Anouk M Barendregt1,2, E Charlotte van Gulik3,4, Paul F C Groot3, Koert M Dolman5,6,7, J Merlijn van den Berg4, Amara Nassar-Sheikh Rashid4, Dieneke Schonenberg-Meinema4, Cristina Lavini3, Karen Rosendahl8,9, Robert Hemke3, Taco W Kuijpers4, Mario Maas3, Charlotte M Nusman3,4. 1. Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands. a.m.barendregt@amc.uva.nl. 2. Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands. a.m.barendregt@amc.uva.nl. 3. Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105, AZ, Amsterdam, The Netherlands. 4. Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands. 5. Department of Pediatric Rheumatology, Reade, Dr. Jan van Breemenstraat 2, Amsterdam, the Netherlands. 6. Department of Pediatric Rheumatology, Onze Lieve Vrouwe Gasthuis West, Jan Tooropstraat, 164, Amsterdam, the Netherlands. 7. Department of Pediatric Rheumatology, Onze Lieve Vrouwe Gasthuis Oost, Oosterpark 9, Amsterdam, the Netherlands. 8. Section of Pediatric Radiology, Haukeland University Hospital, Jonas Lies Vei 65, PB 1400, 5021, Bergen, Norway. 9. Department of Clinical Medicine, K1, University of Bergen, Jonas Lies Vei 87, N-5021, Bergen, Norway.
Abstract
BACKGROUND: Post-contrast synovial thickness measurement is necessary for scoring disease activity in juvenile idiopathic arthritis (JIA). However, the timing of post-contrast sequences varies widely among institutions. This variation in timing could influence thickness measurements. OBJECTIVE: To measure thickness of the synovial membrane on early and late post-contrast knee magnetic resonance (MR) images of patients with JIA. MATERIALS AND METHODS: Dynamic contrast-enhanced T1-weighted knee MR images of 53 children with JIA with current or past knee arthritis were used to study synovial thickness at time point 1 (about 1 min) and time point 2 (about 5 min after contrast administration). Two experienced readers, who were blinded for the time point, independently measured synovial thickness at a predefined, marked location in the patellofemoral compartment on randomized images. Synovial thickness at the two time points was compared using the Wilcoxon signed rank test. Repeatibility of the synovial thickness measurements was studied using intraclass correlation coefficients and Bland-Altman plots. RESULTS: Median synovial thickness of the 53 patients (median age: 13.5 years, 59% female) increased with prolonged post-contrast interval with a synovial thickness of 1.4 mm at time point 1 and a synovial thickness of 1.5 mm at time point 2 (P<0.001). Repeated synovial thickness measurements showed an intraclass correlation coefficient (ICC) of 0.75, P<0.05 for time point 1 and an ICC of 0.91, P<0.05 for time point 2. CONCLUSION: Post-contrast synovial membrane thickness measurements are time-dependent. Therefore, standardization of post-contrast image acquisition timing is important to achieve consistent grading of synovial inflammation.
BACKGROUND: Post-contrast synovial thickness measurement is necessary for scoring disease activity in juvenile idiopathic arthritis (JIA). However, the timing of post-contrast sequences varies widely among institutions. This variation in timing could influence thickness measurements. OBJECTIVE: To measure thickness of the synovial membrane on early and late post-contrast knee magnetic resonance (MR) images of patients with JIA. MATERIALS AND METHODS: Dynamic contrast-enhanced T1-weighted knee MR images of 53 children with JIA with current or past knee arthritis were used to study synovial thickness at time point 1 (about 1 min) and time point 2 (about 5 min after contrast administration). Two experienced readers, who were blinded for the time point, independently measured synovial thickness at a predefined, marked location in the patellofemoral compartment on randomized images. Synovial thickness at the two time points was compared using the Wilcoxon signed rank test. Repeatibility of the synovial thickness measurements was studied using intraclass correlation coefficients and Bland-Altman plots. RESULTS: Median synovial thickness of the 53 patients (median age: 13.5 years, 59% female) increased with prolonged post-contrast interval with a synovial thickness of 1.4 mm at time point 1 and a synovial thickness of 1.5 mm at time point 2 (P<0.001). Repeated synovial thickness measurements showed an intraclass correlation coefficient (ICC) of 0.75, P<0.05 for time point 1 and an ICC of 0.91, P<0.05 for time point 2. CONCLUSION: Post-contrast synovial membrane thickness measurements are time-dependent. Therefore, standardization of post-contrast image acquisition timing is important to achieve consistent grading of synovial inflammation.
Authors: Paul A Yushkevich; Joseph Piven; Heather Cody Hazlett; Rachel Gimpel Smith; Sean Ho; James C Gee; Guido Gerig Journal: Neuroimage Date: 2006-03-20 Impact factor: 6.556
Authors: Jasper F M M Rieter; Laura Tanturri de Horatio; Charlotte M Nusman; Lil-Sofie Ording Müller; Robert Hemke; Derk F M Avenarius; Marion A J van Rossum; Clara Malattia; Mario Maas; Karen Rosendahl Journal: Pediatr Radiol Date: 2016-07-12
Authors: Carl Orr; Elsa Vieira-Sousa; David L Boyle; Maya H Buch; Christopher D Buckley; Juan D Cañete; Anca I Catrina; Ernest H S Choy; Paul Emery; Ursula Fearon; Andrew Filer; Danielle Gerlag; Frances Humby; John D Isaacs; Søren A Just; Bernard R Lauwerys; Benoit Le Goff; Antonio Manzo; Trudy McGarry; Iain B McInnes; Aurélie Najm; Constantino Pitzalis; Arthur Pratt; Malcolm Smith; Paul P Tak; Rogier Thurlings; João E Fonseca; Douglas J Veale; Sander W Tas Journal: Nat Rev Rheumatol Date: 2017-07-13 Impact factor: 20.543
Authors: Alexander Y Hui; William J McCarty; Koichi Masuda; Gary S Firestein; Robert L Sah Journal: Wiley Interdiscip Rev Syst Biol Med Date: 2011-08-08
Authors: Mikkel Østergaard; Charles Peterfy; Philip Conaghan; Fiona McQueen; Paul Bird; Bo Ejbjerg; Ron Shnier; Philip O'Connor; Mette Klarlund; Paul Emery; Harry Genant; Marissa Lassere; John Edmonds Journal: J Rheumatol Date: 2003-06 Impact factor: 4.666
Authors: Robert Hemke; Taco W Kuijpers; J Merlijn van den Berg; Mira van Veenendaal; Koert M Dolman; Marion A J van Rossum; Mario Maas Journal: Eur Radiol Date: 2013-02-01 Impact factor: 5.315
Authors: Laura Tanturri de Horatio; Susan C Shelmerdine; Paola d'Angelo; Pier Luigi Di Paolo; Silvia Magni-Manzoni; Clara Malattia; Maria Beatrice Damasio; Paolo Tomà; Derk Avenarius; Karen Rosendahl Journal: Pediatr Radiol Date: 2022-09-23
Authors: Jeffrey M A van der Krogt; F Verkuil; E Charlotte van Gulik; Robert Hemke; J Merlijn van den Berg; Dieneke Schonenberg-Meinema; Angelika Kindermann; Koert M Dolman; Marc A Benninga; Taco W Kuijpers; Mario Maas; Charlotte M Nusman Journal: Rheumatol Int Date: 2021-11-22 Impact factor: 3.580
Authors: Floris Verkuil; E Charlotte van Gulik; Charlotte M Nusman; Anouk M Barendregt; Amara Nassar-Sheikh Rashid; Dieneke Schonenberg-Meinema; Koert M Dolman; Mario Maas; Taco W Kuijpers; J Merlijn van den Berg; Robert Hemke Journal: Pediatr Radiol Date: 2020-07-13
Authors: Robert Hemke; Nele Herregods; Jacob L Jaremko; Gunnar Åström; Derk Avenarius; Fabio Becce; Dennis K Bielecki; Mikael Boesen; Danoob Dalili; Chiara Giraudo; Kay-Geert Hermann; Paul Humphries; Amanda Isaac; Anne Grethe Jurik; Andrea S Klauser; Ola Kvist; Frederiek Laloo; Mario Maas; Adam Mester; Edwin Oei; Amaka C Offiah; Patrick Omoumi; Olympia Papakonstantinou; Athena Plagou; Susan Shelmerdine; Paolo Simoni; Iwona Sudoł-Szopińska; Laura Tanturri de Horatio; James Teh; Lennart Jans; Karen Rosendahl Journal: Eur Radiol Date: 2020-05-12 Impact factor: 5.315