Literature DB >> 30970508

Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture.

Lin Tianye1, Yang Peng1, Xu Jingli1, Wei QiuShi1, Zhou GuangQuan1, He Wei1, Zhang Qingwen2.   

Abstract

OBJECTIVE: To compare the bifomechanical advantages and disadvantages of different internal fixation methods for the treatment of Pauwels type III femoral neck fractures.
METHODS: 4 internal fixations were developed to treat Pauwels type III femoral neck fracture finite element models: a: the "F" shaped cannulated screw model, b: the traditional cannulated screw model, c: the "F" shaped cannulated screw coupled with medial plate model, d: the traditional cannulated screw coupled with medial plate. Under the same conditions, the 4 internal fixations and femur of von Mises stress and displacement distribution were studied.
RESULTS: The most significant displacement of all models occurred at the femoral head. The maximum displacement of the femoral heads included: a: 1.53 mm, b: 1.73 mm, c: 1.18 mm and d: 1.34 mm. The von Mises peak stresses of the femoral calcar area in different models were: a: 115.2 MPa, b: 143.5 MPa, c: 107.8 MPa and d: 120.5 MPa. The peak stresses of the four internal fixation models included: a: 318.0 MPa, b: 360.9 MPa, c: 468.8 MPa and d: 771.5 MPa.
CONCLUSION: The "F" shaped cannulated screw technique is capable of eliminating the torsional stress and shear stress while maintaining the axial compressive stress at the fracture end. Besides, the medial support plate can effectively resist the shearing force of the Pauwels III femoral neck fracture and create an excellent mechanical environment for fracture healing. Thus, for the Pauwels III femoral neck fracture, the use of "F" shaped cannulated screws combined with medial plate internal fixation are recommended.
Copyright © 2019 The Authors. Published by Elsevier Masson SAS.. All rights reserved.

Entities:  

Keywords:  Cannulated screw; Femoral neck fracture; Finite element analysis; Internal fixation; Medial plate

Mesh:

Year:  2019        PMID: 30970508     DOI: 10.1016/j.biopha.2019.108658

Source DB:  PubMed          Journal:  Biomed Pharmacother        ISSN: 0753-3322            Impact factor:   6.529


  14 in total

1.  Biplane double supported screw fixation for femoral neck fracture in young adults: A prospective cohort study.

Authors:  Abdus Sami; Rahul Prabhakar; Ajay Kumar Yadav; Vijay Kumar Jain
Journal:  J Orthop       Date:  2022-07-31

2.  The effect of anteromedial support plate with three cannulated screws in the treatment of Pauwels type III femoral neck fracture in young adults.

Authors:  Shanghui Lin; Jinmei Li; Renkai Wang; Yongliang Ou; Zhenyu Jia; Ying Zhang; Hong Xia; Baofeng Li; Bei Chen
Journal:  Eur J Trauma Emerg Surg       Date:  2022-03-15       Impact factor: 2.374

Review 3.  Strategies for managing the destruction of calcar femorale.

Authors:  Jin Mei; Lili Pang; Zhongchao Jiang
Journal:  BMC Musculoskelet Disord       Date:  2021-05-19       Impact factor: 2.362

4.  Finite element modeling of proximal femur with quantifiable weight-bearing area in standing position.

Authors:  Peng Yang; Tian-Ye Lin; Jing-Li Xu; Hui-Yu Zeng; Da Chen; Bing-Lang Xiong; Feng-Xiang Pang; Zhen-Qiu Chen; Wei He; Qiu-Shi Wei; Qing-Wen Zhang
Journal:  J Orthop Surg Res       Date:  2020-09-04       Impact factor: 2.359

5.  Effects of proximal fibular osteotomy on stress changes in mild knee osteoarthritis with varus deformity: a finite element analysis.

Authors:  Deng Pan; Lin TianYe; Yang Peng; Xu JingLi; Li HongZhu; Zhao HeRan; Zhang QingWen; Chen LeiLei; Chen ZhenQiu; Wei QiuShi; He Wei
Journal:  J Orthop Surg Res       Date:  2020-09-03       Impact factor: 2.359

6.  Nonanatomical Reduction of Femoral Neck Fractures in Young Patients (≤65 Years Old) with Internal Fixation Using Three Parallel Cannulated Screws.

Authors:  Guanglei Zhao; Changquan Liu; Kangming Chen; Jinyang Lyu; Jie Chen; Jingsheng Shi; Feiyan Chen; Yibing Wei; Siqun Wang; Jun Xia; Gangyong Huang
Journal:  Biomed Res Int       Date:  2021-01-04       Impact factor: 3.411

7.  Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture.

Authors:  Yue Zhang; Qin Shao; Chensong Yang; Changqing Ai; Di Zhou; Yang Yu; Guixin Sun
Journal:  J Orthop Surg Res       Date:  2021-03-15       Impact factor: 2.359

8.  Migration Measurement of Pins in Postoperative Recovery of the Proximal Femur Fractures Based on 3D Point Cloud Matching.

Authors:  Kaifeng Liu; Kouki Nagamune; Keisuke Oe; Ryosuke Kuroda; Takahiro Niikura
Journal:  Medicina (Kaunas)       Date:  2021-04-22       Impact factor: 2.430

9.  The Effect on the Fracture Healing following Femoral Neck Shortening after Osteoporotic Femoral Neck Fracture Treated with Internal Fixation: Finite Element Analysis.

Authors:  Xiao Yu; Peng-Ze Rong; Qing-Jiang Pang; Xian-Jun Chen; Lin Shi; Cheng-Hao Wang
Journal:  Biomed Res Int       Date:  2021-08-04       Impact factor: 3.411

10.  The role of the medial buttress plate in the treatment of Pauwels type II and III femoral neck fracture in nonelderly patients: a retrospective study and preliminary results.

Authors:  Chao Ma; Yanshi Liu; Jialin Liu; Li Chen; Jinyong Huang; Xuefeng Luo; Zengru Xie
Journal:  BMC Musculoskelet Disord       Date:  2022-01-31       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.