Literature DB >> 30711395

Effectiveness of posterior structures in the development of proximal junctional kyphosis following posterior instrumentation: A biomechanical study in a sheep spine model.

Murat Korkmaz1, Turgut Akgul2, Kerim Sariyilmaz3, Okan Ozkunt4, Fatih Dikici3, Onder Yazicioglu2.   

Abstract

INTRODUCTION: Proximal junctional kyphosis - PJK has been defined by a 10 or greater increase in kyphosis at the proximal junction as measured by the Cobb angle from the caudal endplate of the uppermost instrumented vertebrae (UIV) to the cephalad endplate of the vertebrae 1 segments cranial to the UIV. In this biomechanical study, it is aimed to evaluate effects of interspinosus ligament complex distruption and facet joint degeneration on PJK development.
MATERIALS AND METHODS: Posterior instrumentation applied between T2 - T7 vertebrae using pedicle screws to randomly selected 21 sheeps, divided into 3 groups. First group selected as control group (CG), of which posterior soft tissue and facet joints are protected. In second group (spinosus group, SG) interspinosus ligament complex which 1 segment cranial to UIV has been transected, and third group (faset group-FG) was applied facet joint excision. 25 N, 50 N, 100 N, 150 N and 200 N forces applied at frequency of 5 Hertz as 100 cycles axial to the samples. Then, 250 N, 275 N and 300 N forces applied static axially. Interspinosus distance, kyphosis angle and discus heights was measured in radiological evaluation. Abnormal PJK was defined by a proximal junctional angle greater than 100 and at least 100 greater than the corresponding preoperative measurement.
RESULTS: In CG group, average interspinosus distance was 6,6 ± 1.54 mm and kyphosis angle was 2,2 ± 0.46° before biomechanical testing, and they were measured as 9,4 ± 1.21 mm and 3,3 ±0.44° respectively after forces applied to samples. In SG group, average interspinosus distance was 6,2 ± 1.72 mm and kyphosis angle was 2,7 ± 1.01° before experiment, and they were measured as 20,8 ± 5.66 mm and 15,1 ± 2.34° respectively after forces applied to samples. In FG group, average interspinosus distance was 4,8 ± 1.15 mm and kyphosis angle was -1 ± 4.14° before experiment, and they were measured as 11,1 ±1.96mm and 11 ± 2.87° respectively after forces applied to samples. In comparison to group CG, statistically significant junctional kyphosis was seen on both FG and SG group after statistical analysis. (p < 0.05). PJK was seen statistically significant more on SG group than FG group. (p < 0.05). Not any statistically significant difference was seen on measurement of disk distances among three groups. (p > 0.05)
CONCLUSIONS: Protecting interspinosus ligament complex and facet joint unity during posterior surgical treatment for spine deformation is vital to prevent PJK development. Based on our literature review, this is the first biomechanical study that reveals interspinosus ligament complex are more effective on preventing PJK development than facet joints.
Copyright © 2019 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Adolescent idiopathic scoliosis; Biomechanic; Junctional disorders; PJK; Proximal junctional kyphosis; Scheuermann kyphosis

Mesh:

Year:  2019        PMID: 30711395      PMCID: PMC6819779          DOI: 10.1016/j.aott.2019.01.003

Source DB:  PubMed          Journal:  Acta Orthop Traumatol Turc        ISSN: 1017-995X            Impact factor:   1.511


Introduction

With the improvements in surgical techniques and instruments, severe sagittal and coronal deformities of the spine could be successfully corrected. Nonetheless, adjacent segment pathologies secondary to overcorrection and rigid fixation, also known as proximal junctional kyphosis (PJK), has emerged as a frequent surgical problem,1, 2, 3 with a reported incidence of 5,8%–59%.4, 5, 6 Although the literature is conflicting regarding the definition of PJK, the most commonly accepted definition is an angling of more than 10° between the instrumented level and the next vertebra.7, 8 PJK results from the stress secondary to rigid instrumentation that is placed in the flexible transition zone of the spine. Although many risk factors have been attributed to PJK development, rigid posterior instrumentation, excessive soft tissue damage, overcorrection in the sagittal plane, and advanced age are the most commonly identified etiologies.5, 9, 10 Furthermore, the facet joint injury and damage to paravertebral muscles and ligaments in the transition zone are among the most commonly cited causes of PJK.11, 12 Although several biomechanical and cadaveric studies13, 14 investigating the impacts of soft tissue injury on PJK development are available in the literature, to the best of our knowledge, studies have not yet been conducted to compare the facet joint integrity with posterior ligament protection in terms of their roles in PJK development to date. The present study aimed to biomechanically evaluate the integrity of supraspinous and interspinous ligaments and facet joints on PJK development in a sheep spine.

Materials and methods

The current study was carried out on 21 skeletally mature sheep spines (over 6 years of age) which included the vertebrae from C7 to T8, intervertebral discs, posterior elements, end-plates and all posterior ligaments. The fresh frozen spine models were kept at −20° Celsius throughout the whole study. Before performing the biomechanical testing, each spine was thawed with physiologic serum at room temperature. In the preparation of specimens, initially, the supraspinous and interspinous ligaments and facet joints were identified and preserved. The costovertebral joints were protected at all levels, and the distal joint of the ribs was excised at a distance of 2 cm. A total of 10 titanium pedicle screws (5 cm* 25 mm) were inserted using an image intensifier at the 5 vertebral levels between the T2 and T7 vertebrae. After that, posterior instrumentation was completed using two 6 × 460 mm titanium rods which countered as nearly physiologically kyphotic in an attempt to mimic the physiological thoracic kyphosis of 25°. Finally, all models were confirmed radiologically (Fig. 1). After above initial preparations, all the sheep spines were divided into 3 groups of 7 spines each: control group (CG), ligament group (LG), and facet group (FG).
Fig. 1

All spines were instrumented with pedicle screws at the 5 vertebral levels between the T2 and T7 vertebrae. Anterior-posterior and lateral radiography view of the spine.

All spines were instrumented with pedicle screws at the 5 vertebral levels between the T2 and T7 vertebrae. Anterior-posterior and lateral radiography view of the spine. The control group included spines in which the facet joint and inter- and supraspinous structures were protected. The ligament group involved spines in which the facet joint was protected but the inter- and supraspinous structures were completely resected. Finally, the facet group was composed of spines in which the facet joint alone was resected at one level proximal to the upper instrumented vertebra.

Biomechanical experiment

For the biomechanical experiment, the spine specimens were subjected to axial loading with a MTS acumen electrodynamic biomechanical test device. The specimens were then fixed proximally and distally with K wires and 15 gram polyester putty (steel putty) mixed with a catalyzer (Dibenzoil peroxide), in order to obtain biomechanical loading in an erect position similar to that observed in humans. After confirming the stiffness of the spine models, 100 cycles of forces of 25 N, 50 N, 100 N, 150 N and 200 N at a frequency of 5 Hertz were, respectively, performed axially. Following the cyclical loading, 250 N, 275 N and 300 N forces were, respectively, performed statically in the axial direction (Fig. 2).
Fig. 2

Instrumented spines were fixed proximally and distally with K wires and polyester putty (steel putty) and axially loaded with MTS acumen electrodynamic biomechanical test device.

Instrumented spines were fixed proximally and distally with K wires and polyester putty (steel putty) and axially loaded with MTS acumen electrodynamic biomechanical test device. After the biomechanical testing, direct radiography and computerized tomography of the spine models were obtained, and all were radiologically analyzed and compared before and after the biomechanical experiment by an orthopedic surgeon who specialized in the spinal column and a radiologist who specialized in the musculoskeletal system. The evaluation criteria included: the distance between the spinous processes of the upper instrumented and adjacent vertebrae before and after axial loading, the kyphosis angle, the anterior and posterior disc height (Fig. 3).
Fig. 3

All groups were radiologically evaluated included the distance between the spinous processes of the upper instrumented and adjacent vertebrae before and after axial loading, the kyphosis angle, and the anterior and posterior disk height.

All groups were radiologically evaluated included the distance between the spinous processes of the upper instrumented and adjacent vertebrae before and after axial loading, the kyphosis angle, and the anterior and posterior disk height. All statistical analyses were performed using the SPSS 18.0.0 statistical package (SPSS, Inc., Chicago, IL, USA), and p value of less than 0.05 was accepted as significant. The Kolmogorov–Smirnov and Shapiro–Wilk tests were used to evaluate the normality of the data distribution. Differences between groups were tested for significance using the Kruskal–Wallis test, and paired groups were evaluated using the Mann–Whitney U test.

Results

The interspinous distance that was measured radiologically from elevated from 6,6+/−1,55 mm before the biomechanical loading to 9,4+/−12,1 mm after the biomechanical loading in the CG (p > 0,05), from 6,2+/−1,7 mm to 20,8+/−5,7 mm in the LG (p < 0,05), and 4,8+/−1,1 mm to 11,1+/−2 mm in the FG (p < 0,05). The statistical analyses showed that the interspinous distance increased significantly following biomechanical loading in the LG and FG compared with the CG (p < 0,05). Furthermore, the increase in the interspinosus distance was greater for the LG when compared to the FG (Table 1).
Table 1

Statistically significantly junctional kyphosis development was detected on both FG and SG group than control group (p < 0.05). PJK was seen significantly more frequently on SG group than FG group (p < 0.05).

Interspinous distance (mm)
Local kyphosis angle (degree)
Discus height (mm)
BeforeAfterBeforeAfterAnterior discus height -BeforeAnterior discus height -AfterPosterior discus height -BeforePosterior discus height -After
Control group (CG)6,69,42,23,34,23,33,33,9
Spinous group (SG)6,220,82,715,14,13,32,84,7
Facet group (FG)4,811,11,011,04,22,72,94,1
Statistically significantly junctional kyphosis development was detected on both FG and SG group than control group (p < 0.05). PJK was seen significantly more frequently on SG group than FG group (p < 0.05). The interspinous distance that was measured manually raised from 7,5+/−0,5 mm before the biomechanical loading to 11,5+/−0,5 mm after the loading in the CG (p > 0,05), from 7,5+/−0,5 mm to 20,2+/−6,5 mm in the LG (p < 0,05), and 5,6+/−1,1 mm to 17,3+/−1,4 mm in the FG (p < 0,05). These increases were statistically greater in the LG compared to the FG (p < 0,05). The local kyphosis angle raised from 2,5+/−0,2 before the axial loading to 3,3+/−0,44 after the loading in the CG, from 2,7+/−1,1 to 15,1+/−2,3 in the LG, and −0,9+/−4,1 to 11+/−2,9 in the FG (p < 0,05). The statistical analyses revealed that the increases in local junctional kyphosis angle in the LG and FG were significantly greater compared with the CG (p < 0,05). Also, the increase in the LG was greater than in the FG (p < 0,05). In cycle 28 of 200 N loading, insufficiency developed in the proximal junction of one of the samples from the ligament group and resulted in dislocation. The anterior disk height dropped from 4,19+/−0,27 mm before the biomechanical testing to 3+/−0,5 mm after the biomechanical testing (p < 0,0001), although the posterior disk height increased from 3,15+/−0,5 mm to 4,25+/−0,6 mm (p < 0,0001). In terms of disk height, no statistically significant difference was observed among three groups (p > 0,05).

Discussion

Although posterior instrumentation and fusion procedure has been widely recognized as the choice of treatment method for the correction of spinal deformities with favorable outcomes, the development of proximal junctional kyphosis has emerged as a serious problem in the orthopedic practice. According to the several studies many potential factors were described such as long rigid instrumentations, dissection of the paravertebral muscles, in the vertebrae adjacent to the instrumented vertebra secondary to rigid systems. Despite these several reports describe the potential risk factors of PJK, there is no consensus yet. In our biomechanical study the effect of posterior ligament complex and facet joint integrity were examined. Many researchers viewed the risk factors of PJK. Lee reported that a kyphosis of 5° or more at one level proximal to the upper instrumented vertebra prior to surgery could lead to the development of postoperative junctional kyphosis. Lowe and Kasten thought that the prevalence of PJK to be as high as 50% of patients who underwent spinal deformity correction.17, 18 In a finite element study Cammarata et al concluded that the development of deformity might be related to sagittal balance, the implant type used in the proximal vertebra, and posterior soft tissue damage or the loss of joint unity. Posterior ligamentous complex consist of ligamentum flavum, facet joints and interspinous and supraspinous ligaments. Integrity of these strong structure plays a major role to prevent PJK. During posterior instrumentation and fusion surgery, PJK can develop as a secondary trauma to the posterior ligamentous complex. Also, in a biomechanical study which effects of posterior elements were evaluated on human cadavers, effects of posterior elements on stability were evaluated. When posterior soft tissue and ligaments were fully excised, a 44.72% loss in stability was recorded. In these respect, we resected the facet joints and inter- and supraspinous ligaments at one level proximal to the upper instrumented vertebra in two groups. To detect the effects of facet joints and inter- and supraspinous ligaments on PJK, these groups were compared separetaly and compared with the control group. To the best of our knowledge, only few studies have been designed to investigate the role of facet joint and posterior soft tissue in the development of PJK. Anatomically cervico-thoracic spine allows a transition zone because of flexible and lordotic cervical spine and rigid and kyphotic thoracic spine. As we know that PJK results from enhanced stress concentration after posterior spinal surgery because of transition zone at the junction. Also increasing of stiffness after long instrumentation enhances the risk of PJK at proximal of the instrumentation. However at the cervico-thoracic junction pedicles smaller and locate more medially and inter- and supraspinous ligaments weaker than lumbar spine. Because of this anatomic features the risk of disruption of the posterior ligamentous complex more than lower spinal regions. In addition, since an increased risk of PJK due to the use of implant combinations with pedicle screws has been reported, we examined implantation using a pedicle screw rod combination and thoracic stabilization. In a finite element study which set out to determine the risk factors of PJK, Cammarata et al concluded that the development of deformity might be related to sagittal balance, the implant type used in the proximal vertebra, and posterior soft tissue damage or the loss of joint unity. Their findings also supported the fact that if the level of upper instrumented vertebra was between T1 and T3, there was an increased risk for PJK development. Therefore, we evaluated the possibility of junctional kyphosis development between T1 and T2 by performing long segment pedicle screw instrumentation in our spine model. After the biomechanical testing interspinosus distance, kyphosis angle and discus heights was measured in radiological evaluation. Our data showed that interspinous distance increased from 5,9+/−1,6 mm to 13,8+/−6,2 mm and the kyphosis angle increased from 1,43+/−2,9 to 9,8+/−5,4 (p < 0,0001) from before to after biomechanical loading. Statistically, these changes were higher in the ligament group than in all other groups, and they were higher in the facet group than in the control group (p < 0,05). While our study suggests that facet joint and ligament injury can both lead to PJK development, the supraspinous and interspinous ligaments are the main structures that prevent PJK development, while the facet joint plays an auxiliary role. Clinical studies have pinpointed many factors that influence PJK development. In our study, although the control group was more stable than the ligament or facet groups, it still experienced statistically significant kyphosis changes with loading. A trend toward kyphosis development was observed in the control group in terms of changes in interspinous distance (6,6+/−1,55 mm to 9,4+/−12,1 mm), kyphosis angle (2,5+/−0,2 to 3,3+/−0,44) and disk height (anterior disk height from 4,2+/−0,2 mm to 3,3+/−0,65 mm) (p < 0,05). This may be interpreted as a result of biomechanical loading or surgery alone in the biomechanical evaluation of cadavers that do not have the ability to rejuvenate. However, injury of supraspinous and interspinous ligaments significantly increased the likelihood kyphosis changes. In our study, similar to previous studies in the literature, we found that the posterior structures of the facet joint and interspinous and supraspinous ligaments contributed significantly to stability. Based on our literature review, this is the first biomechanical study that reveals interspinosus ligament complex are more effective on preventing PJK development than facet joints. Finally, limitation of the study was due to the nature of the animal model chosen. Experimental biomechanical studies can be conducted on cadavers or animal models. Also, animal models can have anatomical and biomechanical differences from human spine. Human cadaver bones represent a better in vivo environment than animal models and provide an erect spine which has advantageous as biomechanical features. Also, it's difficult to obtain and expensive. As sheep and human spines are similar, particularly in the thoracic and lumbar regions, sheep spine models may be used in place of human spine models.20, 21

Conclusion

Rigid and long segment posterior instrumentation and fusion surgery can be considered to be a risk factor for PJK development. The protection of the inter-and supraspinous ligaments can provide solid stability. Furthermore, the integrity of facet joints can contribute an additional stability. Therefore, protection of the interspinous and supraspinous ligaments as well as facet joints is important in preventing PJK.
  20 in total

1.  The effect of spinal instrumentation on kinematics at the cervicothoracic junction: emphasis on soft-tissue response in an in vitro human cadaveric model.

Authors:  Ryan M Kretzer; Nianbin Hu; Hidemasa Umekoji; Daniel M Sciubba; George I Jallo; Paul C McAfee; P Justin Tortolani; Bryan W Cunningham
Journal:  J Neurosurg Spine       Date:  2010-10

2.  Biomechanical testing of three newly developed transpedicular multisegmental fixation systems.

Authors:  S Eggli; F Schläpfer; M Angst; P Witschger; M Aebi
Journal:  Eur Spine J       Date:  1992-09       Impact factor: 3.134

3.  New universal instrumentation in spinal surgery.

Authors:  Y Cotrel; J Dubousset; M Guillaumat
Journal:  Clin Orthop Relat Res       Date:  1988-02       Impact factor: 4.176

4.  Incidence, risk factors and classification of proximal junctional kyphosis: surgical outcomes review of adult idiopathic scoliosis.

Authors:  Mitsuru Yagi; King B Akilah; Oheneba Boachie-Adjei
Journal:  Spine (Phila Pa 1976)       Date:  2011-01-01       Impact factor: 3.468

5.  Anatomy of the sheep spine and its comparison to the human spine.

Authors:  H J Wilke; A Kettler; K H Wenger; L E Claes
Journal:  Anat Rec       Date:  1997-04

6.  Proximal junctional kyphosis in adult spinal deformity following long instrumented posterior spinal fusion: incidence, outcomes, and risk factor analysis.

Authors:  R Chris Glattes; Keith H Bridwell; Lawrence G Lenke; Yongjung J Kim; Anthony Rinella; Charles Edwards
Journal:  Spine (Phila Pa 1976)       Date:  2005-07-15       Impact factor: 3.468

Review 7.  Junctional spinal disorders in operated adult spinal deformities: present understanding and future perspectives.

Authors:  V Arlet; M Aebi
Journal:  Eur Spine J       Date:  2013-02-06       Impact factor: 3.134

8.  An analysis of sagittal curves and balance after Cotrel-Dubousset instrumentation for kyphosis secondary to Scheuermann's disease. A review of 32 patients.

Authors:  T G Lowe; M D Kasten
Journal:  Spine (Phila Pa 1976)       Date:  1994-08-01       Impact factor: 3.468

9.  Incidence, mode, and location of acute proximal junctional failures after surgical treatment of adult spinal deformity.

Authors:  Richard Hostin; Ian McCarthy; Michael OʼBrien; Shay Bess; Breton Line; Oheneba Boachie-Adjei; Doug Burton; Munish Gupta; Christopher Ames; Vedat Deviren; Khaled Kebaish; Christopher Shaffrey; Kirkham Wood; Robert Hart
Journal:  Spine (Phila Pa 1976)       Date:  2013-05-20       Impact factor: 3.468

10.  The effect of posterior thoracic spine anatomical structures on motion segment flexion stiffness.

Authors:  Andy L Anderson; Terence E McIff; Marc A Asher; Douglas C Burton; R Christopher Glattes
Journal:  Spine (Phila Pa 1976)       Date:  2009-03-01       Impact factor: 3.468

View more
  2 in total

1.  Bone Fusion Morphology after Circumferential Minimally Invasive Spine Surgery Using Lateral Lumbar Interbody Fusion and Percutaneous Pedicle Screws without Bone Grafting in the Thoracic Spine: A Retrospective Study.

Authors:  Masayuki Ishihara; Shinichirou Taniguchi; Koki Kawashima; Takashi Adachi; Masaaki Paku; Yoichi Tani; Muneharu Ando; Takanori Saito
Journal:  Medicina (Kaunas)       Date:  2022-03-30       Impact factor: 2.948

2.  Conditions for Achieving Postoperative Pelvic Incidence-Lumbar Lordosis &lt; 10° in Circumferential Minimally Invasive Surgery for Adult Spinal Deformity.

Authors:  Masayuki Ishihara; Shinichirou Taniguchi; Takashi Adachi; Yoichi Tani; Masaaki Paku; Muneharu Ando; Takanori Saito
Journal:  J Clin Med       Date:  2022-03-13       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.