Literature DB >> 30988567

Utilisation of Flow-cytometry in the Diagnosis of Auto Immune Haemolytic Anaemia.

Jitender Mohan Khunger1, H P Pati2, M Mahapatra2, Arjun Khunger3.   

Abstract

Auto Immune Haemolytic Anaemia (AIHA) is one of the most common types of acquired haemolytic anaemias. Its main cause is auto-antibody mediated rapid destruction of Red Blood Cells (RBCs). Demonstration of a positive Direct Antiglobulin Test also known as Coomb's test, against these autoantibodies is the crucial serological assay in the diagnosis of AIHA. This routinely used test has the disadvantage of low sensitivity and does not detect low levels of red cell auto antibodies leading to false negative results sometimes. Flow cytometry can effectively diagnose such patients with low levels of autoantibodies. This study was carried out in a tertiary care center, where patients with suspected AIHA were studied during 2 years period. Blood samples of suspected patients of AIHA were tested by both Gel Card Test and by Flow-cytometry for detection of RBC bound IgG. A total of 50 patients with suspected diagnosis of AIHA were studied by flow-cytometry as well as by Gel card test for detection of RBC bound IgG. Out of these 50 cases, 41 cases have turned out to be positive and 9 were negative by flow-cytometry. By Gel card test, out of 50 cases, 34 were positive and 16 were negative. Therefore, there were 7 cases which were negative for RBC bound IgG by Gel card test and these were positive by flow-cytometry. Flow-cytometry is a reliable and more sensitive method and can be used as a new routine diagnostic technique for AIHA.

Entities:  

Keywords:  Antibodies; Autoimmune hemolytic anemia (AIHA); Flow-cytometry (FCM); Immunoglobulin; Red blood Cell (RBC)

Year:  2018        PMID: 30988567      PMCID: PMC6439060          DOI: 10.1007/s12288-018-1017-y

Source DB:  PubMed          Journal:  Indian J Hematol Blood Transfus        ISSN: 0971-4502            Impact factor:   0.900


  22 in total

Review 1.  Applications of flow cytofluorometry to red blood cell immunology.

Authors:  G Garratty; P A Arndt
Journal:  Cytometry       Date:  1999-12-15

2.  Direct-antiglobulin-test-negative immune haemolytic anaemia and thrombocytopenia in a patient with Hodgkin's disease.

Authors:  H Kondo; T Oyamada; A Mori; H Sumi; K Kurosu; E Kajii; A Mikata
Journal:  Acta Haematol       Date:  2001       Impact factor: 2.195

3.  Detection of red blood cell-bound immunoglobulin G by flow cytometry and its application in the diagnosis of autoimmune hemolytic anemia.

Authors:  Z Wang; J Shi; Y Zhou; C Ruan
Journal:  Int J Hematol       Date:  2001-02       Impact factor: 2.490

4.  A persistent severe autoimmune hemolytic anemia despite apparent direct antiglobulin test negativization.

Authors:  E Biagi; G Assali; F Rossi; M Jankovic; B Nicolini; A Balduzzi
Journal:  Haematologica       Date:  1999-11       Impact factor: 9.941

5.  Coombs--negative immune hemolytic anemia.

Authors:  B C Gilliland
Journal:  Semin Hematol       Date:  1976-10       Impact factor: 3.851

6.  Application of flow cytometry in detection of red-cell-bound IgG in Coombs-negative AIHA.

Authors:  Rajendra Chaudhary; Sudipta S Das; Ritu Gupta; Dheeraj Khetan
Journal:  Hematology       Date:  2006-08       Impact factor: 2.269

7.  A preliminary comparison of flow cytometry and tube agglutination assays in detecting red blood cell-associated C3d.

Authors:  D F Stroncek; J M Njoroge; J L Procter; R W Childs; J Miller
Journal:  Transfus Med       Date:  2003-02       Impact factor: 2.019

Review 8.  Autoimmune hemolytic anemia.

Authors:  Bradley C Gehrs; Richard C Friedberg
Journal:  Am J Hematol       Date:  2002-04       Impact factor: 10.047

9.  A newly developed gel centrifugation test for quantification of RBC-bound IgG antibodies and their subclasses IgG1 and IgG3: comparison with flow cytometry.

Authors:  Rainer Lynen; Olaf Krone; Tobias J Legler; Michael Köhler; Wolfgang R Mayr
Journal:  Transfusion       Date:  2002-05       Impact factor: 3.157

10.  An automatable format for accurate immunohematology testing by flow cytometry.

Authors:  John D Roback; Sheilagh Barclay; Christopher D Hillyer
Journal:  Transfusion       Date:  2003-07       Impact factor: 3.157

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.