Literature DB >> 30874826

[MRI-Interactions with magnetically active and electrically conductive material].

F Schick1.   

Abstract

BACKGROUND: Patients undergoing MRI examinations are exposed to a strong static magnetic field and powerful electromagnetic alternating fields. Undesired or even dangerous effects could be caused if implants or objects with magnetic or electrically conductive elements are accidentally brought into the examination area.
METHODS: Relevant interactions in MRI between magnetic/electric fields and body tissue as well as foreign materials are systematically presented, based on proven physical principles. RESULTS OF PRACTICAL RELEVANCE: Natural components of the human body are mainly diamagnetic leading to only hardly perceptible magnetic forces in MRI. In contrast, ferromagnetic items as iron show translational forces of more than hundred times their weight force when brought to the entry of the bore. Lengthy ferromagnetic items are additionally subjected to torque. Materials with high electrical conductivity as metals and carbon fibre-reinforced plastic are also safety relevant. Especially long conductive structures as often present in implants are prone to induced strong electrical currents and high voltages at their end portions. Maximum voltages occurring at the implants and current density in adjacent tissue which might cause significant heating are hardly predictable for individual cases. Implants providing extended conductive loops for ring currents often show strong vibrations due to gradient switching. Counter forces must be considered when tilting conductive plates or ring structures inside the magnetic field area.

Entities:  

Keywords:  Metals; Radio frequency; Safety; Static magnetic field; Tissue burning

Mesh:

Substances:

Year:  2019        PMID: 30874826     DOI: 10.1007/s00117-019-0514-9

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  11 in total

1.  Investigating the magnetic susceptibility properties of fresh human blood for noninvasive oxygen saturation quantification.

Authors:  Varsha Jain; Osheiza Abdulmalik; Kathleen Joy Propert; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

Review 2.  [Physical interactions in MRI: Some rules of thumb for their reduction].

Authors:  M Mühlenweg; G Schaefers; S Trattnig
Journal:  Radiologe       Date:  2015-08       Impact factor: 0.635

Review 3.  Magnetic resonance imaging measurement of iron overload.

Authors:  John C Wood
Journal:  Curr Opin Hematol       Date:  2007-05       Impact factor: 3.284

4.  Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone.

Authors:  J A Hopkins; F W Wehrli
Journal:  Magn Reson Med       Date:  1997-04       Impact factor: 4.668

Review 5.  The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds.

Authors:  J F Schenck
Journal:  Med Phys       Date:  1996-06       Impact factor: 4.071

6.  [MR implant labelling and its use in clinical MRI practice].

Authors:  M Mühlenweg; G Schaefers
Journal:  Radiologe       Date:  2015-08       Impact factor: 0.635

7.  Lanthanide-based susceptibility contrast agents: assessment of the magnetic properties.

Authors:  S Fossheim; C Johansson; A K Fahlvik; D Grace; J Klaveness
Journal:  Magn Reson Med       Date:  1996-02       Impact factor: 4.668

8.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model.

Authors:  S Ogawa; R S Menon; D W Tank; S G Kim; H Merkle; J M Ellermann; K Ugurbil
Journal:  Biophys J       Date:  1993-03       Impact factor: 4.033

9.  Radio frequency versus susceptibility effects of small conductive implants--a systematic MRI study on aneurysm clips at 1.5 and 3 T.

Authors:  Ulrike A Lauer; Hansjorg Graf; Alexander Berger; Claus D Claussen; Fritz Schick
Journal:  Magn Reson Imaging       Date:  2005-05       Impact factor: 2.546

Review 10.  Biological effects and safety in magnetic resonance imaging: a review.

Authors:  Valentina Hartwig; Giulio Giovannetti; Nicola Vanello; Massimo Lombardi; Luigi Landini; Silvana Simi
Journal:  Int J Environ Res Public Health       Date:  2009-06-10       Impact factor: 3.390

View more
  2 in total

Review 1.  [Safety of implants in high field and ultrahigh field MRI].

Authors:  O Kraff; H H Quick
Journal:  Radiologe       Date:  2019-10       Impact factor: 0.635

Review 2.  [Safe MRI examinations in patients with pacemakers and ICD].

Authors:  D Beitzke
Journal:  Radiologe       Date:  2019-10       Impact factor: 0.635

  2 in total