Abstract

PURPOSE: Cardiac computed tomography is a rapidly emerging technique for noninvasive diagnosis of cardiovascular diseases. Nevertheless, the cardiac motion continues to be a limiting factor. Electrocardiogram-gated cardiac computed tomography reconstruction methods yield excellent results, but these are limited in their temporal resolution due to the mechanical movement of the gantry, and lead to residual motion blurring artifacts. If the motion of the cardiac region of interest is determined, motion compensated gated reconstructions can be applied to reduce motion artifacts. In this paper it is shown that elastic image registration methods can be an accurate solution to determine the cardiac motion. A method, which combines elastic registration and iterative computed tomography reconstruction methods delivering motion-corrected images of a chosen cardiac region of interest, is introduced.
METHODS: Using a gated four-dimensional region of interest image data set, a fully automatic elastic image registration is applied to recover a cardiac displacement field from a reference phase to a number of phases within the RR interval. Here, a stochastic optimizer and multiresolution approach are adopted to speed up the registration process. Subsequently, motion-compensated iterative reconstruction using the determined motion field is carried out. For the image representation volume-adapted spherical basis functions (blobs) are used to take the volume change caused by a divergent motion vector field into account.
RESULTS: The method is evaluated on phantom data and on four clinical data sets at a strong cardiac motion phase. Comparing the method to standard gated iterative reconstruction results shows that motion compensation strongly improves the image quality in these phases. A qualitative and quantitative accuracy study is presented for the estimated cardiac motion field. For the first time a blob-volume adaptation is applied on clinical data, and in the case of divergent motion it yields improved image quality.
CONCLUSIONS: A fully automatic local cardiac motion compensated gated iterative method with volume-adapted blobs is proposed. The method leads to excellent motion-corrected images which outperform nonmotion corrected results in phases of strong cardiac motion. In clinical cases, a volume-dependent blob-footprint adaptation proves to be a good solution to take care of the change in the blob volume caused by a divergent motion field.

Entities:  

Mesh:

Year:  2010        PMID: 20384245     DOI: 10.1118/1.3301600

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Improved visualization of the coronary arteries using motion correction during vasodilator stress CT myocardial perfusion imaging.

Authors:  Bhavna Balaney; Mani Vembar; Michael Grass; Amita Singh; Keigo Kawaji; Luis Landeras; Jonathan Chung; Victor Mor-Avi; Amit R Patel
Journal:  Eur J Radiol       Date:  2019-03-02       Impact factor: 3.528

2.  The role of acquisition and quantification methods in myocardial blood flow estimability for myocardial perfusion imaging CT.

Authors:  Brendan L Eck; Raymond F Muzic; Jacob Levi; Hao Wu; Rachid Fahmi; Yuemeng Li; Anas Fares; Mani Vembar; Amar Dhanantwari; Hiram G Bezerra; David L Wilson
Journal:  Phys Med Biol       Date:  2018-09-13       Impact factor: 3.609

3.  Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT.

Authors:  K Müller; A K Maier; C Schwemmer; G Lauritsch; S De Buck; J-Y Wielandts; J Hornegger; R Fahrig
Journal:  Phys Med Biol       Date:  2014-05-20       Impact factor: 3.609

4.  Validation of DRAMMS among 12 Popular Methods in Cross-Subject Cardiac MRI Registration.

Authors:  Yangming Ou; Dong Hye Ye; Kilian M Pohl; Christos Davatzikos
Journal:  Biomed Image Regist Proc       Date:  2012-07

5.  A fully four-dimensional, iterative motion estimation and compensation method for cardiac CT.

Authors:  Qiulin Tang; Jochen Cammin; Somesh Srivastava; Katsuyuki Taguchi
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

6.  Three-dimensional regions-of-interest-based intra-operative four-dimensional soft tissue perfusion imaging using a standard x-ray system with no gantry rotation: A simulation study for a proof of concept.

Authors:  Katsuyuki Taguchi; Thomas J Sauer; W Paul Segars; Eric C Frey; Jingyan Xu; Eleni Liapi; J Webster Stayman; Kelvin Hong; Ferdinand K Hui; Mathias Unberath; Yong Du
Journal:  Med Phys       Date:  2020-10-22       Impact factor: 4.071

Review 7.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

8.  Correction of patient motion in cone-beam CT using 3D-2D registration.

Authors:  S Ouadah; M Jacobson; J W Stayman; T Ehtiati; C Weiss; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-09       Impact factor: 3.609

9.  Interventional heart wall motion analysis with cardiac C-arm CT systems.

Authors:  Kerstin Müller; Andreas K Maier; Yefeng Zheng; Yang Wang; Günter Lauritsch; Chris Schwemmer; Christopher Rohkohl; Joachim Hornegger; Rebecca Fahrig
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

10.  Lesion quantification and detection in myocardial (18)F-FDG PET using edge-preserving priors and anatomical information from CT and MRI: a simulation study.

Authors:  Anna Turco; Johan Nuyts; Olivier Gheysens; Jürgen Duchenne; Jens-Uwe Voigt; Piet Claus; Kathleen Vunckx
Journal:  EJNMMI Phys       Date:  2016-06-17