Literature DB >> 31086717

Balloon catheter-based radiofrequency ablation monitoring in porcine esophagus using optical coherence tomography.

William C Y Lo1,2,3, Néstor Uribe-Patarroyo1,4, Katharina Hoebel1, Kathy Beaudette1, Martin Villiger1, Norman S Nishioka1,5, Benjamin J Vakoc1,2, Brett E Bouma1,2.   

Abstract

We present a microscopic image guidance platform for radiofrequency ablation (RFA) using a clinical balloon-catheter-based optical coherence tomography (OCT) system, currently used in the surveillance of Barrett's esophagus patients. Our integrated thermal therapy delivery and monitoring platform consists of a flexible, customized bipolar RFA electrode array designed for use with a clinical balloon OCT catheter and a processing algorithm to accurately map the thermal coagulation process. Non-uniform rotation distortion was corrected using a feature tracking-based technique, which enables robust, frame-to-frame analysis of the temporal fluctuation of the complex OCT signal. With proper noise calibration, precise delineation of the thermal therapy zone was demonstrated using cumulative complex differential variance in porcine esophagus ex vivo with the integrated OCT-RFA system, as validated by nitroblue tetrazolium chloride (NBTC) histology. The ability to directly and accurately visualize the thermal coagulation process at high resolution is critical to the precise delivery of thermal energy to a wide range of epithelial lesions.

Entities:  

Year:  2019        PMID: 31086717      PMCID: PMC6484999          DOI: 10.1364/BOE.10.002067

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  51 in total

1.  Comprehensive esophageal microscopy by using optical frequency-domain imaging (with video).

Authors:  Benjamin J Vakoc; Milen Shishko; Seok H Yun; Wang-Yuhl Oh; Melissa J Suter; Adrien E Desjardins; John A Evans; Norman S Nishioka; Guillermo J Tearney; Brett E Bouma
Journal:  Gastrointest Endosc       Date:  2007-03-26       Impact factor: 9.427

2.  Balloon-based, circumferential, endoscopic radiofrequency ablation of Barrett's esophagus: 1-year follow-up of 100 patients.

Authors:  Virender K Sharma; Kenneth K Wang; Bergein F Overholt; Charles J Lightdale; M Brian Fennerty; Patrick J Dean; Douglas K Pleskow; Ram Chuttani; Alvaro Reymunde; Nilda Santiago; Kenneth J Chang; Michael B Kimmey; David E Fleischer
Journal:  Gastrointest Endosc       Date:  2007-02       Impact factor: 9.427

3.  Updated guidelines 2008 for the diagnosis, surveillance and therapy of Barrett's esophagus.

Authors:  Kenneth K Wang; Richard E Sampliner
Journal:  Am J Gastroenterol       Date:  2008-03       Impact factor: 10.864

4.  Real-time microscopic visualization of tissue response to laser thermal therapy.

Authors:  Benjamin J Vakoc; Guillermo J Tearney; Brett E Bouma
Journal:  J Biomed Opt       Date:  2007 Mar-Apr       Impact factor: 3.170

5.  Enzyme histochemical analysis of cell viability after argon laser-induced coagulation necrosis of the skin.

Authors:  R A Neumann; R M Knobler; F Pieczkowski; W Gebhart
Journal:  J Am Acad Dermatol       Date:  1991-12       Impact factor: 11.527

6.  Analysis of tissue and arterial blood temperatures in the resting human forearm.

Authors:  H H PENNES
Journal:  J Appl Physiol       Date:  1948-08       Impact factor: 3.531

Review 7.  Ratio of entropy to enthalpy in thermal transitions in biological tissues.

Authors:  Steven L Jacques
Journal:  J Biomed Opt       Date:  2006 Jul-Aug       Impact factor: 3.170

8.  Complete ablation of esophageal epithelium with a balloon-based bipolar electrode: a phased evaluation in the porcine and in the human esophagus.

Authors:  Robert A Ganz; David S Utley; Roger A Stern; Jerome Jackson; Kenneth P Batts; Paul Termin
Journal:  Gastrointest Endosc       Date:  2004-12       Impact factor: 9.427

9.  Thin-layer ablation of human esophageal epithelium using a bipolar radiofrequency balloon device.

Authors:  B J Dunkin; J Martinez; P A Bejarano; C D Smith; K Chang; A S Livingstone; W S Melvin
Journal:  Surg Endosc       Date:  2005-12-07       Impact factor: 3.453

Review 10.  Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future.

Authors:  Enrique J Berjano
Journal:  Biomed Eng Online       Date:  2006-04-18       Impact factor: 2.819

View more
  3 in total

1.  Noise and bias in optical coherence tomography intensity signal decorrelation.

Authors:  Néstor Uribe-Patarroyo; Anouk L Post; Sebastián Ruiz-Lopera; Dirk J Faber; Brett E Bouma
Journal:  OSA Contin       Date:  2020-03-17

2.  Steerable OCT catheter for real-time assistance during teleoperated endoscopic treatment of colorectal cancer.

Authors:  Oscar Caravaca Mora; Philippe Zanne; Lucile Zorn; Florent Nageotte; Natalia Zulina; Sara Gravelyn; Paul Montgomery; Michel de Mathelin; Bernard Dallemagne; Michalina J Gora
Journal:  Biomed Opt Express       Date:  2020-02-03       Impact factor: 3.732

Review 3.  Double-Clad Fiber-Based Multifunctional Biosensors and Multimodal Bioimaging Systems: Technology and Applications.

Authors:  Kathy Beaudette; Jiawen Li; Joseph Lamarre; Lucas Majeau; Caroline Boudoux
Journal:  Biosensors (Basel)       Date:  2022-02-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.