Literature DB >> 31925538

Portable imageless navigation system and surgeon's estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position.

Ryohei Takada1, Tetsuya Jinno2, Kazumasa Miyatake2, Masanobu Hirao2, Toshitaka Yoshii2, Atsushi Okawa2.   

Abstract

BACKGROUND: This prospective study aimed to clarify whether this novel device can evaluate the cup orientation during total hip arthroplasty (THA) more closely to that measured in postoperative computed tomography (CT) compared to the surgeon's estimate using a manual goniometer.
METHODS: We prospectively performed 30 cementless THAs via the anterolateral approach in supine position between October 2018 and July 2019, wherein cup orientation was evaluated by both a portable imageless navigation system (HipAlign) and a manual goniometer during surgeries. Primary outcome was the absolute estimate error [the absolute value of the difference between cup angles measured by postoperative CT and those measured by HipAlign (group H) or surgeon's estimate using the manual goniometer (group S) during surgery]. The number of outliers of the absolute estimate error (> 10°) in each group was also estimated.
RESULTS: The absolute estimate error of cup inclination in groups H and S was 3.3° ± 2.7° and 3.0° ± 2.5°, respectively (p = 0.51), whereas that of cup anteversion was 3.8° ± 3.4° and 6.0° ± 3.7°, respectively (p = 0.0008). The number of outliers of the estimate error in groups H and S was one case (3.3%) and six cases (20.0%), respectively (p = 0.04). In all six outlier cases, surgeons underestimated cup anteversion during surgeries.
CONCLUSIONS: This portable imageless navigation system was a useful method, especially for avoiding incorrect cup anteversion. Underestimation of cup anteversion during THA in the supine position with the conventional alignment assisting device should be given attention.

Entities:  

Keywords:  Acetabular cup orientation; Portable imageless navigation system; Range of motion; Total hip arthroplasty

Mesh:

Year:  2020        PMID: 31925538     DOI: 10.1007/s00590-020-02625-2

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  22 in total

1.  Compliant positioning of total hip components for optimal range of motion.

Authors:  K-H Widmer; B Zurfluh
Journal:  J Orthop Res       Date:  2004-07       Impact factor: 3.494

2.  Accelerometer-based, portable navigation vs imageless, large-console computer-assisted navigation in total knee arthroplasty: a comparison of radiographic results.

Authors:  Denis Nam; K Durham Weeks; Keith R Reinhardt; Danyal H Nawabi; Michael B Cross; David J Mayman
Journal:  J Arthroplasty       Date:  2012-06-14       Impact factor: 4.757

Review 3.  Impingement with total hip replacement.

Authors:  Aamer Malik; Aditya Maheshwari; Lawrence D Dorr
Journal:  J Bone Joint Surg Am       Date:  2007-08       Impact factor: 5.284

4.  Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation.

Authors:  N Sugano; T Nishii; H Miki; H Yoshikawa; Y Sato; S Tamura
Journal:  J Bone Joint Surg Br       Date:  2007-04

5.  Total hip arthroplasty using imageless computer-assisted hip navigation: a prospective randomized study.

Authors:  Richard Lass; Bernd Kubista; Boris Olischar; Sophie Frantal; Reinhard Windhager; Alexander Giurea
Journal:  J Arthroplasty       Date:  2013-11-26       Impact factor: 4.757

6.  EOS-based cup navigation: Randomised controlled trial in 78 total hip arthroplasties.

Authors:  N Verdier; A Billaud; T Masquefa; J Pallaro; T Fabre; C Tournier
Journal:  Orthop Traumatol Surg Res       Date:  2016-04-01       Impact factor: 2.256

7.  Can a target zone safer than Lewinnek's safe zone be defined to prevent instability of total hip arthroplasties? Case-control study of 56 dislocated THA and 93 matched controls.

Authors:  N Reina; S Putman; R Desmarchelier; E Sari Ali; P Chiron; M Ollivier; J Y Jenny; D Waast; C Mabit; E de Thomasson; C Schwartz; P Oger; L E Gayet; H Migaud; N Ramdane; M H Fessy
Journal:  Orthop Traumatol Surg Res       Date:  2017-06-16       Impact factor: 2.256

8.  Supine versus lateral position for accurate positioning of acetabular cup in total hip arthroplasty using the modified Watson-Jones approach: A randomized single-blind controlled trial.

Authors:  Ryohei Takada; Tetsuya Jinno; Kazumasa Miyatake; Masanobu Hirao; Kazuyoshi Yagishita; Toshitaka Yoshii; Atsushi Okawa
Journal:  Orthop Traumatol Surg Res       Date:  2019-06-14       Impact factor: 2.256

9.  A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

Authors:  Hiroyuki Ogawa; Seiichirou Hasegawa; Sachiyuki Tsukada; Masaaki Matsubara
Journal:  J Arthroplasty       Date:  2018-02-05       Impact factor: 4.757

10.  A clinical comparative study of the direct anterior with mini-posterior approach: two consecutive series.

Authors:  Katsuya Nakata; Masataka Nishikawa; Koji Yamamoto; Shigeaki Hirota; Hideki Yoshikawa
Journal:  J Arthroplasty       Date:  2008-06-13       Impact factor: 4.757

View more
  3 in total

1.  Improving Acetabular Component Positioning in Total Hip Arthroplasty: A Cadaveric Study of an Inertial Navigation Tool and a Novel Registration Method.

Authors:  Jobe Shatrov; Daniel Marsden-Jones; Matt Lyons; William L Walter
Journal:  HSS J       Date:  2021-11-02

2.  Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position.

Authors:  Masahiro Hasegawa; Yohei Naito; Shine Tone; Akihiro Sudo
Journal:  BMC Musculoskelet Disord       Date:  2022-06-04       Impact factor: 2.562

3.  Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study.

Authors:  Hiromasa Tanino; Yasuhiro Nishida; Ryo Mitsutake; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2021-03-23       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.