Literature DB >> 10231893

Effect of elution modes on protein separation by cross-axis coil planet centrifuge with two different types of coiled columns.

K Shinomiya1, Y Kabasawa, Y Ito.   

Abstract

Effect of elution modes on protein separation was investigated using cross-axis coil planet centrifuge (cross-axis CPC) with two different types of coiled columns, i.e., eccentric coil and toroidal coil assemblies. Myoglobin and lysozyme were separated with an aqueous two-phase solvent system composed of 12.5% (w/w) polyethylene glycol 1000 and 12.5% (w/w) dibasic potassium phosphate. The substantial effect of elution modes was observed by the toroidal coil, while the negative result was given at the eccentric coil. Using the toroidal coil, higher peak resolution of proteins was attained at the tail to head elution mode. In the outward lower phase mobile elution mode, the satisfactory separation was obtained by both eccentric coil and toroidal coil assemblies. However, in the inward upper phase mobile elution mode, the toroidal coil produced a broad and asymmetric myoglobin peak. The analysis using polyacrylamide gel electrophoresis revealed that the toroidal coil partially separated the components originally present in the myoglobin sample. As the result, a modified equation was devised to express the peak resolution (Rs) using the lysozyme peak. The overall results indicated that the toroidal coil produced better partition efficiency than the eccentric coil under the optimized experimental condition including the direction of the Coriolis force acting on the mobile phase in the toroidal coil.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10231893     DOI: 10.1080/10826069908544886

Source DB:  PubMed          Journal:  Prep Biochem Biotechnol        ISSN: 1082-6068            Impact factor:   2.162


  5 in total

1.  Improved Separations of Proteins and Sugar Derivatives Using the Small-Scale Cross-Axis Coil Planet Centrifuge with Locular Multilayer Coiled Columns.

Authors:  Kazufusa Shinomiya; Motoki Umezawa; Manami Seki; Jun Nitta; Kazumasa Zaima; Naoki Harikai; Yoichiro Ito
Journal:  Separations       Date:  2016-09-22

2.  Partition Efficiency of High-Pitch Locular Multilayer Coil for Countercurrent Chromatographic Separation of Proteins Using Small-Scale Cross-Axis Coil Planet Centrifuge and Application to Purification of Various Collagenases with Aqueous-Aqueous Polymer Phase Systems.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Norio Inokuchi; Kazuya Nakagomi; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2011-01       Impact factor: 1.312

3.  Partition efficiencies of three different coiled columns for the coil satellite centrifuge at higher rotation speed combinations.

Authors:  Kazufusa Shinomiya; Kazumasa Zaima; Miho Yasue; Rika Honda; Yoshiyuki Sakuma; Naoki Harikai; Koji Tokura; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2019-03-06       Impact factor: 4.759

4.  PARTITION EFFICIENCY OF NEWLY DESIGNED LOCULAR MULTILAYER COIL FOR COUNTERCURRENT CHROMATOGRAPHIC SEPARATION OF PROTEINS USING SMALL-SCALE CROSS-AXIS COIL PLANET CENTRIFUGE WITH AQUEOUS-AQUEOUS POLYMER PHASE SYSTEMS.

Authors:  Kazufusa Shinomiya; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2009-01-01       Impact factor: 1.312

5.  Toroidal coil chromatography: the effect of scale-up and "g" field on stage efficiency.

Authors:  Ian Sutherland; Peter Hewitson; Joost de Folter
Journal:  J Chromatogr A       Date:  2010-12-28       Impact factor: 4.759

  5 in total