Literature DB >> 26503857

FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.

J Pereira1, M F Pereira2, S Rangel2, M Saraiva2, L M Santos2, J V Cardoso2, J G Alves3.   

Abstract

Thermoluminescence dosemeters are widely used in individual and environmental monitoring. The aim of this work was to compare the thermal stability of dosemeters of the Ext-Rad and whole-body card types with LiF:Mg,Ti and LiF:Mg,Cu,P detectors stored at different temperatures and periods. The dosemeters were stored at 0°C, room temperature and 40°C for periods that lasted 8, 30, 45, 90 and 120 d. In general, TLD-100H detectors present higher TL signal stability than TLD-100 detectors. The intensity of the signal remained constant for both materials for storage periods at 0°C. At RT the same results was observed for TLD-100H. For TLD-100 detectors, a maximum variation of 22 % was registered for the longest period. At 40°C the TL signal decreased with storage time for both detectors. The TL signal of TLD-100H detectors presented maximum variations of 12 % whereas for TLD-100 detectors, larger variations of 25 % were observed.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26503857     DOI: 10.1093/rpd/ncv445

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.

Authors:  Mariana Baptista; Salvatore Di Maria; Sandra Vieira; Joana Santos; Joana Pereira; Miguel Pereira; Pedro Vaz
Journal:  Radiat Environ Biophys       Date:  2018-11-03       Impact factor: 1.925

2.  Dose to the interventional radiologist in CTF-guided procedures.

Authors:  J G Alves; S Sarmento; J S Pereira; M F Pereira; M J Sousa; L Cunha; A Dias; A D Oliveira; J V Cardoso; L M Santos; J Lencart; M Gouvêa; J A M Santos
Journal:  Radiat Environ Biophys       Date:  2019-04-16       Impact factor: 1.925

3.  Comparison of 3DCRT and IMRT out-of-field doses in pediatric patients using Monte Carlo simulations with treatment planning system calculations and measurements.

Authors:  Ana Cravo Sá; Andreia Barateiro; Bryan P Bednarz; Pedro Almeida; Pedro Vaz; Tiago Madaleno
Journal:  Front Oncol       Date:  2022-08-05       Impact factor: 5.738

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.