| Literature DB >> 31060548 |
Anis Hasnaoui1, Haithem Zaafouri2, Dhafer Haddad2, Ahmed Bouhafa2, Anis Ben Maamer2.
Abstract
BACKGROUND: Training programs such as the fundamentals of laparoscopic surgery (FLS) that are based on simulation are being currently used in several western countries. FLS allows skill acquisition and evaluation of competency in laparoscopic surgery. On the practical side, evaluation is determined by the MISTELS metrics (MISTELS is the acronym for the McGill inanimate system for training and evaluation of laparoscopic skills). This training program may be modified so that it can be implemented in countries with limited resources using a low-cost trainer box. Would the use of a low-cost trainer box alter the reliability of the MISTELS score? OBJECTIVE OF STUDY: The aim of the study was to evaluate the reliability of a modified MISTELS using a low-cost trainer box.Entities:
Keywords: Evaluation; FLS; Low-cost; MISTELS; Reliability; Simulation; Trainer box; Training
Mesh:
Year: 2019 PMID: 31060548 PMCID: PMC6503379 DOI: 10.1186/s12909-019-1572-4
Source DB: PubMed Journal: BMC Med Educ ISSN: 1472-6920 Impact factor: 2.463
Fig. 1Measurements in cm of the plates and folding lines
Fig. 2Images shown in real time onto the screen of the computer and the wall screen
Fig. 3Materials used during the performance of the MISTELS tasks
Correlation between the score of each task and the total score and impact of deletion of each task on Cronbach’s alpha and thus on internal consistency (Scores obtained in the series of retest)
| Tasks | Correlation with the total score | Cronbach’s alpha in case of deletion of the exercise |
|---|---|---|
| Peg transfer | 0.972 | 0.832 |
| Precision cutting | 0.894 | 0.951 |
| intra-corporeal knot | 0.952 | 0.889 |
Internal consistency assessed by Cronbach’s alpha and inter-rater reliability assessed by ICC of the modified MISTELS score
| Tasks | Rater 1 | Rater 2 | ICCb | ||
|---|---|---|---|---|---|
| Mean | SDa | Mean | SD | ||
| Peg transfer | 32.49 | 30.22 | 32.38 | 30.12 | 1 |
| Precision cutting | 20.80 | 24.61 | 20.63 | 24.62 | 1 |
| intra-corporeal knot | 27.42 | 29.58 | 27.5 | 29.70 | 1 |
| Total score | 80.72 | 81.14 | 80.52 | 81.02 | 1 |
| Cronbach’s alpha | 0.955 | 0.953 | |||
aSD Standard deviation, bICC Intraclass correlation coefficient
Fig. 4Modified MISTELS scores given to residents by two raters
Internal consistency assessed by Cronbach’s alpha and test-retest reliability assessed by ICC of the modified MISTELS score
| Tasks | Test | Retest | ICCb | ||
|---|---|---|---|---|---|
| Mean | SDa | Mean | SD | ||
| Peg transfer | 33.55 | 28.72 | 36.26 | 29.23 | 0.952 |
| Precision cutting | 26.69 | 24.09 | 32.96 | 23.07 | 0.769 |
| intra-corporeal knot | 31.45 | 32.47 | 28.96 | 31.17 | 0.902 |
| Total score | 91.69 | 80.65 | 98.18 | 78.70 | 0.950 |
| Cronbach’s alpha | 0.933 | 0.929 | |||
aSD Standard deviation, bICC Intraclass correlation coefficient
Fig. 5Modified MISTELS scores given to residents in the test and the retest series by a single rater