Raihan Khamal1, Zaleha Md Isa1, Rosnah Sutan1, Nor Mohd Razif Noraini2, Hasanain Faisal Ghazi3.
Abstract
INTRODUCTION: Indoor air quality in day care centers (DCCs) is an emerging research topic nowadays. Indoor air pollutants such as particulate matter (PM) and microbes have been linked to respiratory health effects in children, particularly asthma-related symptoms such as night coughs and wheezing due to early exposure to indoor air contaminants.Entities:
Mesh:
Substances:
Year: 2019 PMID: 30741516 PMCID: PMC6997519 DOI: 10.5334/aogh.2425
Source DB: PubMed Journal: Ann Glob Health ISSN: 2214-9996 Impact factor: 2.462
Figure 1Location of Seremban District, Negeri Sembilan. (Adapted from Shamsuddin and Yaakup [14]).
Sociodemographic Characteristics of Respondents and Wheezing Symptoms (n = 90).
| Variables | f (%) or mean (SD) | Wheezing Symptom | |||
|---|---|---|---|---|---|
| Yes (n = 17) f (%) or Mean (SD) | No (n = 73) f (%) or Mean (SD) | ||||
| Age* | 1.54 (0.51) | 1.35 (0.50) | 1.59 (0.49) | 1.772 | 0.080 |
| Sex | |||||
| Male | 50 (55.6) | 12 (24.0) | 38 (76.0) | 1.918 | 0.166 |
| Female | 40 (44.4) | 5 (12.5) | 35 (87.5) | ||
| Birth weight (kg)† | 3.05 (0.39) | 3.04 (0.39) | 3.05 (0.40) | 0.146 | 0.884 |
| Breastfeeding | |||||
| Yes | 86 (45.6) | 16 (18.6) | 70 (81.4) | 0.102 | 0.749 |
| No | 4 (4.4) | 1 (25.0) | 3 (75.0) | ||
| Duration of breastfeeding | |||||
| Less than 6 mo. | 33 (36.7) | 4 (12.1) | 29 (87.9) | 1.558 | 0.212 |
| 6 mo. and above | 57 (63.3) | 13 (22.8) | 44 (77.2) | ||
| Food allergy | |||||
| Yes | 10 (11.1) | 4 (40.0) | 6 (60.0) | 3.273 | 0.070 |
| No | 80 (88.9) | 13 (16.3) | 67 (83.8) | ||
| ETS exposure at home | |||||
| Yes | 50 (55.6) | 9 (18.0) | 41 (82.0) | 0.058 | 0.810 |
| No | 40 (44.4) | 8 (20.0) | 32 (80.0) | ||
| Age entering DCC | |||||
| Less than 1 y | 34 (37.8) | 10 (29.4) | 24 (70.6) | 6.852 | 0.037† |
| 1–2 y | 29 (32.2) | 6 (20.7) | 23 (79.3) | ||
| More than 2 y | 27 (30.0) | 1 (3.7) | 26 (96.3) | ||
| Duration of stay in DCC | |||||
| More than 3 y | 8 (8.9) | 1 (12.5) | 7 (87.5) | 4.565 | 0.012† |
| 1–3 y | 48 (53.3) | 13 (27.1) | 35 (72.9) | ||
| Less than 1 y | 34 (37.8) | 3 (8.8) | 31 (91.2) | ||
| Household income | |||||
| Low income | 18 (20.0) | 2 (11.1) | 16 (88.9) | 21.194 | <0.001† |
| Middle income | 67 (74.4) | 14 (20.9) | 53 (70.1) | ||
| High income | 5 (5.6) | 1 (20.0) | 4 (80.0) | ||
| Parent’s level of education | |||||
| High education | 64 (71.1) | 0 (0) | 26 (100.0) | 8.515 | 0.004† |
| Low education | 26 (28.9) | 17 (26.6) | 47 (73.4) | ||
| Family history of asthma | |||||
| Yes | 19 (21.1) | 4 (21.1) | 15 (78.9) | 0.074 | 0.786 |
| No | 71 (78.9) | 13 (18.3) | 58 (81.7) | ||
| Type of housing | |||||
| Detached house | 9 (10.0) | 0 (0) | 9 (100.0) | 2.373 | 0.305 |
| Terraced | 77 (85.6) | 16 (20.8) | 61 (79.2) | ||
| Apartments/condominium/flats | 4 (4.4) | 1 (25.0) | 3 (75.0) | ||
| Residence near major roadway | |||||
| Yes | 40 (44.4) | 5 (12.5) | 35 (87.5) | 1.918 | 0.166 |
| No | 50 (55.6) | 12 (24.0) | 38 (76.0) | ||
| Pets at home | |||||
| Yes | 19 (21.1) | 3 (15.8) | 16 (84.2) | 0.151 | 0.698 |
| No | 71 (78.9) | 14 (19.7) | 57 (80.3) | ||
| Carpets at home | |||||
| Yes | 44 (48.9) | 10 (22.7) | 34 (77.3) | 0.828 | 0.363 |
| No | 46 (51.1) | 7 (15.2) | 39 (84.8) | ||
DCC = day care center; ETS = environmental tobacco smoke; SD = standard deviation.
*Mean (SD).
† Significant level at P value < 0.05.
Sampling Sites and Environmental Conditions of 10 Air-Conditioned DCCs in Seremban District, Negeri Sembilan.
| DCC | Building Age (y) | Number of Occupants (2014/2015) | Type of Building | Location | Site | Temp (°C) Mean (SD) | R.H. (%) Mean (SD) | |
|---|---|---|---|---|---|---|---|---|
| A | 25+ | 16 | Private residential | Urban | Playroom | 28.40 (0.1) | 71.12 (0.4) | |
| B | 15+ | 20 | Private residential | Urban | *Near roadway | Playroom | 28.58 (0.2) | 65.63 (0.8) |
| C | 10+ | 14 | Private residential | Urban | *Near industrial area (<1 km) | Playroom | 31.18 (0.1) | 59.60 (0.5) |
| D | 25+ | 32 | Public residential | Urban | Playroom | 28.81 (0.3) | 67.00 (0.3) | |
| E | 25+ | 28 | Public residential | Urban | Playroom | 28.58 (0.2) | 72.78 (0.7) | |
| F | 5+ | 25 | Private residential | Urban | Playroom | 30.67 (0.1) | 74.30 (0.4) | |
| G | 10+ | 10 | Private residential | Urban | Playroom | 28.10 (0.2) | 69.8 (0.5) | |
| H | 10+ | 30 | Private residential | Urban | *Near construction site | Playroom | 27.30 (0.4) | 67.10 (0.4) |
| I | 5+ | 19 | Commercial building | Urban | *Near roadway | Playroom | 27.17 (0.2) | 79.00 (0.7) |
| J | 10+ | 17 | Private residential | Urban | *Near roadway | Playroom | 27.54 (0.1) | 78.00 (0.6) |
DCC = day care center; R.H. = relative humidity; SD = standard deviation; Temp = temperature.
*Indicates that center near to pollution source.
Prevalence of Health Symptoms and Severity of Symptoms Among Respondents in 10 DCCs (n = 90).
| DCC, N = 90 | Wheezing Only, n (%) | Night Cough Only, n (%) | Both Symptoms (Wheezing and Night Cough), n (%) | Wake up from Sleep, n (%) | Nebulizer Treatment, n (%) | Admit to Ward, n (%) | Doctor Diagnosed Risk of Asthma, n (%) |
|---|---|---|---|---|---|---|---|
| A | 3 (50.0) | 5 (83.3) | 2 (33.3) | 3 (50.0) | 2 (33.3) | 0 (0) | 1 (16.7) |
| B | 12 (78.6) | 5 (35.7) | 5 (35.7) | 9 (64.3) | 5 (35.7) | 1 (7.1) | 3 (21.4) |
| C | 4 (57.1) | 7 (100.0) | 4 (57.1) | 6 (85.7) | 3 (42.9) | 2 (28.6) | 2 (28.6) |
| D | 1 (16.7) | 4 (66.7) | 1 (16.7) | 0 (0) | 1 (16.7) | 1 (16.7) | 1 (16.7) |
| E | 7 (100.0) | 4 (57.1) | 0 (0) | 2 (28.6) | 0 (0) | 0 (0) | 1 (14.3) |
| F | 11 (100.0) | 7 (63.6) | 0 (0) | 1 (9.1) | 0 (0) | 0 (0) | 1 (9.1) |
| G | 4 (100.0) | 2 (50.0) | 0 (0) | 2 (50.0) | 1 (25.0) | 1 (25.0) | 1 (25.0) |
| H | 1 (6.7) | 10 (66.7) | 1 (6.7) | 4 (26.7) | 0 (0) | 0 (0) | 1 (6.7) |
| I | 1 (10.0) | 2 (20.0) | 1 (10.0) | 1 (10.0) | 1 (10.0) | 1 (10.0) | 1 (10.0) |
| J | 2 (20.0) | 6 (60.0) | 1 (10.0) | 3 (30.0) | 2 (20.0) | 1 (10.0) | 3 (30.0) |
DCC = day care center.
Sampling Point and Number of Air Samples of the Investigated DCCs.
| Sampling Points | No. of Rooms | No. of Air Samples for PM2.5 and PM10 Level | No. of Air Samples for Microbial Count (TBC and TFC) |
|---|---|---|---|
| Playroom | 10 | 10 | 60 |
| Bedroom | 10 | 10 | 60 |
| Outdoor (outside the building) | – | 10 | 40 |
DCC = day care center; No. = number; PM = particulate matter; TBC = total bacterial count; TFC = total fungus count.
Mean and Standard Deviation of IAQ Parameters from the Investigated DCCs.
| Rooms/Area | PM2.5 Level (μg/m3) | PM10 Level (μg/m3) | TBC (CFU/m3) | TFC (CFU/m3) |
|---|---|---|---|---|
| Playroom | ||||
| Mean ± SD | 69.35 ± 47.61 | 81.11 ± 45.29 | 566.63 ± 359.03 | 643.25 ± 312.09 |
| Min–Max | 17–170 | 28–144 | 155–1310 | 268–1182 |
| Bedroom | ||||
| Mean ± SD | 113.21 ± 103.52 | 79.91 ± 46.42 | 754.80 ± 326.22 | 699.68 ± 385.61 |
| Min–Max | 30–430 | 30–170 | 229–1279 | 269–1489 |
| Outdoor | ||||
| Mean ± SD | 70.11 ± 49.23 | 79.61 ± 43.69 | 204.21 ± 123.11 | 568.42 ± 313.17 |
| Min–Max | 39–540 | 29–350 | 178–980 | 200–560 |
DCC = day care center; IAQ = indoor air quality; ICOP = Indoor Air Quality Code of Practice; NAAQ = National Ambient Air Quality; PM = particulate matter; SD = standard deviation; TBC = total bacterial count; TFC = total fungus count.
Mean Concentrations of Indoor Air Quality Parameters at 10 Air-Conditioned DCCs Investigated in the District of Seremban, Negeri Sembilan.
| DCC | Carbon Dioxide (ppm)* | PM2.5 (μg/m3)† | PM10 (μg/m3)* | Airborne Bacteria (CFU/m3)* | Airborne Fungi (CFU/m3)* |
|---|---|---|---|---|---|
| A | 578.38 | 170.00‡ | 133.00 | 1310‡ | 514 |
| B | 669.25 | 134.00‡ | 144.00 | 751‡ | 1182‡ |
| C | 527.50 | 17.00 | 29.00 | 579‡ | 268 |
| D | 474.00 | 25.00 | 28.60 | 401 | 1161‡ |
| E | 519.78 | 98.00‡ | 99.80 | 221 | 662 |
| F | 480.89 | 80.00‡ | 130.00 | 155 | 460 |
| G | 848.00 | 68.00‡ | 72.00 | 894‡ | 549 |
| H | 1322.00‡ | 47.00‡ | 67.00 | 401 | 634 |
| I | 427.38 | 21.40 | 34.00 | 231 | 534 |
| J | 621.86 | 32.00 | 35.00 | 1100‡ | 268 |
CFU = colony-forming unit; DCC = day care center; PM = particulate matter.
* ICOP [17].
† NAAQ [18].
‡ Exceeded the acceptable level.
Figure 2Comparison of PM2.5 and PM10 levels in each of the DCCs investigated. Abbreviations: CFU = colony-forming unit; DCC = day care center; PM = particulate matter.
Figure 3Comparison of TBC levels in each of the DCCs investigated. Abbreviations: CFU = colony-forming unit; DCC = day care center; TBC = total bacterial count.
Figure 4Comparison of TFC levels in each of the DCCs investigated. Abbreviations: CFU = colony-forming unit; DCC = day care center; TFC = total fungus count.
Association Between IAQ Parameters and Wheezing Symptom Among Respondents in 10 DCCs Investigated.
| IAQ Parameters | Wheezing Symptom | df | 95%CI | ||||
|---|---|---|---|---|---|---|---|
| Yes (n = 17) | No (n = 73) | Upper | Lower | ||||
| Carbon dioxide (ppm) | 626.97 (193.96) | 703.57 (320.17) | 0.945 | 88 | 0.347 | –84.52 | 237.71 |
| Particulate matter 2.5 (μgm3) | 82.67 (64.61) | 66.25 (42.68) | –1.285 | 88 | 0.020† | –41.71 | –0.39 |
| Particulate matter 10 (μgm3) | 84.38 (54.75) | 80.35 (43.21) | –0.329 | 88 | 0.743 | –28.40 | 20.32 |
| Total bacterial count (CFU/m3) | 778.65 (335.63) | 517.26 (348.17) | –2.806 | 88 | 0.006† | –446.51 | –76.25 |
| Total fungal count (CFU/m3) | 670.05 (404.31) | 637.01 (290.38) | –0.391 | 88 | 0.697 | –201.18 | 135.10 |
CFU = colony-forming unit; CI = confidence interval; DCC = day care center; df = degrees of freedom; IAQ = indoor air quality; SD = standard deviation.
* Student’s t test.
† P < 0.05 is significant.
Factors Associated with Wheezing Symptoms Among Toddlers in Day Care Centers in the District of Seremban.
| Variables | Simple Logistic Regression | Multiple Logistic Regression* | ||||
|---|---|---|---|---|---|---|
| Regression Coefficient (b) | Crude OR | Regression Coefficient (b) | Adjusted OR | |||
| Age | –0.966 | 0.381 | 0.085 | |||
| Sex | ||||||
| Male | 0.793 | 2.211 | 0.173 | |||
| Female | 1.00 | |||||
| Birth weight (kg) | –0.103 | 0.902 | 0.883 | |||
| Breastfeeding | ||||||
| Yes | 1.00 | |||||
| No | 0.377 | 1.458 | 0.749 | |||
| Duration of breastfeeding | ||||||
| Less than 6 mo | –0.762 | 0.467 | 0.219 | |||
| 6 mo and greater | 1.00 | |||||
| Food allergy | ||||||
| Yes | –1.234 | 0.291 | 0.083 | |||
| No | 1.00 | |||||
| ETS exposure at home | ||||||
| Yes | 0.130 | 1.139 | 0.810 | |||
| No | 1.00 | |||||
| Age enter DCC | ||||||
| Less than 1 y | 1.914 | 6.783 | 0.087 | |||
| 1–2 y | 2.383 | 10.833 | 0.037† | |||
| More than 2 y | 1.00 | |||||
| Duration of stay in DCC | ||||||
| More than 3 y | –0.389 | 1.677 | 0.015† | |||
| 1–3 y | 0.956 | 2.600 | 0.392 | |||
| Less than 1 y | 1.00 | |||||
| Household income | ||||||
| Low income | –0.693 | 0.500 | 0.607 | |||
| Middle income | 0.055 | 1.057 | <0.001† | |||
| High income | 1.00 | |||||
| Parent’s level of education | ||||||
| High education | 1.00 | |||||
| Low education | –20.186 | 2.890 | 0.004† | –56.090 | 1.790 | 0.035† |
| Family history of asthma | ||||||
| Yes | –0.174 | 0.841 | 0.786 | –2.439 | 1.087 | 0.040† |
| No | 1.00 | |||||
| Type of housing | ||||||
| Detached house | –20.104 | 0.051 | 0.380 | |||
| Terraced | –0.240 | 0.787 | 0.840 | |||
| Apartment/condominium/flat | 1.00 | |||||
| Residence near major roadway | ||||||
| Yes | 0.793 | 2.211 | 0.173 | |||
| No | 1.00 | |||||
| Pets at home | ||||||
| Yes | 0.270 | 1.310 | 0.698 | |||
| No | 1.00 | |||||
| Carpets at home | ||||||
| Yes | 0.494 | 1.639 | 0.366 | |||
| No | 1.00 | |||||
| DCC Status | ||||||
| Acceptable | 1.00 | |||||
| Not acceptable | –1.153 | 2.316 | 0.040† | 2.004 | 7.417 | 0.032† |
Multicollinearity and interaction term was checked and not found. Hosmer-Lemeshow test, (P = 0.300). Classification table (overly correctly classified percentage = (69.3%). Ngelkerke R2 = 0.28.
DCC = day care center; ETS = environmental tobacco smoke; LR = logistic regression; OR = odds ratio.
* Forward LR multiple logistic regression model was applied.
† Significant level at p < 0.05.