Literature DB >> 30892255

Multi-Sensor Fusion Approach for Cuff-Less Blood Pressure Measurement.

Fen Miao, Zeng-Ding Liu, Ji-Kui Liu, Bo Wen, Qing-Yun He, Ye Li.   

Abstract

Ambulatory blood pressure (BP) provides valuable information for cardiovascular risk assessment. The present cuff-based devices are intrusive for long-term BP monitoring, whereas cuff-less BP measurement methods based on pulse transit time or multi-parameter are inferior in robustness and reliability by using electrocardiogram (ECG) and photoplethysmogram signals. This study examined a multi-sensor fusion-based platform and algorithm for systolic BP (SBP), mean arterial pressure (MAP), and diastolic BP (DBP) estimation. The proposed multi-sensor platform was comprised of one ECG sensor and two pulse pressure wave sensors for simultaneous signal collection. After extracting 35 features from the collected signals, a weakly supervised feature selection method was proposed for dimension reduction because the reference oscillometric technique-based BP are intermittent and can be redeemed as coarse-grained labels. BP models were then established using a multi-instance regression algorithm. A total of 85 participants including 17 hypertensive and 12 hypotensive patients were enrolled. Experimental results showed that the proposed approach exhibited good accuracy for diverse population with an estimation error of 1.62 ± 7.76 mmHg for SBP, 1.53 ± 6.03 mmHg for MAP, and 1.49 ± 5.52 for DBP, which complied with the association for the advancement of medical instrumentation standards in BP estimation. Moreover, the estimation accuracy is with random daily fluctuations rather than long-term degradation through a maximum two-month follow-up period indicated good robustness performance. These results suggest that the proposed approach is with high reliability and robustness and thus provides a novel insight for cuff-less BP measurement.

Entities:  

Mesh:

Year:  2019        PMID: 30892255     DOI: 10.1109/JBHI.2019.2901724

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  17 in total

1.  Cuffless Blood Pressure Monitoring from an Array of Wrist Bio-Impedance Sensors Using Subject-Specific Regression Models: Proof of Concept.

Authors:  Bassem Ibrahim; Roozbeh Jafari
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-10       Impact factor: 3.833

2.  Cuffless Blood Pressure Monitoring: Promises and Challenges.

Authors:  Jay A Pandit; Enrique Lores; Daniel Batlle
Journal:  Clin J Am Soc Nephrol       Date:  2020-07-17       Impact factor: 8.237

Review 3.  Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals.

Authors:  Ramakrishna Mukkamala; Mohammad Yavarimanesh; Keerthana Natarajan; Jin-Oh Hahn; Konstantinos G Kyriakoulis; Alberto P Avolio; George S Stergiou
Journal:  Hypertension       Date:  2021-09-13       Impact factor: 10.190

4.  Continuous Blood Pressure Estimation From Electrocardiogram and Photoplethysmogram During Arrhythmias.

Authors:  ZengDing Liu; Bin Zhou; Ye Li; Min Tang; Fen Miao
Journal:  Front Physiol       Date:  2020-09-09       Impact factor: 4.566

5.  A Survey of Challenges and Opportunities in Sensing and Analytics for Risk Factors of Cardiovascular Disorders.

Authors:  Nathan C Hurley; Erica S Spatz; Harlan M Krumholz; Roozbeh Jafari; Bobak J Mortazavi
Journal:  ACM Trans Comput Healthc       Date:  2020-12-30

6.  Estimating Surgical Blood Loss Volume Using Continuously Monitored Vital Signs.

Authors:  Yang Chen; Chengcheng Hong; Michael R Pinsky; Ting Ma; Gilles Clermont
Journal:  Sensors (Basel)       Date:  2020-11-17       Impact factor: 3.576

7.  COVID-19 and Non-COVID-19 Classification using Multi-layers Fusion From Lung Ultrasound Images.

Authors:  Ghulam Muhammad; M Shamim Hossain
Journal:  Inf Fusion       Date:  2021-02-25       Impact factor: 12.975

8.  Cuffless blood pressure monitoring from a wristband with calibration-free algorithms for sensing location based on bio-impedance sensor array and autoencoder.

Authors:  Bassem Ibrahim; Roozbeh Jafari
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

9.  A Novel Clustering-Based Algorithm for Continuous and Noninvasive Cuff-Less Blood Pressure Estimation.

Authors:  Ali Farki; Reza Baradaran Kazemzadeh; Elham Akhondzadeh Noughabi
Journal:  J Healthc Eng       Date:  2022-01-15       Impact factor: 2.682

10.  Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement.

Authors:  Ting-Wei Wang; Jhen-Yang Syu; Hsiao-Wei Chu; Yen-Ling Sung; Lin Chou; Endian Escott; Olivia Escott; Ting-Tse Lin; Shien-Fong Lin
Journal:  Biosensors (Basel)       Date:  2022-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.