Open-heart transcatheter aortic valve replacement in complex aortic valve reoperation: about a case series.

Laury Leveille1, Nicolas Jaussaud1, Alexis Theron1, Alberto Riberi1, Frederic Collart1.   

Abstract

INTRODUCTION: Aortic homograft and stentless aortic root are helpful in acute infective endocarditis of the aortic valve as biological conduit when total root replacement is required. Reoperation for failure of aortic homograft and stentless aortic root remains challenging for the surgeon as the entire root can be heavily calcified. CASE
PRESENTATION: Here, are reported, three cases of patients successfully treated with open-heart transcatheter aortic valve replacement (TAVR) whereas no other prosthesis was implantable due to a massively calcified homograft or stentless prosthesis. DISCUSSION: Open-heart TAVR avoided the risk of complete root replacement which is higher than redo aortic valve replacement (AVR). This rescue technique facilitated risky surgical procedure by combining the strengths of both TAVR and conventional AVR.

Entities:  

Keywords:  Aortic root; Aortic valve replacement; Case series; Heart valve replacement; Percutaneous; Transapical

Year:  2018        PMID: 31020142      PMCID: PMC6177095          DOI: 10.1093/ehjcr/yty064

Source DB:  PubMed          Journal:  Eur Heart J Case Rep        ISSN: 2514-2119


Reoperation for failure of homograft or stentless valve remains a technical challenge for the surgeon as the root calcifications can lead to technical difficulties during surgery. Open transcatheter aortic valve replacement is a safe and helpful procedure as it allows to avoid full aortic root reconstruction whereas no other prosthesis is implantable.

Introduction

Acute infective endocarditis of the aortic valve often requires total root replacement. Aortic homograft and stentless aortic root are helpful in this situation as biological conduit. As with any bioprosthetic valve, tissue calcification or degeneration may lead to a need for reoperation. Regarding homograft failure rate, it is between 10% and 25% within 15 years and nearly 50% by 20 years. After prior freestyle aortic valve replacement (AVR), 10- and 15-year rates for freedom from reoperation are 92% and 81%, respectively. In these cases, reoperation remains a technical challenge as the entire root can be heavily calcified. We report the successful treatment of three patients with failing aortic root homografts and stentless valve with ‘open TAVR’. Staphylococcus aureus native aortic valve endocarditis 22 mm aortic root homograft 40 years earlier: commissurotomy for congenital aortic stenosis 20 years later: 22 mm aortic root homograft for aortic stenosis Staphylococcus aureus native aortic valve endocarditis Aortic root replacement with 23 stentless bioprosthesis Ingravescent dyspnoea Transthoracic echocardiography (TTE)/transoesophageal echocardiography (TOE): severe aortic valve regurgitation Computed tomography (CT): severe calcified aortic root Dyspnoea, malaise TTE/TOE: severe aortic regurgitation CT: calcified aortic root homograft, clampable ascending aorta Dyspnoea evolving for 6 months TTE: severe aortic regurgitation ECG-gated heart CT: sinus and sinotubular calcification Attempt of conventional AVR Open transcatheter aortic valve replacement (TAVR) with 23 Sapien XT bioprosthesis TOE: severe periprosthetic regurgitation (PPR) Open TAVR with 26 Sapien XT bioprosthesis 2nd TOE: no PPR Attempt of RDVAR Open TAVR with 26 Sapien XT bioprosthesis TOE: no PPR Attempt of conventional AVR Open TAVR with 23 Sapien 3 bioprosthesis TOE: no PPR TTE: no PPR, mean aortic transvalvular gradient: 16 mmHg Discharge: 10th post-operative day TTE: no PPR, mean aortic transvalvular gradient: 13 mmHg Discharge: 10th post-operative day TTE: no PPR, mean aortic transvalvular gradient: 20 mmHg Discharge: 15th post-operative day

Case series

Patient 1

Patient 1 was a 53-year-old man with symptoms of ingravescent dyspnoea. Nineteen years previously, he had been operated on for native aortic valve endocarditis as a result of Staphylococcus aureus infection and received a 22 mm aortic root homograft. This endocarditis was complicated by a stroke and a spondylodiscitis. On examination, the patient was dyspnoeic. Cardiac auscultation revealed aortic diastolic and systolic murmurs Grades 2 and 3/6, respectively. Transthoracic echocardiography (TTE) and transoesophageal echocardiography (TOE) showed severe aortic valve regurgitation and moderate aortic stenosis. Computed tomography (CT) scan revealed a severe calcified aortic root (Figure ). Native ascending aorta remained uncalcified. Conventional redux AVR was planned in order to implant a bioprosthesis (patient refused a mechanical valve). After a general anaesthesia, a median sternotomy was performed. The procedure was performed under a normothermic cardiopulmonary bypass through the cannulation of the ascending aorta and the right atrial appendage. The aorta was clamped, and cold crystalloid cardioplegia was administered in a retrograde fashion. Aortotomy was performed above the distal suture line of the homograft. A massively calcified aortic root was documented. Because of the heavy calcification of the aortic annulus, the suture of a conventional aortic bioprosthesis was not possible and the replacement of the entire homograft was considered too risky. After excision of the aortic leaflets and annulus sizing, a TAVR was performed with a 23 Sapien XT bioprosthesis (Edwards Lifesciences, Inc.) using the Ascendra 24 Fr delivery system. After weaning from cardiopulmonary bypass, operative TOE was performed and showed a severe periprosthetic regurgitation (PPR). Therefore, the 23 Sapien XT was replaced by a 26 Sapien XT. The aortic cross clamp time (XCT) and the cardiopulmonary bypass time (CPBT) were 94 and 125 min, respectively. The second TOE showed no PPR. The post-operative course was uneventful. The patient was discharged on the 10th post-operative day. Mean transvalvular gradient was 16 mmHg, and no PPR was observed in TTE at discharge and 1 year after surgery.

Patient 2

The second patient was a 67-year-old female with severe aortic regurgitation as a result of aortic homograft degeneration. She was hospitalized in our cardiologic department for dyspnoea and malaise. Cardiac auscultation revealed an aortic diastolic murmur Grade 2/6. Forty years earlier, she underwent aortic commissurotomy for congenital aortic stenosis. Twenty years later, she received a 22 mm aortic root homograft for the recidivism of the aortic stenosis. This surgery was complicated by a post-operative conduction disorder that led to the implantation of a permanent pacemaker. Preoperative TTE and TOE showed an important aortic regurgitation and a posterior anastomotic false aneurysm. Euroscore II was 3.42%. The CT scan performed revealed a calcified aortic root homograft and a clampable ascending aorta. A rapid deployment AVR with an Intuity bioprosthesis was decided. As the sinotubular junction was too narrowed and too calcified (Figure ) to coast the device used to deploy the Intuity bioprosthesis, a TAVR was performed with a 26 Sapien XT. The perioperative TOE showed no PPR. MDCT anatomy of the aortic root (A) with cross-sectional area of the aortic annulus. Massively calcified coronary ostia (B) and sinotubular junction (C) (for Patient 1). MDCT, multidetector computed tomography. The aortic XCT and the CPBT were 67 and 87 min, respectively. The post-operative course was uneventful. Mean transvalvular gradient was 13 mmHg and no PPR was observed in TTE at discharge and 6 months after surgery.

Patient 3

The third patient was a 55-year-old female with a dyspnoea evolving for 6 months. Seventeen years earlier, she suffered a native aortic valve endocarditis with left atrial-aorta fistula as a result of a S. aureus infection. It was complicated by haemorrhagic cerebrovascular accident and resulted in left haemiplegia. She received a 23 mm Medtronic Freestyle stentless bioprosthesis implanted as a complete aortic root. On examination, cardiac auscultation revealed an aortic diastolic murmur Grade 4/6. Euroscore II was 4.53%. Preoperative TTE and TOE showed severe aortic regurgitation related to a tear of the non-coronary cusp. The ECG-gated cardiac CT scan revealed heavy calcifications of the sinus and sinotubular of the stentless valve. Aortic annulus area measurement was 320 mm2 and area at the level of the sinotubular junction was 314 (Figure ). The conclusion of the heart team, considering patient’s age, was to attempt a conventional AVR with a mechanical prosthesis. Operative view of the Sapien valve inserted in a heavily calcified aortic root. MDCT anatomy of the aortic root (A) with cross-section surface at the annular (B) and sinotubular junction (C) (for Patient 3). The aorta was opened above the stentless valve on the native aorta. The sinotubular junction was too stiff and narrow to be crossed by any mechanical or other conventional valves. A 23 mm Sapien 3 bioprosthesis was implanted using the 18 Fr Certitude Delivery System (Edwards Lifescience, Inc.). Intraoperative TOE showed no PPR. The aortic XCT and the CPBT were 35 and 71 min, respectively. Post-operative course was uneventful. Mean transvalvular gradient was 20 mmHg, and no PPR was observed in TTE at discharge and 1 month after surgery.

Discussion

The present study included three cases of high-risk patients who underwent successful open-heart transcatheter aortic valve replacement (TAVR) in complex aortic valve reoperation. Our main results are (i) open TAVR is a bail-out procedure that avoid the risk of complete root replacement in case of massively calcified homograft or stentless prosthesis. (ii) By combining the strengths of both TAVR and conventional AVR, open TAVR facilitates risky surgical procedure. Reoperation for failure of aortic homograft and stentless aortic root remains challenging for the cardiac surgeon. In literature, redo AVR presents less risks than redo aortic root replacement., Also, if possible, AVR is performed with conservation of the calcified aortic root. Nevertheless, this technique is only feasible in half the cases, if the homograft wall remained soft so a conventional aortotomy can be performed. When the aortic root presents major calcifications, the aortotomy has to be performed above the distal suture line of the conduit. Therefore, the procedure is performed afar from the aortic valve and an AVR may become difficult. This option can also be far-fetched, as in our three cases. The first reason is a narrow and calcified sinotubular junction. In fact, conventional or sutureless prosthesis are cumbersome and don’t climb down upon the aortic annulus. In this case, the only option is an aortic root replacement. However, the dissection and relocation of the coronary arteries can be troublesome and thereby lead to a significant increase of the CPBT and therefore the risk of post-operative morbidity and mortality. The second is the impossibility to cross a calcified annulus with the needles so the valve cannot be sutured. In young patients, transcatheter aortic valve implantation (TAVI) in first intention is rarely proposed because some doubts persist about its durability. Moreover, the dimensions of the homograft or the stentless valve can be too small to allow a TAVR. The reasons are manifold: the surface of the aortic annulus, coronary height, sinus width, or diameter of the sinotubular junction. In the three cases presented here, age of patients (between 53 and 67 years old) made us attempt a conventional AVR with a biologic or mechanical prosthesis. Firstly, for reasons of sustainability, on the other hand for technical reasons when the anatomy of the failing prosthesis was incompatible with TAVI. In the first case, the 23 sutureless bioprosthesis was too small and therefore responsible for severe PPR. It was replaced by a 26 bioprosthesis with good result. In this case, there was no preoperative annulus sizing to determine the size of the prosthesis before the procedure. In the last two cases, preoperative sizing was performed allowing the right size of prosthesis on the first attempt. One of the difficulties in implanting the valve is to deploy it at the level of the aortic ring. The achievement of this procedure in a hybrid room could allow to realize this deployment under scopic control after having marked the nadir of the three sinus of the aortic ring. On the other hand, the advantage over a conventional TAVI is that the native valve and so the possible asymmetric calcifications are removed. The risk of occurrence of PPR is therefore decreased. Furthermore, open TAVI reduces the risk of rupture of the aortic annulus and allows to slightly oversize the prosthesis when necessary; as in the latter case where a 23 mm Sapiens 3 was implanted whereas the sizing was too small to do it in conventional TAVI. In the same way, there is no risk of coronary occlusion since their permeability can be directly controlled once the prosthesis is in place. In complex aortic valve reoperation, TAVI changed our attitude. A pre-TAVI scan is realized to measure the aortic annulus and choose the size of the TAVI prosthesis that will be implanted. During the intervention, TAVI’s equipment is present in the room and the circulating nurse selected for the procedure is experienced in the techniques of preparation of the valve that will be used (crimping). The lower profile of TAVR devices vs. conventional valves allow to cross the stiff and calcified root and provide a safe, rapid, and technically easy solution to replace the aortic valve in this hostile surrounding. In complex aortic valve reoperation, open TAVI represents a very interesting option as a bail-out procedure when conventional valve/root replacement is not safely feasible. Consent: The author/s confirm that written consent for submission and publication of this case report including image(s) and associated text has been obtained from the patient in line with COPE guidance. Conflict of interest: F.C. and A.T. received consulting fees from Edwards Lifesciences.
PatientsOneTwoThree
History19 years earlier:

Staphylococcus aureus native aortic valve endocarditis

22 mm aortic root homograft

40 years earlier: commissurotomy for congenital aortic stenosis

20 years later: 22 mm aortic root homograft for aortic stenosis

17 years earlier:

Staphylococcus aureus native aortic valve endocarditis

Aortic root replacement with 23 stentless bioprosthesis

Clinic and para clinic

Ingravescent dyspnoea

Transthoracic echocardiography (TTE)/transoesophageal echocardiography (TOE): severe aortic valve regurgitation

Computed tomography (CT): severe calcified aortic root

Dyspnoea, malaise

TTE/TOE: severe aortic regurgitation

CT: calcified aortic root homograft, clampable ascending aorta

Dyspnoea evolving for 6 months

TTE: severe aortic regurgitation

ECG-gated heart CT: sinus and sinotubular calcification

Surgery

Attempt of conventional AVR

Open transcatheter aortic valve replacement (TAVR) with 23 Sapien XT bioprosthesis

TOE: severe periprosthetic regurgitation (PPR)

Open TAVR with 26 Sapien XT bioprosthesis

2nd TOE: no PPR

Attempt of RDVAR

Open TAVR with 26 Sapien XT bioprosthesis

TOE: no PPR

Attempt of conventional AVR

Open TAVR with 23 Sapien 3 bioprosthesis

TOE: no PPR

Outcomes

TTE: no PPR, mean aortic transvalvular gradient: 16 mmHg

Discharge: 10th post-operative day

TTE: no PPR, mean aortic transvalvular gradient: 13 mmHg

Discharge: 10th post-operative day

TTE: no PPR, mean aortic transvalvular gradient: 20 mmHg

Discharge: 15th post-operative day

  7 in total

1.  Reoperation is not an independent predictor of mortality during aortic valve surgery.

Authors:  Piroze M Davierwala; Michael A Borger; Tirone E David; Vivek Rao; Manjula Maganti; Terrence M Yau
Journal:  J Thorac Cardiovasc Surg       Date:  2006-02       Impact factor: 5.209

2.  Risk of reoperative valve replacement for failed mitral and aortic bioprostheses.

Authors:  C W Akins; M J Buckley; W M Daggett; A D Hilgenberg; G J Vlahakes; D F Torchiana; J C Madsen
Journal:  Ann Thorac Surg       Date:  1998-06       Impact factor: 4.330

Review 3.  Time to Explore Transcatheter Aortic Valve Replacement in Younger, Low-Risk Patients.

Authors:  Lars Sondergaard
Journal:  JACC Cardiovasc Interv       Date:  2016-10-12       Impact factor: 11.195

4.  Cross-clamp time is an independent predictor of mortality and morbidity in low- and high-risk cardiac patients.

Authors:  Nael Al-Sarraf; Lukman Thalib; Anne Hughes; Maighread Houlihan; Michael Tolan; Vincent Young; Eillish McGovern
Journal:  Int J Surg       Date:  2010-10-20       Impact factor: 6.071

5.  Impact of paravalvular leakage on outcome in patients after transcatheter aortic valve implantation.

Authors:  Mariuca Vasa-Nicotera; Jan-Malte Sinning; Derek Chin; Tiong Keng Lim; Tomasz Spyt; Hasan Jilaihawi; Eberhard Grube; Nikos Werner; Georg Nickenig; Jan Kovac
Journal:  JACC Cardiovasc Interv       Date:  2012-08       Impact factor: 11.195

6.  Long-term clinical outcomes 15 years after aortic valve replacement with the Freestyle stentless aortic bioprosthesis.

Authors:  David S Bach; Neal D Kon
Journal:  Ann Thorac Surg       Date:  2013-10-17       Impact factor: 4.330

7.  Redo aortic root surgery for failure of an aortic homograft is a major technical challenge.

Authors:  Thomas M Joudinaud; Franck Baron; Richard Raffoul; Bruno Pagis; Mathieu Vergnat; Caroline Parisot; Ulrik Hvass; Patrick R Nataf
Journal:  Eur J Cardiothorac Surg       Date:  2008-03-06       Impact factor: 4.191

  7 in total
  2 in total

1.  TAVI-in-homograft (TiH): open transcatheter aortic valve replacement in calcified aortic homograft case reports.

Authors:  Marco Gennari; Ilaria Giambuzzi; Gianluca Polvani; Marco Agrifoglio
Journal:  J Cardiothorac Surg       Date:  2019-11-27       Impact factor: 1.637

2.  Transcatheter aortic valve replacement using the ACURATE NEOTM valve to treat pure aortic regurgitation in a degenerated aortic homograft valve.

Authors:  Pierre Deharo; Nicolas Jaussaud; Frédéric Collart; Thomas Cuisset
Journal:  Eur Heart J Case Rep       Date:  2020-01-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.