Literature DB >> 30956466

Ultrasound Assessment of Foetal Head-Perineum Distance Prior to Induction of Labour as a Predictor of Successful Vaginal Delivery.

Jijisha Ali1, Shripad Hebbar2.   

Abstract

BACKGROUND: In modern obstetrical practice, incidence of induction of labour is on rise for varied maternal and foetal indications. Ultrasound can help obstetricians in counselling patients before induction of labour and explain the probability of successful induction.
OBJECTIVES: To study the role of foetal head-perineum distance in predicting successful vaginal delivery and to correlate with other parameters such as cervical length and Bishop score.
DESIGN: This study is a prospective case-control study in a tertiary care teaching hospital. POPULATION: There were 250 term patients between 37 and 40+ weeks with singleton cephalic presentation with no contraindications for vaginal delivery.
METHODS: Prior to induction of labour, transperineal ultrasound was performed to measure foetal head-perineum distance. Simultaneously, cervical length was performed using transvaginal ultrasound probe. Bishop score was determined at the same time by clinical examination. MAIN OUTCOME MEASURES: Outcome of induction was considered successful when it resulted in vaginal delivery. It was considered to be a failure if patient did not get into active phase of labour or an operative intervention had to be performed because of non-progress of labour in active phase of labour. Cases were excluded if caesarean delivery had to be performed in the event of foetal distress.
RESULTS: It was observed that as the transperineal foetal head-perineum distance decreased, the rate of vaginal delivery increased. Similarly, when foetal head-perineum distance increased, the rate of caesarean delivery increased. At a cut-off ≤ 5.5 cm, foetal head-perineum distance had a maximum predictability (sensitivity 97%, specificity 88.1%).
CONCLUSION: Transperineal foetal head-distance measured by ultrasound can be used as an important tool to predict vaginal delivery before induction of labour.

Entities:  

Keywords:  Foetal head–perineum distance; Induction of labour; Transperineal ultrasound

Year:  2018        PMID: 30956466      PMCID: PMC6430263          DOI: 10.1007/s13224-018-1120-x

Source DB:  PubMed          Journal:  J Obstet Gynaecol India        ISSN: 0975-6434


  15 in total

1.  Measurement of fetal head descent using the 'angle of progression' on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise.

Authors:  A M Dückelmann; C Bamberg; S A M Michaelis; J Lange; A Nonnenmacher; J W Dudenhausen; K D Kalache
Journal:  Ultrasound Obstet Gynecol       Date:  2010-02       Impact factor: 7.299

2.  Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor.

Authors:  E A Torkildsen; K Å Salvesen; T M Eggebø
Journal:  Ultrasound Obstet Gynecol       Date:  2012-03       Impact factor: 7.299

3.  Prediction of delivery mode with transperineal ultrasound in women with prolonged first stage of labor.

Authors:  E A Torkildsen; K Å Salvesen; T M Eggebø
Journal:  Ultrasound Obstet Gynecol       Date:  2011-05-03       Impact factor: 7.299

4.  Factors associated with successful induction of labor.

Authors:  Ghadeer K Al-Shaikh; Hayfaa A Wahabi; Amel A Fayed; Samia A Esmaeil; Ghada A Al-Malki
Journal:  Saudi Med J       Date:  2012-03       Impact factor: 1.484

5.  Comparison between ultrasound parameters and clinical examination to assess fetal head station in labor.

Authors:  B Tutschek; E A Torkildsen; T M Eggebø
Journal:  Ultrasound Obstet Gynecol       Date:  2013-03-14       Impact factor: 7.299

6.  Cervix assessment for the management of labor induction: reliability of cervical length and Bishop score determined by residents.

Authors:  Raquel Garcia-Simon; Daniel Oros; Daniel Gracia-Cólera; Esther Moreno; Cristina Paules; Silvia Cañizares; Elena Gascón; Ernesto Fabre
Journal:  J Obstet Gynaecol Res       Date:  2014-10-10       Impact factor: 1.730

7.  Sonographic prediction of vaginal delivery in prolonged labor: a two-center study.

Authors:  T M Eggebø; W A Hassan; K Å Salvesen; E Lindtjørn; C C Lees
Journal:  Ultrasound Obstet Gynecol       Date:  2013-12-22       Impact factor: 7.299

8.  Fetal head-symphysis distance: a simple and reliable ultrasound index of fetal head station in labor.

Authors:  A Youssef; E Maroni; A Ragusa; F De Musso; G Salsi; M T Iammarino; A Paccapelo; N Rizzo; G Pilu; T Ghi
Journal:  Ultrasound Obstet Gynecol       Date:  2013-03-06       Impact factor: 7.299

Review 9.  Intrapartum ultrasound: A useful method for evaluating labor progress and predicting operative vaginal delivery.

Authors:  Ki Hoon Ahn; Min-Jeong Oh
Journal:  Obstet Gynecol Sci       Date:  2014-11-20

10.  Patterns and Outcomes of Induction of Labour in Africa and Asia: a secondary analysis of the WHO Global Survey on Maternal and Neonatal Health.

Authors:  Joshua P Vogel; João Paulo Souza; A Metin Gülmezoglu
Journal:  PLoS One       Date:  2013-06-03       Impact factor: 3.240

View more
  1 in total

1.  The effect of maternal intravenous hydration on amniotic fluid index in oligohydramnios.

Authors:  Fatemeh Azarkish; Roksana Janghorban; Shirin Bozorgzadeh; Abedeh Arzani; Rahemeh Balouchi; Mahnaz Didehvar
Journal:  BMC Res Notes       Date:  2022-03-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.