Literature DB >> 25303725

Cervix assessment for the management of labor induction: reliability of cervical length and Bishop score determined by residents.

Raquel Garcia-Simon1, Daniel Oros, Daniel Gracia-Cólera, Esther Moreno, Cristina Paules, Silvia Cañizares, Elena Gascón, Ernesto Fabre.   

Abstract

AIM: To evaluate the reliability of two techniques of cervical ripeness assessment at the beginning of labor induction, as assessed by inexperienced observers.
METHODS: A total of 120 women were prospectively studied at admission for labor induction. Two independent physicians examined consenting women successively but separately. One experienced consultant and one of the six first-year obstetrics residents composed the pairs of observers. The trainees had very limited prior experience with cervical ultrasound scan or evaluating Bishop score. Cervical length and Bishop score were evaluated according to standard methodology. Reliability was described by intraclass correlation coefficients (ICC) and coefficients of variation (COV). Ultrasound cervical length was plotted according to the Bland-Altman method.
RESULTS: The median Bishop score and mean cervical length were similar for all observers. Ultrasound cervical length and Bishop score were highly reliable when evaluated by first-year residents. Ultrasound cervical length showed the highest interobserver agreement, with ICC values over 0.9 and COV values of approximately 10% or less for all trainees. The Bishop score was also reliable, but with lower ICC and higher COV values.
CONCLUSION: Bishop score and ultrasound cervical length examination for the management of labor induction are accurate and easy to learn by inexperienced first-year residents. However, cervical length showed higher reliability than the Bishop score.
© 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

Entities:  

Keywords:  Bishop score; cervical length; cervix assessment; interobserver reliability; labor induction; training

Mesh:

Year:  2014        PMID: 25303725     DOI: 10.1111/jog.12553

Source DB:  PubMed          Journal:  J Obstet Gynaecol Res        ISSN: 1341-8076            Impact factor:   1.730


  1 in total

1.  Ultrasound Assessment of Foetal Head-Perineum Distance Prior to Induction of Labour as a Predictor of Successful Vaginal Delivery.

Authors:  Jijisha Ali; Shripad Hebbar
Journal:  J Obstet Gynaecol India       Date:  2018-04-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.