Literature DB >> 30993431

Dose to the interventional radiologist in CTF-guided procedures.

J G Alves1,2, S Sarmento3,4, J S Pereira5,6, M F Pereira5,6, M J Sousa7, L Cunha3,4, A Dias3,4, A D Oliveira5,6, J V Cardoso5, L M Santos5, J Lencart3, M Gouvêa8, J A M Santos3,4.   

Abstract

The aim of this work was to assess the occupational dose received by an interventional radiologist (IR) during computed tomography fluoroscopy (CTF)-guided procedures; to identify the most exposed areas of the body including the hands and fingers; to suggest recommendations for individual monitoring; and to improve radiation safety of the practice. A total of 53 CTF-guided procedures were studied. Twelve whole-body dosimeters were worn by the IR in each procedure for the assessment of the personal dose equivalent, Hp(10), on the chest, waist, and back, both over and under the lead apron, as well as the personal dose equivalent, Hp(0.07), on both arms, knees, and feet. Special gloves with casings to fit extremity dosimeters were prepared to assess Hp(0.07) to the fingers. The measured chest dose values were higher than those on the waist and back; the dominant hand or the left side was the most exposed. In general, the ring, middle, and index fingers of the dominant hand were the most exposed (maximum in the 36-39 mSv range), while wrist dose was negligible compared to finger doses. Based on the results obtained the following recommendations are suggested: protective devices (lead aprons, thyroid shield, and goggles) should be worn; Hp(10) should be assessed at the chest level both above and below the lead apron; finger doses can be measured on the basis of each middle finger; the arm closer to the beam should be monitored; and finally, a wrist dosimeter will not provide useful information.

Keywords:  CTF; Dosimetry; Interventional radiology; Radiation dose assessment

Year:  2019        PMID: 30993431     DOI: 10.1007/s00411-019-00792-3

Source DB:  PubMed          Journal:  Radiat Environ Biophys        ISSN: 0301-634X            Impact factor:   1.925


  21 in total

1.  CT fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure.

Authors:  S G Silverman; K Tuncali; D F Adams; R D Nawfel; K H Zou; P F Judy
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

2.  Real-time CT and CT fluoroscopy.

Authors:  N Keat
Journal:  Br J Radiol       Date:  2001-12       Impact factor: 3.039

3.  CT fluoroscopy-guided intervention: marked reduction of scattered radiation dose to the physician's hand by use of a lead plate and an improved I-I device.

Authors:  T Irie; M Kajitani; Y Itai
Journal:  J Vasc Interv Radiol       Date:  2001-12       Impact factor: 3.464

4.  FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.

Authors:  J Pereira; M F Pereira; S Rangel; M Saraiva; L M Santos; J V Cardoso; J G Alves
Journal:  Radiat Prot Dosimetry       Date:  2015-10-25       Impact factor: 0.972

5.  Detection and determination limits for thermoluminescence dosimetry.

Authors:  C R Hirning
Journal:  Health Phys       Date:  1992-03       Impact factor: 1.316

6.  Guidance with real-time CT fluoroscopy: early clinical experience.

Authors:  K Katada; R Kato; H Anno; Y Ogura; S Koga; Y Ida; M Sato; K Nonomura
Journal:  Radiology       Date:  1996-09       Impact factor: 11.105

7.  Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders.

Authors:  R Kato; K Katada; H Anno; S Suzuki; Y Ida; S Koga
Journal:  Radiology       Date:  1996-11       Impact factor: 11.105

8.  Difficult thoracic lesions: CT-guided biopsy experience in 150 cases.

Authors:  E vanSonnenberg; G Casola; M Ho; C C Neff; R R Varney; G R Wittich; R Christensen; P J Friedman
Journal:  Radiology       Date:  1988-05       Impact factor: 11.105

9.  Percutaneous needle biopsy of localized pulmonary, mediastinal, and pleural diseased tissue with an automatic disposable guillotine soft-tissue needle. Preliminary results.

Authors:  M M Noppen; J De Mey; M Meysman; B Opdebeeck; W G Vincken; M Osteaux
Journal:  Chest       Date:  1995-06       Impact factor: 9.410

10.  The use of needle holders in CTF guided biopsies as a dose reduction tool.

Authors:  Sandra Sarmento; Joana S Pereira; Maria José Sousa; Luís T Cunha; Anabela G Dias; Miguel F Pereira; Augusto D Oliveira; João V Cardoso; Luís M Santos; João A M Santos; João G Alves
Journal:  J Appl Clin Med Phys       Date:  2017-11-29       Impact factor: 2.102

View more