Cross-clamp time is an independent predictor of mortality and morbidity in low- and high-risk cardiac patients.

Nael Al-Sarraf1, Lukman Thalib, Anne Hughes, Maighread Houlihan, Michael Tolan, Vincent Young, Eillish McGovern.   

Abstract

OBJECTIVES: We sought to assess the effects of aortic cross-clamp time (XCL) on outcome following cardiac surgery in low- and high-risk patients.
METHODS: This is a retrospective review of prospectively collected departmental data of all patients who underwent cardiac surgery over 8-year period. Our cohort consisted of 3799 consecutive patients subdivided into low-risk (Euro SCORE < 6, n = 2691, 71%) and high-risk (Euro SCORE ≥ 6, n = 1108, 29%). Each class was further stratified into three groups based on their corresponding XCL time. Group 1 (XCL ≤ 60 min), group 2 (XCL > 60 but ≤ 90 min) and group 3 (XCL >90 min). Postoperative morbidity and in-hospital mortality were analysed.
RESULTS: Univariate analysis showed the following to be significantly associated with increased XCL time in both low- and high-risk patients: low cardiac output, prolonged ventilation time, renal complications, prolonged hospital stay, blood transfusion and increased mortality (p < 0.05). By using multiple logistic regression, aortic XCL time >60 min was independent risk factor for low cardiac output, prolonged ventilation, renal complication, blood transfusion, mortality and prolonged hospital stay in both groups. By using XCL time as a continuous variable, an incremental increase of 1 min interval in XCL time was associated with a 2% increase in mortality in both groups.
CONCLUSION: Prolonged cross-clamp time significantly correlates with major post-operative morbidity and mortality in both low- and high-risk patients. This effect increases with increasing XCL time. Prior knowledge on this effect can help in preventing some of these complications. Copyright Â
© 2010 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20965288     DOI: 10.1016/j.ijsu.2010.10.007

Source DB:  PubMed          Journal:  Int J Surg        ISSN: 1743-9159            Impact factor:   6.071


  48 in total

Review 1.  Sutureless aortic valve replacement.

Authors:  Marco Di Eusanio; Kevin Phan
Journal:  Ann Cardiothorac Surg       Date:  2015-03

Review 2.  Sutureless aortic valve replacement: a systematic review and meta-analysis.

Authors:  Kevin Phan; Yi-Chin Tsai; Nithya Niranjan; Denis Bouchard; Thierry P Carrel; Otto E Dapunt; Harald C Eichstaedt; Theodor Fischlein; Borut Gersak; Mattia Glauber; Axel Haverich; Martin Misfeld; Peter J Oberwalder; Giuseppe Santarpino; Malakh Lal Shrestha; Marco Solinas; Marco Vola; Tristan D Yan; Marco Di Eusanio
Journal:  Ann Cardiothorac Surg       Date:  2015-03

Review 3.  Right anterior minithoracotomy for aortic valve replacement.

Authors:  Antonio Miceli; Matteo Ferrarini; Mattia Glauber
Journal:  Ann Cardiothorac Surg       Date:  2015-01

Review 4.  Minimally invasive aortic valve surgery: state of the art and future directions.

Authors:  Mattia Glauber; Matteo Ferrarini; Antonio Miceli
Journal:  Ann Cardiothorac Surg       Date:  2015-01

5.  Hospital cost savings and other advantages of sutureless vs stented aortic valves for intermediate-risk elderly patients.

Authors:  Tomoyuki Minami; Sarah Sainte; Herbert De Praetere; Filip Rega; Willem Flameng; Peter Verbrugghe; Bart Meuris
Journal:  Surg Today       Date:  2017-04-06       Impact factor: 2.549

6.  Minimally invasive aortic valve replacement-where are we?

Authors:  Sameer Arora; John P Vavalle
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

Review 7.  Ten-year experience with the Perceval S sutureless prosthesis: lessons learned and future perspectives.

Authors:  Vincent Chauvette; Amine Mazine; Denis Bouchard
Journal:  J Vis Surg       Date:  2018-05-03

8.  Sutureless aortic valve replacement in high risk patients neutralizes expected worse hospital outcome: A clinical and economic analysis.

Authors:  Emmanuel Villa; Margherita Dalla Tomba; Antonio Messina; Andrea Trenta; Federico Brunelli; Marco Cirillo; Zean Mhagna; Giovanni Alfonso Chiariello; Giovanni Troise
Journal:  Cardiol J       Date:  2018-09-20       Impact factor: 2.737

9.  Tissue Doppler imaging detects impaired biventricular performance shortly after congenital heart defect surgery.

Authors:  Liselotte M Klitsie; Mark G Hazekamp; Arno A W Roest; Annelies E Van der Hulst; Birthe J Gesink-van der Veer; Irene M Kuipers; Nico A Blom; Arend D J Ten Harkel
Journal:  Pediatr Cardiol       Date:  2012-09-22       Impact factor: 1.655

10.  Pilot study investigating the feasibility of mitral valve repair without aortic cross-clamping and cardioplegia.

Authors:  Wanda J Gordon-Evans; John P Carney; Mathew T Lahti; Richard W Bianco
Journal:  Can J Vet Res       Date:  2020-04       Impact factor: 1.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.