Literature DB >> 12084170

A newly developed gel centrifugation test for quantification of RBC-bound IgG antibodies and their subclasses IgG1 and IgG3: comparison with flow cytometry.

Rainer Lynen1, Olaf Krone, Tobias J Legler, Michael Köhler, Wolfgang R Mayr.   

Abstract

BACKGROUND: Novel gel centrifugation test (GCT) cards were evaluated with respect to their ability to estimate the quantity of IgG on RBCs and the determination of the IgG subclasses IgG1 and IgG3. STUDY DESIGN AND METHODS: In 65 patients with a positive DAT, the amount of IgG-gamma-, IgG1, and IgG3 on RBCs was examined by use of GCT cards and flow cytometry (FC) in parallel. The results were correlated with the presence or absence of hemolysis. In addition, D+ RBCs were studied after sensitization with anti-D sera from 22 alloimmunized pregnant women.
RESULTS: The amount of IgG on the RBCs as determined by GCT dilution cards correlated with FC (r=0.70, p < 0.0001). IgG subclass results as determined by GCT IgG subclass cards were confirmed by FC in 14 cases with an anti-IgG-gamma-chain titer > or =300, whereas IgG subclass cards were not suitable in cases with anti-IgG-gamma-chain titers less than 300. In 44 patients with 2+ or 3+ DAT in the GCT and anti-IgG-gamma-chain titer < or =30, no hemolysis was observed, whereas hemolysis occurred in 13 of 14 patients with an anti-IgG-gamma-chain titer > or =300. GCT data obtained by IATs with anti-D sera were concordant with FC results.
CONCLUSION: There is a correlation between the amount of RBC-bound IgG and immune hemolysis. The GCT cards that detect the anti-IgG-gamma-chain may be useful to predict hemolysis in patients with a 2+ or 3+ DAT in the GCT. The diagnostic value of GCT cards for IgG subclass testing should be investigated further.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12084170     DOI: 10.1046/j.1537-2995.2002.00076.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  3 in total

1.  Utilisation of Flow-cytometry in the Diagnosis of Auto Immune Haemolytic Anaemia.

Authors:  Jitender Mohan Khunger; H P Pati; M Mahapatra; Arjun Khunger
Journal:  Indian J Hematol Blood Transfus       Date:  2018-10-05       Impact factor: 0.900

2.  Autoimmune hemolytic anemia with gel-based immunohematology tests: neural network analysis.

Authors:  Marco Lai; Valerio De Stefano; Raffaele Landolfi
Journal:  Immunol Res       Date:  2014-01       Impact factor: 2.829

Review 3.  Autoimmune hemolytic anemia: From lab to bedside.

Authors:  R K Chaudhary; Sudipta Sekhar Das
Journal:  Asian J Transfus Sci       Date:  2014-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.