Literature DB >> 30712164

Identification of residual-recurrent cholesteatoma in operated ears: diagnostic accuracy of dual-energy CT and MRI.

Giovanni Foti1, Alberto Beltramello2, Giorgio Minerva3, Matteo Catania4, Massimo Guerriero5, Sergio Albanese3, Giovanni Carbognin2.   

Abstract

PURPOSE: The aim of this study was to compare the diagnostic accuracy of magnetic resonance imaging (MRI) and dual-energy computed tomography (DECT) to identify residual-recurrent cholesteatoma using the second-look surgery as the reference standard.
METHODS: This prospective, institutional review board-approved study included 19 consecutive patients (11 males and 8 females; mean age of 62.2, range 34-80 years). Since five patients were studied bilaterally, a total of 24 ears were evaluated with DECT and MRI between February 2017 and June 2018. Any abnormal middle ear attenuation on high-resolution CT images (HRCT) or DECT color-coded maps, and any abnormal signal on MRI images was evaluated by four experienced radiologists. Diagnostic accuracy values of HRCT, DECT maps and CT numbers (by using receiver operator curves) and MRI were compared. Interobserver and intraobserver agreement were calculated.
RESULTS: Residual-recurrent cholesteatoma was diagnosed at surgery in 16/24 ears (66.6%). MRI and DECT revealed a total of 15/16 and 14/16 cholesteatomas, respectively. The sensitivity, specificity, PPV and NPV and accuracy of MRI and DECT were 93.7, 87.5, 93.7, 87.5, and 91.6% and 87.5, 87.5, 93.3, 87.5 and 87.5%, respectively. CT numbers were significantly different between positive (mean 57.6 HU, range - 65, 112 HU) and negative cases (mean 5.4 HU, range - 100, 66 HU) with p < 0.001. The interobserver and intraobserver agreement were k = 0.87 and k = 0.83, respectively.
CONCLUSION: DECT may provide an accurate demonstration of residual-recurrent middle ear cholesteatoma.

Entities:  

Keywords:  Cholesteatoma; Diffusion-weighted images; Dual-energy CT; Magnetic resonance imaging; Recurrence

Mesh:

Year:  2019        PMID: 30712164     DOI: 10.1007/s11547-019-00997-y

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  28 in total

1.  CT scanning in "second look" combined approach tympanoplasty.

Authors:  S P Blaney; P Tierney; M Oyarazabal; D A Bowdler
Journal:  Rev Laryngol Otol Rhinol (Bord)       Date:  2000

Review 2.  Basic principles of diffusion-weighted imaging.

Authors:  Roland Bammer
Journal:  Eur J Radiol       Date:  2003-03       Impact factor: 3.528

Review 3.  Imaging of the postoperative middle ear.

Authors:  Marc T Williams; Denis Ayache
Journal:  Eur Radiol       Date:  2004-01-29       Impact factor: 5.315

4.  Material differentiation by dual energy CT: initial experience.

Authors:  Thorsten R C Johnson; Bernhard Krauss; Martin Sedlmair; Michael Grasruck; Herbert Bruder; Dominik Morhard; Christian Fink; Sabine Weckbach; Miriam Lenhard; Bernhard Schmidt; Thomas Flohr; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-12-07       Impact factor: 5.315

5.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

6.  Quantitative MR evaluation of intracranial epidermoid tumors by fast fluid-attenuated inversion recovery imaging and echo-planar diffusion-weighted imaging.

Authors:  S Chen; F Ikawa; K Kurisu; K Arita; J Takaba; Y Kanou
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

7.  The diagnostic accuracy of non-echo-planar diffusion-weighted imaging in the detection of residual and/or recurrent cholesteatoma of the temporal bone.

Authors:  M H G Dremmen; P A M Hofman; J R Hof; R J Stokroos; A A Postma
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-22       Impact factor: 3.825

Review 8.  Dual-energy CT revisited with multidetector CT: review of principles and clinical applications.

Authors:  Muşturay Karçaaltıncaba; Aykut Aktaş
Journal:  Diagn Interv Radiol       Date:  2010-11-14       Impact factor: 2.630

9.  Imaging of non-operated cholesteatoma: clinical practice guidelines.

Authors:  D Ayache; V Darrouzet; F Dubrulle; C Vincent; S Bobin; M Williams; C Martin
Journal:  Eur Ann Otorhinolaryngol Head Neck Dis       Date:  2012-02-07       Impact factor: 2.080

10.  Diffusion-weighted MR imaging of cholesteatoma in pediatric and adult patients who have undergone middle ear surgery.

Authors:  P Aikele; T Kittner; C Offergeld; H Kaftan; K-B Hüttenbrink; M Laniado
Journal:  AJR Am J Roentgenol       Date:  2003-07       Impact factor: 3.959

View more
  2 in total

1.  High-resolution computed tomography (HRCT) in pediatric and adult patients with unsafe chronic suppurative otitis media (CSOM) and its surgical correlation.

Authors:  Ramandeep Singh; Rubal Rai; Paramdeep Singh; Sanjay Sethi; Amrit Pal Singh Ahluwalia; Gagandeep Choudhary
Journal:  J Family Med Prim Care       Date:  2020-08-25

2.  Comparison of Readout-Segmented Echo-Planar Imaging and Single-Shot TSE DWI for Cholesteatoma Diagnostics.

Authors:  M Wiesmueller; W Wuest; M S May; S Ellmann; R Heiss; M Saake; R Janka; M Uder; F B Laun
Journal:  AJNR Am J Neuroradiol       Date:  2021-04-29       Impact factor: 4.966

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.