Literature DB >> 31104563

Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position.

Tomoyuki Kamenaga1, Shinya Hayashi1, Shingo Hashimoto1, Tomoyuki Matsumoto1, Koji Takayama1, Takaaki Fujishiro2, Takafumi Hiranaka2, Takahiro Niikura1, Ryosuke Kuroda1.   

Abstract

PURPOSE: To assess the accuracy of cup orientation and learning curve of the disposable accelerometer-based portable navigation system for total hip arthroplasty (THA) in the supine position.
METHODS: A total of 75 patients who underwent THA through the anterolateral supine approach (ALS) with an accelerometer-based portable navigation system for the supine position (HipAlign®) between July 2017 and October 2018 were analyzed in this study. We compared the intraoperative cup angles using navigation records with the postoperative angles using postoperative computed tomography (CT) data. All patients were categorized into the following groups according to the course of three discrete, sequential operative time periods: 1-25 (initial group), 26-50 (intermediate group), and 51-75 (recent group). We compared the accuracy of cup inclination and anteversion among the three groups. The time required for navigation and the operative time of all patients were measured.
RESULTS: The average absolute error in measurement (postoperative CT-navigation record) was 2.6° ± 2.7° (inclination) and 2.8° ± 2.7° (anteversion). There were no significant differences among the three groups. The average time required for navigation and the operative time were 365.1 ± 90.3 s and 76.1 ± 1.6 min, respectively. The required time for HipAlign® navigation and operative time were constant in most patients, except for those of the initial five cases.
CONCLUSION: The accelerometer-based portable navigation system provides good accuracy of cup orientation, has a short learning curve, and requires a minimal surgical time for THA in supine position.

Entities:  

Keywords:  cup orientation; learning curve; navigation; total hip arthroplasty

Mesh:

Year:  2019        PMID: 31104563     DOI: 10.1177/2309499019848871

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  6 in total

1.  Portable imageless navigation system and surgeon's estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position.

Authors:  Ryohei Takada; Tetsuya Jinno; Kazumasa Miyatake; Masanobu Hirao; Toshitaka Yoshii; Atsushi Okawa
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-10

2.  Improving Acetabular Component Positioning in Total Hip Arthroplasty: A Cadaveric Study of an Inertial Navigation Tool and a Novel Registration Method.

Authors:  Jobe Shatrov; Daniel Marsden-Jones; Matt Lyons; William L Walter
Journal:  HSS J       Date:  2021-11-02

3.  Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position.

Authors:  Masahiro Hasegawa; Yohei Naito; Shine Tone; Akihiro Sudo
Journal:  BMC Musculoskelet Disord       Date:  2022-06-04       Impact factor: 2.562

4.  Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study.

Authors:  Hiromasa Tanino; Yasuhiro Nishida; Ryo Mitsutake; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2021-03-23       Impact factor: 2.362

5.  Pelvic Tilt Reduces the Accuracy of Acetabular Component Placement When Using a Portable Navigation System: An In Vitro Study.

Authors:  Hiroshi Asai; Yasuhiko Takegami; Taisuke Seki; Naoki Ishiguro
Journal:  Arthroplast Today       Date:  2021-02-01

6.  Validity of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty: protocol for a prospective observational cohort study in a single-surgeon practice.

Authors:  Nalan Ektas; Corey Scholes; Alejandro M Ruiz; John Ireland
Journal:  BMJ Open       Date:  2020-10-05       Impact factor: 2.692

  6 in total