| Literature DB >> 32566270 |
Yu-Yen Chen1,2,3,4, Yun-Ju Lai1,5,6, Yung-Feng Yen7,8,9, Li-Ying Huang10,11,12.
Abstract
PURPOSE: The iStent provides a direct pathway for aqueous outflow from the anterior chamber to Schlemm's canal in patients with open-angle glaucoma (OAG). We performed a meta-analysis to evaluate the effectiveness of iStent as a standalone operation in patients with OAG in reducing the intraocular pressure (IOP) and the number of topical glaucoma medications.Entities:
Year: 2020 PMID: 32566270 PMCID: PMC7267876 DOI: 10.1155/2020/8754730
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Figure 1Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) flow diagram for the searching and identification of included studies.
Characteristics of patients in studies included in meta-analysis.
| Author, year | Age (years) | iStent generation | iStent number | Follow-up (months) | Number of eyes | Baseline IOP (mmHg) | End point IOP (mmHg) | Number of baseline medications | Number of end point medications | Reduction in IOP (mmHg) | Reduction in number of medications |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Buznego, 2008 [ | NR | First | 1 | 18 | 41 | 21.5 ± 6.9 | 16.7 ± 6.9 | 1.6 ± 1.7 | 0.4 ± 1.7 | 4.8 | 1.2 |
| Ahmed et al., 2014 [ | 62.8 ± 12.6 | First | 2 | 18 | 39 | 22.2 ± 2.0 | 11.8 ± 2.1 | 2 ± 0 | 1 ± 0 | 10.4 | 1 ± 0 |
| Fea et al., 2014 [ | 64.5 ± 10.3 | Second | 2 | 12 | 94 | 21.1 ± 1.7 | 13.0 ± 2.3 | 1 ± 0 | 0.09 ± 0.40 | 8.1 ± 2.6 | 0.91 ± 0.40 |
| Voskanyan et al., 2014 [ | 66.4 ± 10.9 | Second | 2 | 12 | 99 | 22.1 ± 3.3 | 15.7 ± 3.7 | 2.21 ± 0.44 | NR | 6.4 | 1.78 ± 0.91 |
| Donnenfeld et al., 2015 [ | 66.7 ± 10.0 | First | 2 | 36 | 39 | 20.6 ± 2.0 | 15.2 ± 2.1 | 1 ± 0 | NR | 5.5 ± 2.7 | NR |
| Katz et al., 2015 [ | 68.1 ± 9.1 | First | 1 | 18 | 38 | 19.8 ± 1.3 | 15.6 ± 1.5 | 1.71 ± 0.61 | 0.111 ± 0.5 | 4.2 | 1.6 |
| 67.8 ± 9.3 | First | 2 | 18 | 41 | 20.1 ± 1.6 | 13.8 ± 1.3 | 1.76 ± 0.54 | 0.121 ± 0.394 | 6.3 | 1.64 | |
| 60.9 ± 8.1 | First | 3 | 18 | 40 | 20.4 ± 1.8 | 12.1 ± 1.2 | 1.51 ± 0.69 | 0.079 ± 0.269 | 8.3 | 1.50 | |
| Klamann et al., 2015 [ | 61.67 ± 5.15 | Second | 2 | 6 | 17 (POAG) | 21.19 ± 2.56 | 14.19 ± 1.38 | 2.19 ± 0.91 | 0.88 ± 0.62 | 7.0 | 1.31 |
| 62.76 ± 4.81 | Second | 2 | 6 | 15 (PEX) | 23.75 ± 3.28 | 15.33 ± 1.07 | 2.33 ± 1.23 | 1.04 ± 0.30 | 8.42 | 1.29 | |
| Ferguson et al., 2016 [ | 80.07 ± 8.54 | First | 1 | 24 | 42 | 20.26 ± 6.00 | 13.62 ± 4.55 | 1.95 ± 1.01 | 1.33 ± 1.22 | 6.64 | 0.62 |
| Lindstrom et al., 2016 [ | 65.3 ± 9.0 | Second | 2 | 18 | 57 | 19.5 ± 1.5 | 14.4 ± 2.1 | 1 ± 0 | 0.02 ± 0.13 | 5.1 | 0.98 |
| Vold et al., 2016 [ | 64.5 ± 11.1 | First | 2 | 36 | 54 | 25.5 ± 2.5 | 14.6 ± 2.4 | 0 ± 0 | 0.21 ± 0.54 | 10.9 | 0.79 |
| Berdahl et al., 2017 [ | 64.7 ± 9.6 | Second | 2 | 18 | 53 | 19.7 ± 1.5 | 12.9 ± 2.1 | 2 ± 0 | 1 ± 0 | 6.8 | 1 ± 0 |
| Chang et al., 2017 [ | 62.8 ± 12.6 | First | 2 | 36 | 39 | 22.4 ± 2.3 | 14.0 ± 2.6 | 2 ± 0 | 1 ± 0 | 8.4 | 1 ± 0 |
| Pahlitzsch et al., 2017 [ | 68.6 ± 16.4 | First | 2 | 6 | 20 | 21.3 | 16.0 | 2.45 | 2.5 | 5.3 | Increase 0.05 |
| Shiba et al., 2017 [ | 64.6 ± 10.7 | First | 2 | 6 | 10 | 22.0 ± 3.0 | 16.9 ± 3.6 | NR | NR | 5.1 | NR |
| Katz et al., 2018 [ | 68.1 ± 9.1 | First | 1 | 42 | 38 | 19.8 ± 1.3 | 15.0 ± 2.8 | 1.71 ± 0.61 | 0.55 ± 0.50 | 4.8 | 1.16 |
| 68.1 ± 9.1 | First | 2 | 42 | 41 | 20.1 ± 1.6 | 15.7 ± 1.0 | 1.76 ± 0.54 | 0.105 ± 0.307 | 4.4 | 1.66 | |
| 68.1 ± 9.1 | First | 3 | 42 | 40 | 20.4 ± 1.8 | 14.8 ± 1.3 | 1.53 ± 0.69 | 0.08 ± 0.27 | 5.6 | 1.45 | |
| Ahmed et al., 2019 [ | 66.5 ± 9.5 | First | 2 | 12 | 77 | 19.1 ± 3.6 | 18.1 ± 3.7 | 2.7 ± 0.8 | 1.69 ± 1.37 | 1.0 | 1.01 |
| Hengerer et al., 2019 [ | 71.3 ± 10.5 | Second | 2 | 36 | 44 | 25.3 ± 6.0 | 14.6 ± 2.0 | 2.98 ± 0.88 | 0.55 ± 0.79 | 10.7 | 2.43 |
PEX = pseudoexfoliation glaucoma.
Figure 2The overall effect of iStent on intraocular pressure.
Figure 3The overall effect of iStent on the number of glaucoma medications.
Figure 4Funnel plot of studies regarding iStent on IOP. IOP: intraocular pressure.
Figure 5Funnel plot of studies regarding iStent on the number of medications.
Success rate and complications of studies included in meta-analysis.
| Author, year | Number of eyes at baseline | Number of eyes at end point | Success rate | Complication rate | ||
|---|---|---|---|---|---|---|
| IOP ≤18 mmHg ( | IOP reduction ≥20% ( | Event ( | Types of complication (%) | |||
| Buznego, 2008 [ | 41 | 41 | 41 (100) | NR | 6 (15) | Malposition (15) |
| Ahmed et al., 2014 [ | 39 | 39 | 39 (100) | 39 (100) | 0 (0) | None |
| Fea et al., 2014 [ | 94 | 94 | 87 (92.6) | 89 (94.7) | 3 (3) | IOP decompensation (1), one stent not visible (1), soreness/discomfort (1) |
| Voskanyan et al., 2014 [ | 99 | 88 | 71 (80.7) | 82 (93.2) | 35 (35.3) | Elevated IOP (10.1), iStent obstruction (3), progression of cataract (1), allergic reaction to medications (1), iStent malposition (1), intraocular inflammation (1), subconjunctival hemorrhage (1), iStent not visible upon gonioscopy (13.1), posterior capsular opacification (2), goniosynechiae (1), lens-iris synechiae (1) |
| Donnenfeld et al., 2015 [ | 39 | 29 | 26 (89.7) | 25 (86.2) | 10 (25.6) | Progression of cataract (7.7), death (5.1), hyphema (2.6), initial cataract (2.6), proliferative diabetic retinopathy (2.6), scar from age-related macular degeneration (2.6), cataract surgery (2.6) |
| Katz et al., 2015 [ | 38 (1 device) | 37 | 33 (89.2) | 33 (89.2) | 2 (5.3) | Cataract surgery (5.3) |
| 41 (2 devices) | 41 | 37 (90.2) | 37 (90.2) | 0 (0) | None | |
| 40 (3 devices) | 38 | 35 (92.1) | 35 (92.1) | 2 (5.3) | Cataract surgery (5.3) | |
| Klamann et al., 2015 [ | 17 (POAG) | 17 | NR | NR | 32 (91.4) | Intraoperative blood reflux (91.4) |
| 15 (PEX) | 15 | NR | NR | |||
| 3 (PG) | 3 | NR | NR | |||
| Ferguson et al., 2016 [ | 42 | 42 | NR | NR | 1 (2.4) | Elevated IOP (2.4) |
| Lindstrom et al., 2016 [ | 57 | 57 | 57 (100) | 43 (75.4) | 1 (1.8) | Progression of cataract (1.8) |
| Vold et al., 2016 [ | 54 | 34 | 31 (91.1) | NR | 12 (22.2) | Progression of cataract (20.4), hyphema (1.8) |
| Berdahl et al., 2017 [ | 53 | 53 | 46 (86.8) | 48 (90.6) | 0 (0) | None |
| Chang et al., 2017 [ | 39 | 35 | 30 (85.7) | 34 (97.1) | 13 (33.3) | Transient hypotony (5.1), progression of cataract (23.1), insomnia/malaise (2.6), herpetic corneal ulcer (2.6) |
| Pahlitzsch et al., 2017 [ | 20 | 20 | NR | NR | NR | NR |
| Shiba et al., 2017 [ | 10 | 8 | 4 (50) | 4 (50) | 9 (90) | Hyphema (40), elevated IOP (10), peripheral anterior synechiae (40) |
| Katz et al., 2018 [ | 38 (1 device) | 28 | NR | 17 (60.7) | 8 (21.1) | Progression of cataract (21.1) |
| 41 (2 devices) | 35 | NR | 32 (91.4) | 5 (12.2) | Progression of cataract (12.2) | |
| 40 (3 devices) | 35 | NR | 32 (91.4) | 7 (17.5) | Progression of cataract (17.5) | |
| Ahmed et al., 2019 [ | 77 | 75 | 43 (57.3) | 10 (13.3) | 15 (19.5) | Elevated IOP (5.2), new cataract (1.3), iStent obstruction (13.0) |
| Hengerer et al., 2019 [ | 44 | 33 | 32 (97.0) | 29 (87.9) | 4 (9.1) | Mild hyphema (2.3), progression of cataract (4.5), uveitis (2.3) |
Figure 6Proportion of eyes with an IOP ≤18 mmHg at the end point.
Figure 7Proportion of eyes with an IOP reduction ≥20% at the end point.
Figure 8Subgroup analysis regarding the effect of iStent on intraocular pressure, stratified by (a) iStent generation, (b) follow-up time, and (c) iStent numbers.
Figure 9Subgroup analysis regarding the effect of iStent on the number of medications, stratified by (a) iStent generation, (b) follow-up time, and (c) iStent numbers.