Literature DB >> 8255192

Time of flight quantification of coronary flow with echo-planar MRI.

B P Poncelet1, R M Weisskoff, V J Wedeen, T J Brady, H Kantor.   

Abstract

Detection and quantification of flow of the left anterior descending (LAD) coronary artery in healthy volunteers are demonstrated using echo-planar imaging (EPI). A time-of-flight (TOF) model was used to derive coronary flow velocities from wash-in curves, free of cardiac wall motion contamination. Short-axis cardiac studies were performed using a gated, gradient echo EPI technique to limit the effect of cardiac wall motion on coronary vessel imaging. A series of 10 to 20 single or multislice images were acquired within a single breath-hold. Real-time cine series showed the LAD coronary artery with a detectability of 91% (n = 23) and revealed beat-to-beat variability in vessel position of a magnitude equal to or greater than its diameter. Flow velocity was measured in the proximal portion of the artery at rest and during exercise. The data demonstrated the known phasic pattern of LAD flow: Vsystole < or = 5 cm/s and peak Vdiastole = 14 +/- 3 cm/s (n = 11, V = mean laminar flow velocity). During isometric exercise, a LAD flow velocity increase (52 +/- 24%) was detected in eight of nine subjects. The capacity of the EPI TOF method to detect flow velocity changes should prove clinically useful for future assessment of coronary flow reserve.

Entities:  

Mesh:

Year:  1993        PMID: 8255192     DOI: 10.1002/mrm.1910300407

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Early, Complete Infarct Vessel Patency: Arriving at a Gold Standard for Future Clinical Investigation in Myocardial Reperfusion.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1997       Impact factor: 2.300

2.  MR-based coronary artery blood velocity measurements in patients without coronary artery disease.

Authors:  M Schiemann; F Bakhtiary; V Hietschold; A Koch; A Esmaeili; H Ackermann; A Moritz; T J Vogl; N D Abolmaali
Journal:  Eur Radiol       Date:  2006-01-13       Impact factor: 5.315

Review 3.  Ultra-high-speed MR imaging.

Authors:  C P Davis; G C McKinnon; J F Debatin; G K von Schulthess
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

4.  Flow Dynamics in the Aortic Arch and Its Effect on the Arterial Input Function in Cardiac Computed Tomography.

Authors:  Parastou Eslami; Jung-Hee Seo; Albert C Lardo; Marcus Y Chen; Rajat Mittal
Journal:  J Biomech Eng       Date:  2019-03-06       Impact factor: 2.097

Review 5.  Magnetic resonance imaging in the evaluation of non-ischemic cardiomyopathies: current applications and future perspectives.

Authors:  Ilan Gottlieb; Robson Macedo; David A Bluemke; João A C Lima
Journal:  Heart Fail Rev       Date:  2006-12       Impact factor: 4.214

6.  Assessment of coronary blood flow in humans using phase difference MR imaging. Comparison with intracoronary Doppler flow measurement.

Authors:  W Kessler; W Moshage; A Galland; D Zink; S Achenbach; W Nitz; G Laub; K Bachmann
Journal:  Int J Card Imaging       Date:  1998-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.