The dislocating hip arthroplasty: prevention and treatment.

Preetesh D Patel1, Aaron Potts, Mark I Froimson.   

Abstract

The dislocating hip is functionally impairing and leads to patient dissatisfaction. The etiology is multifactorial and may include component malpositioning, soft tissue laxity, and component or anatomical impingement. Initial treatment of dislocation usually consists of closed reduction followed by the use of an abduction pillow or brace or a knee immobilizer, although evidence to support these actions is limited. Operative intervention is generally reserved for patients with more than 2 dislocations and should aim to correct the cause of dislocation using a simple algorithm. Proper component positioning is key to prevention of further dislocation, but other tools include modular implants, jumbo heads, and increased offset. Finally, constrained acetabular components may be considered if a patient fails one of the above surgical options.

Entities:  

Mesh:

Year:  2007        PMID: 17570285     DOI: 10.1016/j.arth.2006.12.111

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  54 in total

1.  [Diagnostics and therapy of luxation after total hip arthroplasty].

Authors:  B Preininger; F Haschke; C Perka
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

2.  Dislocation after total hip arthroplasty.

Authors:  A Zahar; A Rastogi; D Kendoff
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

3.  What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

Authors:  Matthew P Abdel; Philipp von Roth; Matthew T Jennings; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

4.  Are abductor muscle quality and previous revision surgery predictors of constrained liner failure in hip arthroplasty?

Authors:  Michael G Zywiel; Loi'y H Mustafa; Peter M Bonutti; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-20       Impact factor: 3.075

5.  CORR Insights®: Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Ola Rolfson
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

Review 6.  [Hip dislocation after revision arthroplasty : Risk assessment and treatment strategies].

Authors:  P M Prodinger; J Schauwecker; H Mühlhofer; N Harrasser; F Pohlig; C Suren; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 7.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

8.  Cause of irreducible dislocation of a re-revision THR.

Authors:  Evelyn Patricia Murphy; Christopher Fenelon; Shane Russell; Finbarr Condon
Journal:  BMJ Case Rep       Date:  2018-06-04

9.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

10.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717