Literature DB >> 31005158

Improved visualization of the coronary arteries using motion correction during vasodilator stress CT myocardial perfusion imaging.

Bhavna Balaney1, Mani Vembar2, Michael Grass3, Amita Singh1, Keigo Kawaji1, Luis Landeras1, Jonathan Chung1, Victor Mor-Avi1, Amit R Patel4.   

Abstract

BACKGROUND: Vasodilator stress computed tomography perfusion (sCTP) imaging is complementary to coronary CT angiography (CCTA), used to determine the hemodynamic significance of coronary artery disease. However, it requires a separate image acquisition due to motion artifacts caused by higher heart rates during stress, resulting in increased iodine contrast dose and radiation. We sought to determine whether a novel motion correction algorithm applied to stress images would improve the visualization of the coronary arteries to potentially allow CCTA + sCTP evaluation in a single scan.
METHODS: 28 patients referred for clinically indicated CCTA (iCT, Philips) underwent sCTP imaging (retrospective-gating with dose modulation; 100 kVp and 250 mA; 5.2 ± 4.3 mSv) after regadenoson (0.4 mg, Astellas). Stress images were reconstructed using standard filtered back-projection (FBP) and also processed to generate interaction-free coronary motion-compensated back-projection reconstructions (MCR). Each coronary artery from standard FBP and MCR images was viewed side-by-side by a reader blinded to the reconstruction technique, who graded severity of motion artifact by segment (scale 0-5, with 3 as the threshold for diagnostic quality) and to measure signal-to-noise and contrast-to-noise ratios (SNR, CNR).
RESULTS: Visualization scores were higher with MCR for all coronary segments, including 14/86 (16%) segments deemed as non-diagnostic on FBP images. SNR (7 ± 2) and CNR (15 ± 8) were unchanged by motion-correction (7 ± 3, p = 0.88 and 15 ± 5, p = 0.94, respectively).
CONCLUSIONS: MCR improves the visualization of coronary anatomy on sCTP images without degrading image characteristics. This algorithm is an important step towards the combined assessment of coronary anatomy and myocardial perfusion in a single scan, which will reduce study time, radiation exposure and contrast dose.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Coronary computed tomography; Myocardial perfusion imaging; Noninvasive coronary angiography; Vasodilator stress testing

Mesh:

Substances:

Year:  2019        PMID: 31005158      PMCID: PMC8240649          DOI: 10.1016/j.ejrad.2019.02.010

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  22 in total

1.  Fully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac CT reconstruction.

Authors:  Alfonso A Isola; Michael Grass; Wiro J Niessen
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

Review 2.  Prognostic value of cardiac computed tomography angiography: a systematic review and meta-analysis.

Authors:  Edward A Hulten; Salvatore Carbonaro; Sara P Petrillo; Joshua D Mitchell; Todd C Villines
Journal:  J Am Coll Cardiol       Date:  2010-12-08       Impact factor: 24.094

3.  Aperture weighted cardiac reconstruction for cone-beam CT.

Authors:  P Koken; M Grass
Journal:  Phys Med Biol       Date:  2006-07-06       Impact factor: 3.609

4.  Combined coronary angiography and myocardial perfusion by computed tomography in the identification of flow-limiting stenosis - The CORE320 study: An integrated analysis of CT coronary angiography and myocardial perfusion.

Authors:  Tiago A Magalhães; Satoru Kishi; Richard T George; Armin Arbab-Zadeh; Andrea L Vavere; Christopher Cox; Matthew B Matheson; Julie M Miller; Jeffrey Brinker; Marcelo Di Carli; Frank J Rybicki; Carlos E Rochitte; Melvin E Clouse; João A C Lima
Journal:  J Cardiovasc Comput Tomogr       Date:  2015-03-21

5.  Systolic time intervals in heart failure in man.

Authors:  A M Weissler; W S Harris; C D Schoenfeld
Journal:  Circulation       Date:  1968-02       Impact factor: 29.690

6.  Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

Authors:  Shuai Leng; Lifeng Yu; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiology       Date:  2015-04-10       Impact factor: 11.105

7.  Effect of the Motion Correction Technique on Image Quality at 320-Detector Computed Tomography Coronary Angiography in Patients With Atrial Fibrillation.

Authors:  Fuminari Tatsugami; Toru Higaki; Wataru Fukumoto; Yoko Kaichi; Makoto Iida; Chikako Fujioka; Masao Kiguchi; Yasuki Kihara; Kazuo Awai
Journal:  J Comput Assist Tomogr       Date:  2016 Jul-Aug       Impact factor: 1.826

8.  Nonrigid registration-based coronary artery motion correction for cardiac computed tomography.

Authors:  Roshni Bhagalia; Jed D Pack; James V Miller; Maria Iatrou
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

9.  Effect of intracycle motion correction algorithm on image quality and diagnostic performance of computed tomography coronary angiography in patients with suspected coronary artery disease.

Authors:  Patricia Carrascosa; Alejandro Deviggiano; Carlos Capunay; Macarena C De Zan; Alejandro Goldsmit; Gaston A Rodriguez-Granillo
Journal:  Acad Radiol       Date:  2014-10-03       Impact factor: 3.173

10.  Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography.

Authors:  Ron Blankstein; Leon D Shturman; Ian S Rogers; Jose A Rocha-Filho; David R Okada; Ammar Sarwar; Anand V Soni; Hiram Bezerra; Brian B Ghoshhajra; Milena Petranovic; Ricardo Loureiro; Gudrun Feuchtner; Henry Gewirtz; Udo Hoffmann; Wilfred S Mamuya; Thomas J Brady; Ricardo C Cury
Journal:  J Am Coll Cardiol       Date:  2009-09-15       Impact factor: 24.094

View more
  1 in total

1.  Artificial Intelligence to Assist in Exclusion of Coronary Atherosclerosis During CCTA Evaluation of Chest Pain in the Emergency Department: Preparing an Application for Real-world Use.

Authors:  Richard D White; Barbaros S Erdal; Mutlu Demirer; Vikash Gupta; Matthew T Bigelow; Engin Dikici; Sema Candemir; Mauricio S Galizia; Jessica L Carpenter; Thomas P O'Donnell; Abdul H Halabi; Luciano M Prevedello
Journal:  J Digit Imaging       Date:  2021-03-31       Impact factor: 4.903

  1 in total