and widths were used. Nineteen subjects had an arm circumference of 34 cm or more (mean 40 cm) and the other 18 were considered to be non-obese and had a mean arm circumference of 30 cm. With each larger cuff, in terms of bladder surface area, auscultatory blood pressure decreased a few mm relative to intra-arterial pressure both for systolic and for diastolic measurements. Apart from diastolic pressure measured with the two 12 cm wide cuffs (12 X 23 cm, 12 X 30 cm) in the obese group all other auscultatory measurements differed less than 5% from intra-arterial pressure, albeit with considerable variability among the subjects. The differences in error among measurements with the four largest cuffs in the obese group (13 X 30 cm, 14 X 30 cm, 14 X 38 cm, and a conical cuff) were clinically irrelevant, and there was even less to choose among all six cuffs in the non-obese subjects. These results suggest that auscultatory blood pressure may be measured with acceptable accuracy with a single long bladdered cuff both in subjects with large arms and in subjects with normal sized arms.

Entities:  

Mesh:

Year:  1987        PMID: 3115445      PMCID: PMC1247210          DOI: 10.1136/bmj.295.6594.354

Source DB:  PubMed          Journal:  Br Med J (Clin Res Ed)        ISSN: 0267-0623


  3 in total

1.  Recommendations on blood pressure measurement.

Authors:  J C Petrie; E T O'Brien; W A Littler; M de Swiet
Journal:  Br Med J (Clin Res Ed)       Date:  1986-09-06

2.  The next 30 years--will the progress continue?

Authors:  R S Ross
Journal:  Circulation       Date:  1980-07       Impact factor: 29.690

3.  Accuracy of auscultatory blood pressure measurements in hypertensive and obese subjects.

Authors:  P E Nielsen; B Larsen; P Holstein; H L Poulsen
Journal:  Hypertension       Date:  1983 Jan-Feb       Impact factor: 10.190

  3 in total
  12 in total

1.  Continuous finger arterial pressure: utility in the cardiovascular laboratory.

Authors:  B P Imholz; W Wieling; G J Langewouters; G A van Montfrans
Journal:  Clin Auton Res       Date:  1991-03       Impact factor: 4.435

2.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01

3.  Relaxation therapy and continuous ambulatory blood pressure in mild hypertension: a controlled study.

Authors:  G A van Montfrans; J M Karemaker; W Wieling; A J Dunning
Journal:  BMJ       Date:  1990-05-26

4.  Blood pressure measurement in pregnancy: the effect of arm circumference and sphygmomanometer cuff size.

Authors:  Chye L Kho; Mark A Brown; Sharon L H Ong; George J Mangos
Journal:  Obstet Med       Date:  2009-09-01

Review 5.  Home Blood Pressure Monitoring.

Authors:  Jacob George; Thomas MacDonald
Journal:  Eur Cardiol       Date:  2015-12

6.  Catheter-manometer system damped blood pressures detected by neural nets.

Authors:  A Prentza; K H Wesseling
Journal:  Med Biol Eng Comput       Date:  1995-07       Impact factor: 2.602

7.  Evaluation of non-invasive blood pressure measurement by the Finapres method at rest and during dynamic exercise in subjects with cardiovascular insufficiency.

Authors:  B Silke; J P Spiers; S Boyd; E Graham; G McParland; M E Scott
Journal:  Clin Auton Res       Date:  1994-04       Impact factor: 4.435

Review 8.  Principles and techniques of blood pressure measurement.

Authors:  Gbenga Ogedegbe; Thomas Pickering
Journal:  Cardiol Clin       Date:  2010-11       Impact factor: 2.213

9.  Confounders of auscultatory blood pressure measurement.

Authors:  R H Baker; J Ende
Journal:  J Gen Intern Med       Date:  1995-04       Impact factor: 5.128

10.  Blood pressure measurement in adults: large cuffs for all?

Authors:  P R Croft; J K Cruickshank
Journal:  J Epidemiol Community Health       Date:  1990-06       Impact factor: 3.710