Literature DB >> 22275344

Combined iStent trabecular micro-bypass stent implantation and phacoemulsification for coexistent open-angle glaucoma and cataract: a long-term study.

Pedro Arriola-Villalobos1, José Maria Martínez-de-la-Casa, David Díaz-Valle, Cristina Fernández-Pérez, Julián García-Sánchez, Julián García-Feijoó.   

Abstract

AIMS: To evaluate the long-term efficacy and safety of combined cataract surgery and Glaukos iStent implantation for coexistent open-angle glaucoma and cataract.
METHODS: Prospective, non-comparative, uncontrolled, non-randomised, interventional case series study. Subjects older than 18 years with coexistent uncontrolled mild or moderate open-angle glaucoma (including pseudoexfoliative and pigmentary) and cataract underwent phacoemulsification and intraocular lens implantation along with ab-interno gonioscopically guided implantation of one Glaukos iStent. The variables recorded during a minimum of 3 years of follow-up were: intraocular pressure (IOP), number of antiglaucoma medications and best-corrected visual acuity.
RESULTS: The 19 patients enrolled were 58-88 years old (mean age 74.6±8.44 years). Mean follow-up was 53.68±9.26 months. Mean IOP was reduced from 19.42±1.89 mm Hg to 16.26±4.23 mm Hg (p=0.002) at the end of follow up, indicating a 16.33% decrease in IOP. The mean number of pressure-lowering medications used by the patients fell from 1.32±0.48 to 0.84±0.89 (p=0.046). In 42% of patients, no antiglaucoma medications were used at the end of follow-up. Mean best-corrected visual acuity significantly improved from 0.29±0.13 to 0.62±0.3 (p<0.001). No complications of surgery were observed.
CONCLUSION: Combined cataract surgery and Glaukos iStent implantation seems to be an effective and safe procedure to treat coexistent open-angle glaucoma and cataract.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22275344     DOI: 10.1136/bjophthalmol-2011-300218

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  66 in total

1.  Manchester iStent study: 3-year results and cost analysis.

Authors:  S Z Tan; L Au
Journal:  Eye (Lond)       Date:  2016-07-08       Impact factor: 3.775

2.  Implantation of trabecular micro-bypass stent using a novel "landing strip" technique.

Authors:  Cindy X Zheng; Marlene R Moster; Priyanka Gogte; Yang Dai; Remy S Manzi; Michael Waisbourd
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

3.  [Minimally invasive iridocorneal angle surgery].

Authors:  J F Jordan
Journal:  Ophthalmologe       Date:  2012-07       Impact factor: 1.059

Review 4.  Techniques and outcomes of minimally invasive trabecular ablation and bypass surgery.

Authors:  Kevin Kaplowitz; Joel S Schuman; Nils A Loewen
Journal:  Br J Ophthalmol       Date:  2013-12-12       Impact factor: 4.638

Review 5.  [Trabecular micro-invasive glaucoma surgery : Procedures and clinical results].

Authors:  A G M Jünemann; R Rejdak; B Hohberger
Journal:  Ophthalmologe       Date:  2018-05       Impact factor: 1.059

6.  The XEN45 Gel Stent as a minimally invasive procedure in glaucoma surgery: success rates, risk profile, and rates of re-surgery after 261 surgeries.

Authors:  Randolf A Widder; Thomas S Dietlein; Sven Dinslage; Pia Kühnrich; Corinna Rennings; Gernot Rössler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-01-22       Impact factor: 3.117

7.  One-year result of XEN45 implant for glaucoma: efficacy, safety, and postoperative management.

Authors:  S Z Tan; A Walkden; L Au
Journal:  Eye (Lond)       Date:  2017-09-01       Impact factor: 3.775

8.  There has to be a better way: evolution of internal filtration glaucoma surgeries.

Authors:  Nils A Loewen; Joel S Schuman
Journal:  Br J Ophthalmol       Date:  2013-10       Impact factor: 4.638

9.  One Year of Glaucoma Research in Review: 2012 to 2013.

Authors:  Charles Kim; Anna M Demetriades; Nathan M Radcliffe
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2014 Jan-Feb

Review 10.  Aqueous outflow: segmental and distal flow.

Authors:  Swarup S Swaminathan; Dong-Jin Oh; Min Hyung Kang; Douglas J Rhee
Journal:  J Cataract Refract Surg       Date:  2014-08       Impact factor: 3.351

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.