Ulvi Cenk Oezpeker1, Gudrun Feuchtner2, Nikolaos Bonaros1. 1. University Clinic of Cardiac Surgery, Medical University of Innsbruck, Anichstrasse 35, Innsbruck, Austria. 2. University Clinic of Radiology, Medical University of Innsbruck, Anichstrasse 35, Innsbruck, Austria.
Abstract
BACKGROUND: Surgical implantation rates of bioprosthetic valves, especially the use of sutureless or rapid deployment valves, as well as the advent of transcatheter valve implantation (TAVR) have increased during the last decades mainly due to their excellent haemodynamic and clinical results. One common characteristic of all bioprosthetic types of surgical aortic valve replacement (SAVR) and TAVR is the risk of early degeneration, which leads to valve-dysfunction and is associated with higher rates of valve reinterventions. Recent studies have demonstrated that cusp thrombosis may play a role in early valve dysfunction. This case report is, to our knowledge, the first documentation on a successful treatment of early aortic valve (AV) degeneration of a sutureless AV thrombosis with a valve-in-valve (ViV) TAVR implantation. CASE SUMMARY: A 77 years old woman was re-evaluated from the heart-team, which considered the following characteristics: severe impairment of mobility and frailty with an STS-score of 10.01% and a EuroSCORE II of 6.9%. Due to the high surgical risk for SAVR, we decided to perform a ViV-TAVR using a balloonexpandable bioprosthesis. The procedure was performed via transfemoral access under general anaesthesia using a 23 mm Edwards-Sapien 3 bioprosthesis without balloon-valvuloplasty and with nominal-volume dilation under rapid-pacing. DISCUSSION: The differentiation of bioprosthesis valve thrombosis, and hypoattenuating leaflet thickening vs. structural valve degeneration can be difficult, and a multimodality imaging approach, comprising trans-thoracic echocardiogram, transoesophageal echocardiography and computed tomography, useful. These investigations are very important to decide the right strategy of surgical valve replacement vs. TAVR.
BACKGROUND: Surgical implantation rates of bioprosthetic valves, especially the use of sutureless or rapid deployment valves, as well as the advent of transcatheter valve implantation (TAVR) have increased during the last decades mainly due to their excellent haemodynamic and clinical results. One common characteristic of all bioprosthetic types of surgical aortic valve replacement (SAVR) and TAVR is the risk of early degeneration, which leads to valve-dysfunction and is associated with higher rates of valve reinterventions. Recent studies have demonstrated that cusp thrombosis may play a role in early valve dysfunction. This case report is, to our knowledge, the first documentation on a successful treatment of early aortic valve (AV) degeneration of a sutureless AV thrombosis with a valve-in-valve (ViV) TAVR implantation. CASE SUMMARY: A 77 years old woman was re-evaluated from the heart-team, which considered the following characteristics: severe impairment of mobility and frailty with an STS-score of 10.01% and a EuroSCORE II of 6.9%. Due to the high surgical risk for SAVR, we decided to perform a ViV-TAVR using a balloonexpandable bioprosthesis. The procedure was performed via transfemoral access under general anaesthesia using a 23 mm Edwards-Sapien 3 bioprosthesis without balloon-valvuloplasty and with nominal-volume dilation under rapid-pacing. DISCUSSION: The differentiation of bioprosthesis valve thrombosis, and hypoattenuating leaflet thickening vs. structural valve degeneration can be difficult, and a multimodality imaging approach, comprising trans-thoracic echocardiogram, transoesophageal echocardiography and computed tomography, useful. These investigations are very important to decide the right strategy of surgical valve replacement vs. TAVR.
Entities:
Keywords:
Bioprosthesis thrombosis; Case report; Sutureless valve; Valve in valve TAVI
Learning pointsCusp thrombosis of a bioprosthesis may also affect sutureless valves and is probably related to an elliptic expansion of the prosthesis.Transcatheter valve-in-valve implantation can be used as a therapeutic option in case of failure of anticoagulation treatment.A combination of haemodynamic measurements and multimodality imaging is essential for the diagnosis of bioprosthetic cusp thrombosis and the evaluation of treatment success.
Introduction
Surgical implantation rates for bioprosthetic valves, especially sutureless or rapid deployment valves, as well as the advent of transcatheter valve implantation (TAVI) have increased during the last decades mainly due to their excellent haemodynamic and clinical results. One common characteristic of all bioprosthetic types of surgical aortic valve replacement (SAVR) and TAVI is the risk of early degeneration, which leads to valve dysfunction and is associated with higher reintervention rates. Recent studies have demonstrated that bioprosthetic valve thrombosis (BVT) may play a role in early valve dysfunction. This case report is, to our knowledge, the first documented report on therapy of a BVT of a sutureless valve (SV) with a valve-in-valve (ViV) TAVI.
Patient information
A 77-year-old woman presented at our department for treatment of a highly symptomatic low-flow (SVI: 23 mL/m2/1.73 m2 body surface area), low-gradient (mean: 38 mmHg) AV stenosis (AV area 0.52 cm2) with preserved ejection fraction (left-ventricular ejection fraction (LVEF): 58%), and a very hypertrophic left ventricular myocardium. In addition, she suffered from secondary pulmonary hypertension (catheter-measured systolic pulmonary artery pressure 50 mmHg). At that time she was dyspnoeic at New York Heart Association (NYHA) functional status III. Additional comorbidities included arterial hypertension, insulin-dependent diabetes mellitus, permanent pacemaker implantation due to sick-sinus syndrome and reported weight loss of 8 kg since the onset of symptoms.Due to moderate frailty with a 3.8% STS score and a 1.3% EuroSCORE II she was assigned for minimally invasive SAVR and received a self-expandable SV [PERCEVAL-S®, sizeM, (Livanova, Saluggia, Italy)]. Both the intra- and post-operative course were uneventful. The initial anticoagulation protocol was maintained with low-molecular weight heparin s.c. at a doses of 2× bodyweight in milligram with anti-Xa monitoring and addition of aspirin 100 mg/d, followed by acenocoumarol (INR target 2.0–3.0). Discharge echocardiography showed a mean pressure gradient (MPG) across the AV of 7 mmHg without AV regurgitation. She was readmitted 10 months after the index procedure with symptoms of recurrent heart failure, dyspnoea, pulmonary congestion (oxygen saturation 94%), peripheral oedema, mild end-diastolic murmur, paced heart rate 78 b.p.m., NYHA IV, and increased NT-proBNP.
Diagnostic assessment
Transthoracic echocardiography demonstrated recurrent AV stenosis (AV area 0.92 cm2), with a MPG of 12 mmHg with severe regurgitation and a preserved LV-EF (Figure ). Transoesophageal echocardiography (TOE) showed an immobile right-coronary cusp (RCC) due to BVT (Figure ). Cardiac computed tomography (CT) scan revealed a 12 × 4.9 mm thrombus at the ventricular aspect of the RCC and the right non-coronary commissure (Figure ) with an elliptic expansion shape (22.6 × 18.8 mm) of the bioprosthesis at the annulus level (Figure ). Any relevant coronary stenosis (>50%) was excluded by angiography prior to SAVR and coronary CT scan prior to ViV-TAVI.(A and B) Transoesophageal echocardiography with aortic valve gradient and thrombus pre-valve-in-valve transcatheter valve implantation.Aortic valve thrombus of PERCEVAL-S® seen by computed tomography scan.(A and B) Computed tomography scan pre- (elliptical shape A) and post-valve-in-valve transcatheter valve implantation (circular shape B).Acquired hypercoagulable disorders or systemic lupus erythematodes were excluded. Neoplastic diseases with paraneoplastic syndrome were excluded in the CT scan, and the patient’s initial gastrointestinal symptoms were thoroughly investigated with gastroscopy, colonoscopy, and intrauterine ultrasound.
Interventions
Pharmacological therapy for thrombus resolution was initiated with systemic heparinization (aPTT 50–60 s) followed by acenocoumarol (target INR: 2.5–3.5) for 3 months, according to the current guidelines/recommendations., Because of further clinical deterioration and failure of thrombus resolution, the patient was considered for redo-SAVR or ViV-TAVI. She was re-evaluated by the heart-team, which considered the following characteristics: severe frailty with a 10.01% STS score and a 6.9% EuroSCORE II. Due to this high surgical risk, we performed a transfemoral ViV-TAVI under general anaesthesia using a 23 mm Edwards-Sapien 3 bioprosthesis. The lower stent row of the TAVI was positioned under the lowest part of the SV frame to achieve stability of the implanted valve and to engage the thrombus. Intraoperative valve function was excellent showing minimal residual transvalvular gradient (Figure ) without paravalvular regurgitations on TOE, confirmed by aortic root angiography. She was extubated immediately after the procedure with an uneventful post-operative course. She was discharged home on Day 7 after TAVI with the following anticoagulation regime: acenocoumarol (target INR 2–3) and 100 mg aspirin once per day.(A and B) Valve-in-valve transcatheter valve implantation angiography and intra-OP gradient post-transcatheter valve implantation.
Follow-up and outcome
Post-operative echocardiography 5 days, 6, and 12 weeks after TAVI showed regular AV function with a constant minimal MPG (≤10 mmHg) and excluded valvular regurgitation. Computed tomography scan on Day 5 after TAVI confirmed perfect anatomical positioning of the AV with a completely circular shape of the annulus [diameter 20.4 × 20.1 mm (Figure )]. The course of NT-proBNP levels was 2260 ng/L before initial aortic valve replacement, 2892 ng/L before the ViV procedure and 1475 ng/L immediately thereafter (normal range <376 ng/L). The calculated systolic PAP decreased from 40 mmHg before ViV-TAVI to 30 mmHg. The patient presented with NYHA I 1 month after ViV-TAVI.
Discussion
To our knowledge this is the first report of a ViV-TAVI in a patient with a BVT of a self-expandable SV. There are sparse reports of documented SV thrombosis., The prevalence of BVT after SAVR or TAVI ranges between 7% and 23%. Notably, some studies reported no association with clinical symptoms, and revealed complete resolution of BVT after vitamin K antagonist treatment. Egbe et al. identified a 50% increase in MPG over 5 years as an independent predictor of BVT in 397 patients.Patient deterioration is probably associated with a combination of stenosis and regurgitation due to BVT as well as with the cardiac low-flow condition. The latter is a real challenge in heart failure management with preserved EF and is probably even more challenging when setting continuous right ventricular pacemaker stimulation resulting in a left bundle branch block. In our experience, these patients are extremely difficult to treat, as they have a high perioperative risk and often return with recurrent symptoms.The evolution of cardiac CT and the advent of three-dimensional TOE have provided appropriate imaging evidence of hypoattenuating leaflet thrombosis, and the reported data are steadily increasing.There are several technical aspects to be considered when planning and performing ViV-TAVI. First the exact brand, size and position of the index bioprosthesis volume rendering by CT angiography (Figure ) should be known for precise planning of the new prosthesis type and size. Dysfunctioning SV are considered a special condition, as they are self-expanding and the thrombosis may be associated with the initial anatomical valve position. Remaining calcifications of the native AV or a severely elliptic annulus may prevent proper expansion of the valve and thus pave the way for turbulence with increased shear stress or low-flow phenomena within the SV, which is prone to thrombosis. In our case, the SV was correctly sized and positioned. The form of the PERCEVAL-S® probably makes the use of high-profile TAVI less beneficial due to its difficult positioning (valve trapping or stent engagement) during implantation. We opted for a balloon-expandable valve to increase the circularity of the annulus after the procedure and to avoid tangling with the high frame of the PERCEVAL-S®.Moreover, the exact position of the thrombus and its mobility should be thoroughly examined due to the risk of embolism inherent in wire manipulations, which should not be underestimated during the procedure.
Conclusion
To summarize, we present a case of BVT of a SV treated by ViV-TAVI as an alternative to high-risk SAVR with excellent results in the short-term follow-up. However, mid- and long-term results are still outstanding, making this therapy’s perspective unclear. This strategy is feasible when specific valve type and anatomical conditions are exhaustively considered.Slide sets: A fully edited slide set detailing this case and suitable for local presentation is available online as Supplementary data.Consent: The author/s confirm that written consent for submission and publication of this case report including image(s) and associated text has been obtained from the patient in line with COPE guidance.Conflict of interest: none declared.Click here for additional data file.
Authors: Tina Leetmaa; Nicolaj C Hansson; Jonathon Leipsic; Kaare Jensen; Steen H Poulsen; Henning R Andersen; Jesper M Jensen; John Webb; Philipp Blanke; Mariann Tang; Bjarne L Nørgaard Journal: Circ Cardiovasc Interv Date: 2015-04 Impact factor: 6.546
Authors: Sabahattin Gündüz; Mehmet Özkan; Macit Kalçik; Ozan Mustafa Gürsoy; Mehmet Ali Astarcioğlu; Süleyman Karakoyun; Ahmet Çağri Aykan; Murat Biteker; Tayyar Gökdeniz; Hasan Kaya; Mahmut Yesin; Nilüfer Ekşi Duran; Deniz Sevinç; Tahsin Güneysu Journal: Circ Cardiovasc Imaging Date: 2015-12 Impact factor: 7.792
Authors: Joel Dunning; Haiyan Gao; John Chambers; Neil Moat; Gavin Murphy; Domenic Pagano; Simon Ray; James Roxburgh; Ben Bridgewater Journal: J Thorac Cardiovasc Surg Date: 2011-10 Impact factor: 5.209
Authors: Friedrich W Mohr; David Holzhey; Helge Möllmann; Andreas Beckmann; Christof Veit; Hans Reiner Figulla; Jochen Cremer; Karl-Heinz Kuck; Rüdiger Lange; Ralf Zahn; Stefan Sack; Gerhard Schuler; Thomas Walther; Friedhelm Beyersdorf; Michael Böhm; Gerd Heusch; Anne-Kathrin Funkat; Thomas Meinertz; Till Neumann; Konstantinos Papoutsis; Steffen Schneider; Armin Welz; Christian W Hamm Journal: Eur J Cardiothorac Surg Date: 2014-07-30 Impact factor: 4.191
Authors: Danny Dvir; John Webb; Stephen Brecker; Sabine Bleiziffer; David Hildick-Smith; Antonio Colombo; Fleur Descoutures; Christian Hengstenberg; Neil E Moat; Raffi Bekeredjian; Massimo Napodano; Luca Testa; Thierry Lefevre; Victor Guetta; Henrik Nissen; José-María Hernández; David Roy; Rui C Teles; Amit Segev; Nicolas Dumonteil; Claudia Fiorina; Michael Gotzmann; Didier Tchetche; Mohamed Abdel-Wahab; Federico De Marco; Andreas Baumbach; Jean-Claude Laborde; Ran Kornowski Journal: Circulation Date: 2012-10-10 Impact factor: 29.690
Authors: Raj R Makkar; Gregory Fontana; Hasan Jilaihawi; Tarun Chakravarty; Klaus F Kofoed; Ole De Backer; Federico M Asch; Carlos E Ruiz; Niels T Olsen; Alfredo Trento; John Friedman; Daniel Berman; Wen Cheng; Mohammad Kashif; Vladimir Jelnin; Chad A Kliger; Hongfei Guo; Augusto D Pichard; Neil J Weissman; Samir Kapadia; Eric Manasse; Deepak L Bhatt; Martin B Leon; Lars Søndergaard Journal: N Engl J Med Date: 2015-10-05 Impact factor: 91.245
Authors: Alexander C Egbe; Sorin V Pislaru; Patricia A Pellikka; Joseph T Poterucha; Hartzell V Schaff; Joseph J Maleszewski; Heidi M Connolly Journal: J Am Coll Cardiol Date: 2015-12-01 Impact factor: 24.094
Authors: Gregor Pache; Simon Schoechlin; Philipp Blanke; Stephan Dorfs; Nikolaus Jander; Chesnal D Arepalli; Michael Gick; Heinz-Joachim Buettner; Jonathon Leipsic; Mathias Langer; Franz-Josef Neumann; Philipp Ruile Journal: Eur Heart J Date: 2015-10-07 Impact factor: 29.983