Literature DB >> 12581452

A preliminary comparison of flow cytometry and tube agglutination assays in detecting red blood cell-associated C3d.

D F Stroncek1, J M Njoroge, J L Procter, R W Childs, J Miller.   

Abstract

This study compared flow cytometric analysis with tube agglutination assays for the detection of red blood cell (RBC)-associated complement and immunoglobulins (Igs). RBCs from 20 patients with reactive tube direct antiglobulin tests (DATs) were evaluated by flow cytometry with anti-C3d, anti-IgG, anti-IgM and anti-IgA. Serial samples were also tested from a patient at risk of passenger lymphocyte haemolysis. Results of flow cytometry and tube assays for anti-IgG were as follows: 12 of 20 samples reactive in both; six of 20 nonreactive in both; two of 20 discordant with a reactive tube and a nonreactive flow cytometry assay. Anti-C3d results showed nine of 20 reactive in both and 11 of 20 discordant with a nonreactive tube and a reactive flow cytometry assay. In the IgM flow cytometry assay, three samples were reactive with anti-IgM. Samples from a group A woman who was transplanted with stem cells from a group B donor showed that on days 3 through 6 post-transplant, the flow cytometry assays for anti-IgG and/or anti-C3d were reactive, whilst the tube assays were nonreactive. In conclusion, flow cytometric analysis is more sensitive than the tube assay for the detection of RBC-associated C3d. Further studies are needed to determine the correlation of C3d levels with clinical sequelae.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12581452     DOI: 10.1046/j.1365-3148.2003.00415.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  5 in total

1.  Granulocyte-CSF links destructive inflammation and comorbidities in obstructive lung disease.

Authors:  Evelyn Tsantikos; Maverick Lau; Cassandra Mn Castelino; Mhairi J Maxwell; Samantha L Passey; Michelle J Hansen; Narelle E McGregor; Natalie A Sims; Daniel P Steinfort; Louis B Irving; Gary P Anderson; Margaret L Hibbs
Journal:  J Clin Invest       Date:  2018-04-30       Impact factor: 14.808

2.  Utilisation of Flow-cytometry in the Diagnosis of Auto Immune Haemolytic Anaemia.

Authors:  Jitender Mohan Khunger; H P Pati; M Mahapatra; Arjun Khunger
Journal:  Indian J Hematol Blood Transfus       Date:  2018-10-05       Impact factor: 0.900

3.  Immunohematological and clinical characterizations of mixed autoimmune hemolytic anemia.

Authors:  Sudipta Sekhar Das; Ritam Chakrabarty; R U Zaman
Journal:  Asian J Transfus Sci       Date:  2018 Jul-Dec

4.  A Curious Case of Hemolytic Anemia with Pseudoreticulopenia.

Authors:  Scott Mayer; Nikhilesh Srinivasan; Jenny Nguyen; Ryan Spilman; Dmitriy Scherbak
Journal:  Case Rep Hematol       Date:  2022-04-21

5.  Positive Direct Antiglobulin Test in COVID-19 patients: decision-making process.

Authors:  Julien Cabo; Alice Brochier; Pascale Saussoy; Marie-Astrid van Dievoet; Lena Capirchio; Bénédicte Delire; Véronique Deneys
Journal:  Transfus Clin Biol       Date:  2021-06-07       Impact factor: 1.406

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.