Geant4 physics list comparison for the simulation of phase-contrast mammography (XPulse project).

V Beaudoux1, G Blin2, B Barbrel3, G Kantor4, C Zacharatou4.   

Abstract

PURPOSE: Breast cancer is the most frequent cancer in women. Early and accurate detection of the disease is a major factor in patient survival. To this end, phase-contrast imaging has gained significant interest in recent years. The aim of this work was to validate the physics models of a Geant4 mammography imaging simulation (in the context of the XPulse project) by comparing to EGSnrc results.
METHODS: We used three Geant4 electromagnetic physics lists of the version 10.4 of the toolkit: Standard, Livermore and Penelope. We calculated energy distributions in homogeneous and inhomogeneous phantoms and breast doses in DICOM images. The simulations used photon beams of energies 20-100 keV. The Geant4 calculations were compared with EGSnrc/DOSXYZnrc simulations.
RESULTS: We found a very good agreement between the Standard Electromagnetic option 4 and Livermore Physics Lists (within 1% for all beam energies). Larger differences were found between Standard Electromagnetic option 4 and Penelope Physics Lists (about 4%). The agreement of longitudinal energy distributions between Geant4 Standard Electromagnetic option 4 and EGSnrc was good in water and light biological materials, but important discrepancies were found in heavy elements. We confirmed with both codes that dose to the breast is minimal at beam energy around 60 keV.
CONCLUSIONS: Overall, we found good agreement between the option 4 of the Standard Electromagnetic physics list and Livermore physics lists of Geant4, as well as EGSnrc for materials relevant to mammography screening. Further investigations are needed for the case of heavier materials.
Copyright © 2019 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Geant4; Mammography; Monte Carlo

Mesh:

Substances:

Year:  2019        PMID: 31000088     DOI: 10.1016/j.ejmp.2019.03.026

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

1.  Radioembolization Dosimetry with Total-Body 90Y PET.

Authors:  Gustavo Costa; Benjamin Spencer; Negar Omidvari; Cameron Foster; Michael Rusnak; Heather Hunt; Denise T Caudle; Rex T Pillai; Catherine Tram Vu; Emilie Roncali
Journal:  J Nucl Med       Date:  2021-11-18       Impact factor: 11.082

2.  Monte Carlo simulation of digital photon counting PET.

Authors:  Julien Salvadori; Joey Labour; Freddy Odille; Pierre-Yves Marie; Jean-Noël Badel; Laëtitia Imbert; David Sarrut
Journal:  EJNMMI Phys       Date:  2020-04-25

3.  Yttrium-90 quantitative phantom study using digital photon counting PET.

Authors:  Joey Labour; Philippe Boissard; David Sarrut; Jean-Noël Badel; Thomas Baudier; Fouzi Khayi; David Kryza; Pascale Veyrat Durebex; Sandrine Parisse-Di Martino; Thomas Mognetti
Journal:  EJNMMI Phys       Date:  2021-07-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.