INTRODUCTION: To evaluate long-term outcomes following stand-alone implantation of two second-generation trabecular micro-bypass stents (iStent inject®, Glaukos Corp., San Clemente, CA, USA) in eyes with predominantly primary open-angle glaucoma (POAG) and considerable preoperative disease burden.
METHODS: Eyes with POAG, pseudoexfoliative glaucoma (PXG), appositional narrow-angle glaucoma (NAG, with open-angle configuration in the area of implantation), or secondary glaucoma were included in this prospective, non-randomized, consecutive case series. All eyes underwent ab interno iStent inject implantation as a sole procedure. Assessments through 36 months included IOP, medications, corrected distance visual acuity (CDVA), secondary glaucoma surgeries, and complications and adverse events.
RESULTS: Two iStent inject stents were implanted in 44 consecutive eyes (POAG = 38, PXG = 4, appositional NAG = 1, secondary neovascular glaucoma = 1) of 31 patients, and 33 eyes had 36-month follow-up data. Preoperative mean IOP was 25.3 ± 6.0 mmHg on a mean of 2.98 ± 0.88 medications, with 75% of eyes on 3-5 medications, no eyes medication-free, and 50% of eyes with history of prior glaucoma surgery. At 36 months postoperatively, mean IOP reduced by 42% to 14.6 ± 2.0 mmHg (p < 0.0001) and 87.9% of eyes achieved an IOP reduction of ≥ 20% versus preoperatively. In addition, 97% of eyes reached IOP ≤ 18 mmHg (vs. 9.1% preoperatively; p < 0.0001) and 70.0% of eyes reached IOP ≤ 15 mmHg (vs. 2.3% preoperatively; p < 0.0001). Mean medication burden decreased by 82% to 0.55 ± 0.79 (p < 0.0001), and 61% of eyes became medication-free. All eyes maintained or decreased their 36-month medication burden versus preoperatively. Safety was favorable, including minimal adverse events and stable CDVA through 36 months postoperatively.
CONCLUSION: This real-world cohort of glaucomatous eyes with substantial preoperative disease burden experienced significant, sustained, safe IOP and medication reductions through 36 months following stand-alone iStent inject implantation. FUNDING: Article processing charges and writing assistance were provided by Glaukos Corp. (San Clemente, CA, USA).

Entities:  

Keywords:  Glaucoma; IStent inject; Intraocular pressure; Medication; Microinvasive glaucoma surgery (MIGS); Second generation; Stand alone; Stent; Trabecular

Mesh:

Year:  2019        PMID: 31119690      PMCID: PMC6824385          DOI: 10.1007/s12325-019-00984-9

Source DB:  PubMed          Journal:  Adv Ther        ISSN: 0741-238X            Impact factor:   3.845


Introduction

Glaucoma consistently ranks as one of the leading causes of all blindness worldwide and is the single biggest cause of irreversible blindness [1, 2]. Population estimates reveal formidable numbers of patients affected by glaucoma, with rates increasing as life expectancies lengthen. To prevent visual deterioration and optic nerve damage, patients and their doctors initiate treatment, the cornerstone of which is the reduction of intraocular pressure (IOP). Medications typically are the first line of treatment, although their effectiveness is limited by local and systemic side effects, ocular surface damage, cost, complex dosing regimens, and suboptimal patient adherence [3-11]. Laser trabeculoplasty often is completed alongside or after medications, although it induces inflammation and its IOP-lowering impact has a limited time frame [12]. In later stages of the disease, traditional filtering surgeries such as tube shunt implantation or trabeculectomy are the main treatment modalities; however failure rates and long-term complications (e.g., endophthalmitis, hypotony, choroidal detachment, bleb leak, or infection) are a real concern [13-15]. If dramatic and immediate IOP reduction is needed, then these risks may be appropriate. However, for a large portion of the glaucoma population—particularly in eyes that need additional intervention beyond medication and/or lasers, but that do not yet warrant the risks of filtering surgery—a surgical treatment with a more favorable benefit-to-risk ratio may be preferable. Micro-invasive glaucoma surgery (MIGS) offers such a treatment, as it has shown consistent reductions in IOP and medication burden, while also maintaining favorable long-term safety [16]. A sizable body of evidence has shown that the eyes benefiting from this treatment can include those with more moderate and severe stages of glaucoma as well as mild glaucoma; and they may include eyes with newly diagnosed, treatment-naive glaucoma, in addition to those that already tried (and failed) prior medications and/or laser procedures. The first MIGS implant was the iStent® Trabecular Micro-Bypass (Glaukos Corp., San Clemente, CA, USA; FDA 2012, CE 2004). To date, this device has amassed a sizable long-term evidence base regarding its safety and performance in eyes with open-angle glaucoma, in settings both with and without cataract surgery. Most studies of the device have assessed outcomes in mild to moderate glaucoma [17-27], but other patient populations increasingly have been the subject of evaluation, such as pseudoexfoliative glaucoma, severe or refractory glaucoma, or newly diagnosed, treatment-naïve glaucoma [28-33]. Another growing and relevant area of investigation has been economics outcomes research [34-39], which consistently has shown favorable cost-effectiveness of the iStent in various healthcare models around the world. The newest US FDA-approved device in the MIGS treatment area is the second-generation iStent inject® Trabecular Micro-Bypass (Glaukos; FDA 2018, CE 2010), which includes two trabecular stents designed to reduce IOP by bolstering aqueous outflow through the trabecular meshwork into Schlemm’s canal (Figs. 1–2). In studies both with and without cataract surgery, and in both investigational and real-world settings, the ab interno-implanted iStent inject has demonstrated clinically significant reductions in IOP and medications over the long term [40-51]. These performance outcomes have been accompanied by favorable safety and a correspondingly advantageous benefit-to-risk profile.
Fig. 1

iStent inject® and iStent inject® Trabecular Micro-Bypass Stent System. Provided by Glaukos Corp.

Fig. 2

iStent inject® implantation: placement of two stents in the anterior chamber angle. Provided by Glaukos Corp.

iStent inject® and iStent inject® Trabecular Micro-Bypass Stent System. Provided by Glaukos Corp. iStent inject® implantation: placement of two stents in the anterior chamber angle. Provided by Glaukos Corp. In the present prospective cohort, we evaluate whether stand-alone second-generation trabecular bypass stent implantation is a durable, effective, and safe method to reduce IOP and medications in glaucomatous eyes with a substantial preoperative disease burden. This intervention was completed by a single surgeon within a real-world clinical setting and with a relatively long period of follow-up, providing relevant data to doctors and patients evaluating their glaucoma treatment options.

Methods

Study Design

This prospective, non-randomized, consecutive case series included eyes with various types of glaucoma that underwent implantation of two second-generation trabecular micro-bypass stents as a stand-alone procedure. One surgeon (F.H.) completed all surgeries during a 39-month period at an academic ophthalmology center in Heidelberg, Germany. Subjects were required to have glaucoma [including primary open-angle glaucoma (POAG), appositional narrow-angle glaucoma (NAG, defined as angle Shaffer grade 2, with an open angle in the area of stent implantation), pseudoexfoliative glaucoma (PXG), or secondary glaucoma], to be eligible for iStent inject surgery, and to have experienced glaucoma progression despite prior medical and/or surgical glaucoma treatment. Exclusion criteria included active intraocular inflammation, corneal and/or media opacities preventing the gonioscopic view, angle closure in the area of stent implantation, pregnancy, age < 18 years, or congenital glaucoma. Effectiveness outcomes consisted of IOP (3 measurements per time point, measured by Goldmann applanation) and topical ocular hypotensive medications. Baseline IOP was determined by IOP readings at two or more preoperative visits. Safety outcomes included CDVA, intraoperative and postoperative adverse events, and secondary surgical interventions. During the follow-up period, testing included visual fields every 6 months, OCT RNFL every 12 months, and optic nerve examination at every visit. Further surgical procedures were considered if visual field, OCT, or optic nerve findings were concerning for glaucoma progression and/or if IOP was inadequately reduced by iStent inject surgery (per surgeon discretion). All procedures performed were in accordance with the ethical standards of the institutional and/or national research committee [the Institutional Review Board (IRB) of the University of Heidelberg] and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. Informed consent was obtained from all individual participants included in the study. No clinical trial registration was required for the study. Patients have been followed through 36 months postoperatively, and follow-up is ongoing.

Stent Description, Surgical Technique, and Perioperative Medication

iStent inject implantation was completed as a sole procedure (i.e., without cataract surgery), using the standard implantation technique described previously [40, 43, 45]. In brief, the procedure consists of the following: after pupillary miosis and anterior chamber filling with a medium viscous ocular surgery viscoelastic device (OVD), the single-use, stainless steel injector is advanced through a temporal corneal incision to the nasal Schlemm’s canal, where two pre-loaded titanium stents are implanted ab interno approximately two clock-hours apart (Figs. 1–2). Each heparin-coated, 360 µm × 230-µm stent has a symmetric design (compatible with right or left eyes) and several lateral outlet lumens designed to decrease IOP by bolstering aqueous outflow from the anterior chamber to Schlemm’s canal. OVD is removed by bimanual irrigation and aspiration. After surgery, patients received 1 week of topical antibiotic (ciprofloxacin) and 4 weeks of topical anti-inflammatory medication (dexamethasone).

Data analyses

Descriptive statistics were used to summarize mean IOP and number of medications from the preoperative visit through 36 months postoperatively. Preoperative and 36-month proportional analyses were completed for percent of eyes with IOP ≤ 18 mmHg, IOP < 15 mmHg, and ≥ 20% IOP reduction; eyes on 0, 1, 2, or ≥ 3 medications; and eyes with reduced medications versus preoperatively. A paired t-test was used to compare preoperative versus month 36 mean IOP and number of medications, and the McNemar test was used to compare preoperative and month 36 proportional IOP outcomes.

Results

Subject Accountability, Demographics, and Preoperative Parameters

A total of 44 consecutive eyes of 31 patients were evaluated in this cohort, with glaucoma diagnoses including POAG (n = 38), PXG (n = 4), appositional NAG (n = 1), and secondary (neovascular) glaucoma (n = 1)(Table 1). Preoperative ocular parameters reflected a substantial disease burden. Mean medicated IOP was 25.3 ± 6.0 mmHg on a mean of 2.98 ± 0.88 medications, with 75% (33/44) of eyes on 3–5 glaucoma medications and no eyes medication-free. Average visual field mean deviation (VF MD) was – 6.4 dB, and mean C:D ratio was 0.8, with 73% of eyes (32/44) having a C:D ratio ≥ 0.8. Half of the eyes (22/44) had undergone a total of 35 glaucoma surgeries prior to iStent inject implantation.
Table 1

Demographics and preoperative characteristics (n = 44 eyes of 31 patients)

iStent inject (44 eyes)
Gender M/F23/21

Age (years)

Mean ± SD (range)

71.3 ± 10.5

(40–88)

Race100% Caucasian

 C:D ratio

 Mean ± SD (range)

0.8 ± 0.1

(0.5–1.0)

 VF MD (dB)

 Mean ± SD (range)

– 6.4 ± 6.9 dB

(− 24.4 to − 0.3)

Type of glaucoma n (%)

 POAG

 PXG

38 (86.4%)

4 (9.1%)

 Appositional narrow anglea1 (2.3%)
 Secondary (neovascular)1 (2.3%)
Mean medicated IOP (mmHg); mean ± SD25.3 ± 6.0 mmHg
Medicated IOP level (mmHg) n (%)
 ≤ 15 mmHg1 (2.3%)
 ≤ 18 mmHg4 (9.1%)
Mean # medications; mean ± SD2.98 ± 0.88
Eyes with prior glaucoma surgery n (%)22 (50.0%)
Prior glaucoma surgeries, n = 35 surgeriesb
 Trabeculectomy13
 CPC14
 ALT/SLT3
 Laser iridotomy2
 Single iStent1
 XEN implantation2
Eyes on 3–5 preoperative medications, n (%)33 (75%)

SD standard deviation, C:D cup to disc, VF MD visual field mean deviation, CPC cyclophotocoagulation, ALT argon laser trabeculoplasty, SLT selective laser trabeculoplasty

aEyes had open-angle configuration in the area of iStent inject implantation

bEyes could have more than one surgery (there were 35 surgeries in 22 eyes)

Demographics and preoperative characteristics (n = 44 eyes of 31 patients) Age (years) Mean ± SD (range) 71.3 ± 10.5 (40–88) C:D ratio Mean ± SD (range) 0.8 ± 0.1 (0.5–1.0) VF MD (dB) Mean ± SD (range) – 6.4 ± 6.9 dB (− 24.4 to − 0.3) POAG PXG 38 (86.4%) 4 (9.1%) SD standard deviation, C:D cup to disc, VF MD visual field mean deviation, CPC cyclophotocoagulation, ALT argon laser trabeculoplasty, SLT selective laser trabeculoplasty aEyes had open-angle configuration in the area of iStent inject implantation bEyes could have more than one surgery (there were 35 surgeries in 22 eyes)

Intraocular Pressure and Medication Use

At 36 months postoperatively, mean IOP reduced by 42% to 14.6 ± 2.0 mmHg (p < 0.0001) (Fig. 3), with 87.9% of eyes (29/33) decreasing IOP by ≥ 20% versus preoperatively. Nearly all eyes (97.0% or 32/33) achieved month 36 IOP ≤ 18 mmHg versus 9.1% (4/44) preoperatively (p < 0.0001) (Fig. 4), and 70.0% of eyes (23/33) achieved month 36 IOP ≤ 15 mmHg versus 2.3% (1/44) preoperatively (p < 0.0001). Mean number of medications decreased by 82% to 0.55 ± 0.79 (p < 0.0001)(Fig. 5). The per-patient medication impact at 36 months consisted of 61% of eyes (20/33) becoming medication-free (versus 0% preoperatively) and only 3.0% (1/33) on 3 medications versus 75% (33/44) on 3–5 medications preoperatively (Fig. 6). All eyes maintained or decreased their 36-month medication burden versus preoperatively.
Fig. 3

Reduction in mean intraocular pressure through 36 months (p < 0.0001); eyes with available data at each visit. IOP intraocular pressure, SD standard deviation, M month, Preop preoperative

Fig. 4

Proportional analysis of eyes with IOP ≤ 18 mmHg and ≤ 15 mmHg through 36 months*; eyes with available data at each visit. IOP intraocular pressure, M month, Preop preoperative. *Highly significant (p < 0.0001) increase in proportion of eyes with IOP ≤ 18 mmHg and IOP ≤ 15 mmHg at M36 vs. preoperatively

Fig. 5

Reduction in medication burden at 36 months vs. preoperative (p < 0.0001); eyes with available data at each visit. M month, Preop preoperative

Fig. 6

Proportional analysis of medication use through 36 months; eyes with available data at each visit. M month, Preop preoperative, Med medication

Reduction in mean intraocular pressure through 36 months (p < 0.0001); eyes with available data at each visit. IOP intraocular pressure, SD standard deviation, M month, Preop preoperative Proportional analysis of eyes with IOP ≤ 18 mmHg and ≤ 15 mmHg through 36 months*; eyes with available data at each visit. IOP intraocular pressure, M month, Preop preoperative. *Highly significant (p < 0.0001) increase in proportion of eyes with IOP ≤ 18 mmHg and IOP ≤ 15 mmHg at M36 vs. preoperatively Reduction in medication burden at 36 months vs. preoperative (p < 0.0001); eyes with available data at each visit. M month, Preop preoperative Proportional analysis of medication use through 36 months; eyes with available data at each visit. M month, Preop preoperative, Med medication

Safety

Successful implantation of two second-generation trabecular micro-bypass stents was completed in all eyes in this study. One eye had planned XEN explantation at the time of stent surgery, while all other eyes underwent stent implantation as a sole procedure. One intraoperative complication was reported, consisting of mild hyphema in the anterior chamber, which necessitated no intervention and resolved without sequelae by week 1. Postoperatively, all but four eyes had CDVA of 20/50 or better throughout follow-up (26/26 eyes at 12 months, 21/21 eyes at 24 months, and 30/30 eyes at 36 months postoperatively). The four eyes with CDVA worse than 20/50 had preexisting poor CDVA (ranging from 20/63 to 20/20,000 Snellen equivalent preoperatively). Ocular adverse events through 36 months postoperatively included two eyes of the same patient that had cataract progression starting at month 3 (CDVA remained at 20/40 or better in both eyes through 36 months) and one eye with uveitis at 24 months, which resolved without sequelae with 3 weeks of topical anti-inflammatory medication. Two eyes underwent additional glaucoma procedures at 1 month postoperatively (XEN implant and cyclophotocoagulation, respectively) because of the need for additional IOP reduction beyond what was achieved with iStent inject implantation (IOP had reduced to 14 mmHg ad 22 mmHg in the two eyes, respectively). No other secondary glaucoma surgeries or ocular adverse events occurred for the remainder of follow-up. In particular, there were no reports of hypotony, endophthalmitis, corneal complications, myopic shift, stent obstruction, peripheral anterior synechiae (PAS), or choroidal detachment.

Discussion

Three-year data from this prospective real-world cohort demonstrated safe, sustained, clinically and statistically significant reductions in IOP and medications in eyes with glaucoma after stand-alone iStent inject implantation. The preoperative disease burden in this patient cohort was sizable, with three-fourths of eyes on three or more medications, half of eyes with a history of prior glaucoma surgery, and moderate glaucomatous damage per VF MD and C:D ratio. Despite medications and/or surgery, however, mean preoperative IOP was > 25 mmHg, indicating the inability of such treatments to control the disease. It is noteworthy that iStent inject had a positive effect in these formerly treatment-resistant eyes. This treatment effect is consistent with prior studies showing benefit of this technology in various stages of glaucoma, from mild to advanced [40-51]. It also suggests that iStent inject may have a viable role in settings different from those typically considered for MIGS procedures: specifically, it may be considered not just in mild-to-moderate glaucoma as a primary surgery, but also in refractory eyes that have progressed despite previously undergoing more invasive surgery. This study assessed stand-alone stent implantation, thereby allowing the device’s treatment effects to be separated from those of phacoemulsification, which is known to reduce IOP to a modest degree in eyes with glaucoma [52-54]. Due to the stents alone, mean 36-month IOP showed a 42% decrease, a reduction consistent with those in previous studies of both combined and stand-alone iStent inject implantation [40-51]. The observation of comparable 36-month outcomes either with or without cataract surgery is not entirely surprising, since the IOP-reducing effect of cataract surgery is known to be temporary [52-54] and thus would be unlikely to persist through the month 36 visit. Compared with the previously published outcomes of the surgeon’s stent-cataract experience, in which IOP was reduced by 37% and medications were reduced by 68% [46], the IOP and medication reductions in this stand-alone cohort were slightly higher (42% and 82% reductions, respectively). Possible reasons for this difference include the higher preoperative IOP in the stand-alone cohort, as this is known to produce greater postoperative IOP reductions [27, 29]. The preoperative medication burden also was higher in the stand-alone cohort, which may predispose to greater reductions in medication number if the end goal is the same for a given patient (0 or 1 medication, for example). The difference also may reflect the surgeon’s learning curve, since the surgeon’s first cases were mostly combination surgeries (iStent inject + phaco), whereas most of his stand-alone cases were completed later in his experience with the device. A particularly meaningful end point is the significant increase in eyes achieving IOP ≤ 18 mmHg at 36 months (97.0% versus 9.1% preoperatively), as reaching this IOP threshold is known to be associated with a lessened visual field decline over the long term in patients with glaucoma [55]. Coincident with this IOP decrease, mean medication burden was reduced by nearly 2.5 medications (82% reduction), and all eyes had maintained or reduced antihypertensive medications versus their preoperative regimen. While no eyes were medication-free preoperatively, a majority (61%) were off all drops by 36 months postoperatively. While three-fourths of eyes were on 3–5 medications preoperatively, only one eye (3.0%) was on 3 medications at 36 months postoperatively. The benefits of medication reduction are myriad. It promotes treatment adherence, which has been shown to decrease dramatically when more than one eye drop is prescribed [5]. The ability to be off topical medications altogether is particularly advantageous, as considerable evidence has shown these medications to have toxic and pro-inflammatory effects on ocular surface cells [4, 10]. Medication reduction lessens the financial burden of glaucoma treatment, for both patients and government bodies funding healthcare. This financial impact has been the area of several informative cost-effectiveness analyses in recent years [34-39]. The clinical outcomes in the present study are consistent with those reported in these financial evaluations. Thus, although this study did not analyze economic effects specifically, it is reasonable to expect that improved IOP control and a 2.43-medication reduction could result in similar benefits as those cited in these cost-effectiveness studies: for example, lower medication costs and provider expenditures, reduced societal burden from visual impairment, improved medication adherence, fewer IOP-related complications, and fewer quality-adjusted life years lost by patients because of poor vision [34-39]. Finally, topical medication usage has long been reported to cause patient-reported ocular surface discomfort and objective ocular surface damage [4, 10, 11, 56, 57], raising the possibility that decreasing usage may positively impact patients’ day-to-day life. The long-term safety profile was favorable, including no significant intraoperative complications except for one case with slight hyphema that self-resolved without sequelae; postoperative adverse events that were few in number and mild in severity; and no serious ocular adverse events such as those seen with traditional filtering surgery or even some other MIGS devices [e.g., hypotony, endophthalmitis, corneal complications, myopic shift, stent obstruction, PAS, or choroidal detachment] [13–15, 58, 59]. Even though 3 years elapsed in this study, patients’ visual acuity remained stable, with 100% of eligible eyes retaining CDVA of 20/50 or better through 36 months postoperatively. Two eyes underwent additional glaucoma procedures at 1 month postoperatively due to the need for further IOP lowering, but no other secondary glaucoma surgeries occurred throughout follow-up. This latter observation is notable considering the sizable preoperative disease burden of this cohort, as many of the eyes likely would have undergone filtration surgery if stent implantation were not performed. Despite the study’s strengths, several limitations may be discussed. The study design was non-randomized, unmasked, and consisted of single-surgeon, single-site data. As in nearly all real-world case series, no medication washouts were completed pre- or postoperatively, since these could place patients at undue risk that would not be indicated in standard clinical practice. For similar reasons, there was no control group to act as a counterpoint to the stent-implantation group; however, it is reasonable to treat patients’ preoperative numeric data (such as IOP and number of medications) as viable comparators given the objective nature of these measures. This was a real-world, consecutive series, and thus no additional inclusion criteria were used outside of the surgeon’s typical prerequisites for undergoing stent surgery. Future reports from this data set could include longer periods of follow-up; stratified outcomes by preoperative medications or prior glaucoma surgery; refractive data; and longitudinal analysis of the C:D ratio, VF, and OCT-measured retinal nerve fiber layer thickness.

Conclusion

In summary, this real-world prospective cohort of glaucomatous eyes with considerable preoperative disease burden achieved significant and sustained IOP and medication reductions through 36 months after stand-alone iStent inject implantation. Favorable long-term safety accompanied these outcomes, yielding a promising benefit-to-risk ratio that supports the viability of this treatment modality in eyes with mild to advanced glaucoma. Since outcomes were observed in a real-world clinical setting, the data can be informative for practicing surgeons and patients making treatment decisions.
  57 in total

1.  Combined iStent trabecular micro-bypass stent implantation and phacoemulsification for coexistent open-angle glaucoma and cataract: a long-term study.

Authors:  Pedro Arriola-Villalobos; José Maria Martínez-de-la-Casa; David Díaz-Valle; Cristina Fernández-Pérez; Julián García-Sánchez; Julián García-Feijoó
Journal:  Br J Ophthalmol       Date:  2012-01-23       Impact factor: 4.638

2.  Manchester iStent study: 3-year results and cost analysis.

Authors:  S Z Tan; L Au
Journal:  Eye (Lond)       Date:  2016-07-08       Impact factor: 3.775

3.  Reduction in intraocular pressure after cataract extraction: the Ocular Hypertension Treatment Study.

Authors:  Steven L Mansberger; Mae O Gordon; Henry Jampel; Anjali Bhorade; James D Brandt; Brad Wilson; Michael A Kass
Journal:  Ophthalmology       Date:  2012-05-16       Impact factor: 12.079

4.  iStent inject in phakic open angle glaucoma.

Authors:  Matthias K J Klamann; Johannes Gonnermann; Milena Pahlitzsch; Anna-Karina B Maier; Antonia M Joussen; Necip Torun; Eckart Bertelmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-26       Impact factor: 3.117

5.  Prevalence of ocular surface disease in glaucoma patients.

Authors:  Eamon W Leung; Felipe A Medeiros; Robert N Weinreb
Journal:  J Glaucoma       Date:  2008-08       Impact factor: 2.503

6.  Trabecular micro-bypass stent implantation during small-incision cataract surgery for open-angle glaucoma or ocular hypertension: Long-term results.

Authors:  Tobias H Neuhann
Journal:  J Cataract Refract Surg       Date:  2015-12       Impact factor: 3.351

7.  The ocular surface of glaucoma patients treated over the long term expresses inflammatory markers related to both T-helper 1 and T-helper 2 pathways.

Authors:  Christophe Baudouin; Hong Liang; Pascale Hamard; Luisa Riancho; Catherine Creuzot-Garcher; Jean-Michel Warnet; Françoise Brignole-Baudouin
Journal:  Ophthalmology       Date:  2007-05-29       Impact factor: 12.079

8.  Prospective, unmasked evaluation of the iStent® inject system for open-angle glaucoma: synergy trial.

Authors:  Lilit Voskanyan; Julián García-Feijoó; Jose I Belda; Antonio Fea; Anselm Jünemann; Christophe Baudouin
Journal:  Adv Ther       Date:  2014-01-23       Impact factor: 3.845

9.  Outcomes Following Implantation of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication: 18-Month Follow-Up.

Authors:  Richard Lindstrom; Richard Lewis; Dana M Hornbeak; Lilit Voskanyan; Jane Ellen Giamporcaro; John Hovanesian; Steven Sarkisian
Journal:  Adv Ther       Date:  2016-10-13       Impact factor: 3.845

10.  Implantation of two second-generation trabecular micro-bypass stents and topical travoprost in open-angle glaucoma not controlled on two preoperative medications: 18-month follow-up.

Authors:  John Berdahl; Lilit Voskanyan; Jonathan S Myers; Dana M Hornbeak; Jane Ellen Giamporcaro; L Jay Katz; Thomas W Samuelson
Journal:  Clin Exp Ophthalmol       Date:  2017-06-02       Impact factor: 4.207

View more
  16 in total

1.  iStent for Adults With Glaucoma: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2021-07-21

2.  Two-Year Multicenter Outcomes of iStent inject Trabecular Micro-Bypass Stents Combined with Phacoemulsification in Various Types of Glaucoma and Ocular Hypertension.

Authors:  Colin Clement; Frank Howes; Alexandros S Ioannidis; Michael Shiu; David Manning; Jed Lusthaus; Ridia Lim; Simon E Skalicky; Todd Goodwin
Journal:  Clin Ophthalmol       Date:  2020-10-28

3.  Two-Year Comparative Outcomes of First- and Second-Generation Trabecular Micro-Bypass Stents with Cataract Surgery.

Authors:  Ricardo Augusto Paletta Guedes; Daniela Marcelo Gravina; Vanessa Maria Paletta Guedes; Alfredo Chaoubah
Journal:  Clin Ophthalmol       Date:  2021-05-05

4.  iStent inject trabecular microbypass stent implantation with cataract extraction in open-angle glaucoma: early clinical experience.

Authors:  Tanner J Ferguson; Zachary Dockter; Adam Bleeker; Kayla L Karpuk; Justin Schweitzer; Mitch J Ibach; John P Berdahl
Journal:  Eye Vis (Lond)       Date:  2020-05-20

Review 5.  Use of iStent as a Standalone Operation in Patients with Open-Angle Glaucoma.

Authors:  Yu-Yen Chen; Yun-Ju Lai; Yung-Feng Yen; Li-Ying Huang
Journal:  J Ophthalmol       Date:  2020-05-24       Impact factor: 1.909

6.  One-Year Comparative Evaluation of iStent or iStent inject Implantation Combined with Cataract Surgery in a Single Center.

Authors:  Ricardo Augusto Paletta Guedes; Daniela Marcelo Gravina; Jonathan Clive Lake; Vanessa Maria Paletta Guedes; Alfredo Chaoubah
Journal:  Adv Ther       Date:  2019-08-22       Impact factor: 3.845

7.  Second-generation trabecular micro-bypass stent implantation: Retrospective analysis after 12- and 24-month follow-up.

Authors:  Raphael Neuhann; Tobias Neuhann
Journal:  Eye Vis (Lond)       Date:  2020-01-10

8.  Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery.

Authors:  David Manning
Journal:  Ophthalmol Ther       Date:  2019-08-17

9.  Four-Year Outcomes of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication.

Authors:  Richard Lindstrom; Steven R Sarkisian; Richard Lewis; John Hovanesian; Lilit Voskanyan
Journal:  Clin Ophthalmol       Date:  2020-01-13

10.  The Efficacy and Safety of High-Frequency Deep Sclerotomy in Treatment of Chronic Open-Angle Glaucoma Patients.

Authors:  Mokhtar Mohamed Ibrahim Abushanab; Ayman El-Shiaty; Tarek El-Beltagi; Shaymaa Hassan Salah
Journal:  Biomed Res Int       Date:  2019-11-16       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.