Literature DB >> 30682536

Multi-vendor standardized sequence for edited magnetic resonance spectroscopy.

Muhammad G Saleh1, Daniel Rimbault2, Mark Mikkelsen3, Georg Oeltzschner3, Anna M Wang3, Dengrong Jiang4, Ali Alhamud5, Jamie Near6, Michael Schär7, Ralph Noeske8, James B Murdoch9, Lars Ersland10, Alexander R Craven11, Gerard Eric Dwyer11, Eli Renate Grüner12, Li Pan13, Sinyeob Ahn13, Richard A E Edden3.   

Abstract

Spectral editing allows direct measurement of low-concentration metabolites, such as GABA, glutathione (GSH) and lactate (Lac), relevant for understanding brain (patho)physiology. The most widely used spectral editing technique is MEGA-PRESS, which has been diversely implemented across research sites and vendors, resulting in variations in the final resolved edited signal. In this paper, we describe an effort to develop a new universal MEGA-PRESS sequence with HERMES functionality for the major MR vendor platforms with standardized RF pulse shapes, durations, amplitudes and timings. New RF pulses were generated for the universal sequence. Phantom experiments were conducted on Philips, Siemens, GE and Canon 3 T MRI scanners using 32-channel head coils. In vivo experiments were performed on the same six subjects on Philips and Siemens scanners, and on two additional subjects, one on GE and one on Canon scanners. On each platform, edited MRS experiments were conducted with the vendor-native and universal MEGA-PRESS sequences for GABA (TE = 68 ms) and Lac editing (TE = 140 ms). Additionally, HERMES for GABA and GSH was performed using the universal sequence at TE = 80 ms. The universal sequence improves inter-vendor similarity of GABA-edited and Lac-edited MEGA-PRESS spectra. The universal HERMES sequence yields both GABA- and GSH-edited spectra with negligible levels of crosstalk on all four platforms, and with strong agreement among vendors for both edited spectra. In vivo GABA+/Cr, Lac/Cr and GSH/Cr ratios showed relatively low variation between scanners using the universal sequence. In conclusion, phantom and in vivo experiments demonstrate successful implementation of the universal sequence across all four major vendors, allowing editing of several metabolites across a range of TEs.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Edited MRS; HERMES; MEGA-PRESS; Magnetic resonance spectroscopy; Standardization

Mesh:

Substances:

Year:  2019        PMID: 30682536      PMCID: PMC7008948          DOI: 10.1016/j.neuroimage.2019.01.056

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  36 in total

1.  Motor cortex glutathione deficit in ALS measured in vivo with the J-editing technique.

Authors:  N Weiduschat; X Mao; J Hupf; N Armstrong; G Kang; D J Lange; H Mitsumoto; D C Shungu
Journal:  Neurosci Lett       Date:  2014-04-24       Impact factor: 3.046

2.  Edited MRS is sensitive to changes in lactate concentration during inspiratory hypoxia.

Authors:  Richard A E Edden; Ashley D Harris; Kevin Murphy; C John Evans; Neeraj Saxena; Judith E Hall; Damian M Bailey; Richard G Wise
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

3.  Reproducibility of macromolecule suppressed GABA measurement using motion and shim navigated MEGA-SPECIAL with LCModel, jMRUI and GANNET.

Authors:  Muhammad G Saleh; Jamie Near; Alqadafi Alhamud; Frances Robertson; André J W van der Kouwe; Ernesta M Meintjes
Journal:  MAGMA       Date:  2016-07-08       Impact factor: 2.310

4.  WET, a T1- and B1-insensitive water-suppression method for in vivo localized 1H NMR spectroscopy.

Authors:  R J Ogg; P B Kingsley; J S Taylor
Journal:  J Magn Reson B       Date:  1994-05

5.  Diurnal stability of gamma-aminobutyric acid concentration in visual and sensorimotor cortex.

Authors:  Christopher John Evans; David John McGonigle; Richard Anthony Edward Edden
Journal:  J Magn Reson Imaging       Date:  2010-01       Impact factor: 4.813

Review 6.  A guide to the metabolic pathways and function of metabolites observed in human brain 1H magnetic resonance spectra.

Authors:  Caroline D Rae
Journal:  Neurochem Res       Date:  2013-11-21       Impact factor: 3.996

Review 7.  Proton MRS in neurological disorders.

Authors:  S Bonavita; F Di Salle; G Tedeschi
Journal:  Eur J Radiol       Date:  1999-05       Impact factor: 3.528

8.  Gannet: A batch-processing tool for the quantitative analysis of gamma-aminobutyric acid–edited MR spectroscopy spectra.

Authors:  Richard A E Edden; Nicolaas A J Puts; Ashley D Harris; Peter B Barker; C John Evans
Journal:  J Magn Reson Imaging       Date:  2013-11-13       Impact factor: 4.813

9.  Decreased motor cortex γ-aminobutyric acid in amyotrophic lateral sclerosis.

Authors:  B R Foerster; B C Callaghan; M Petrou; R A E Edden; T L Chenevert; E L Feldman
Journal:  Neurology       Date:  2012-04-18       Impact factor: 9.910

10.  Frequency and phase correction for multiplexed edited MRS of GABA and glutathione.

Authors:  Mark Mikkelsen; Muhammad G Saleh; Jamie Near; Kimberly L Chan; Tao Gong; Ashley D Harris; Georg Oeltzschner; Nicolaas A J Puts; Kim M Cecil; Iain D Wilkinson; Richard A E Edden
Journal:  Magn Reson Med       Date:  2017-12-07       Impact factor: 4.668

View more
  14 in total

1.  An evaluation of the reproducibility of 1H-MRS GABA and GSH levels acquired in healthy volunteers with J-difference editing sequences at varying echo times.

Authors:  James J Prisciandaro; Mark Mikkelsen; Muhammad G Saleh; Richard A E Edden
Journal:  Magn Reson Imaging       Date:  2019-11-07       Impact factor: 2.546

2.  Osprey: Open-source processing, reconstruction & estimation of magnetic resonance spectroscopy data.

Authors:  Georg Oeltzschner; Helge J Zöllner; Steve C N Hui; Mark Mikkelsen; Muhammad G Saleh; Sofie Tapper; Richard A E Edden
Journal:  J Neurosci Methods       Date:  2020-06-27       Impact factor: 2.390

3.  In vivo spectral editing of phosphorylethanolamine.

Authors:  Steve C N Hui; Helge J Zöllner; Georg Oeltzschner; Richard A E Edden; Muhammad G Saleh
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

4.  Comparison of Multivendor Single-Voxel MR Spectroscopy Data Acquired in Healthy Brain at 26 Sites.

Authors:  Michal Považan; Mark Mikkelsen; Adam Berrington; Pallab K Bhattacharyya; Maiken K Brix; Pieter F Buur; Kim M Cecil; Kimberly L Chan; David Y T Chen; Alexander R Craven; Koen Cuypers; Michael Dacko; Niall W Duncan; Ulrike Dydak; David A Edmondson; Gabriele Ende; Lars Ersland; Megan A Forbes; Fei Gao; Ian Greenhouse; Ashley D Harris; Naying He; Stefanie Heba; Nigel Hoggard; Tun-Wei Hsu; Jacobus F A Jansen; Alayar Kangarlu; Thomas Lange; R Marc Lebel; Yan Li; Chien-Yuan E Lin; Jy-Kang Liou; Jiing-Feng Lirng; Feng Liu; Joanna R Long; Ruoyun Ma; Celine Maes; Marta Moreno-Ortega; Scott O Murray; Sean Noah; Ralph Noeske; Michael D Noseworthy; Georg Oeltzschner; Eric C Porges; James J Prisciandaro; Nicolaas A J Puts; Timothy P L Roberts; Markus Sack; Napapon Sailasuta; Muhammad G Saleh; Michael-Paul Schallmo; Nicholas Simard; Diederick Stoffers; Stephan P Swinnen; Martin Tegenthoff; Peter Truong; Guangbin Wang; Iain D Wilkinson; Hans-Jörg Wittsack; Adam J Woods; Hongmin Xu; Fuhua Yan; Chencheng Zhang; Vadim Zipunnikov; Helge J Zöllner; Richard A E Edden; Peter B Barker
Journal:  Radiology       Date:  2020-02-11       Impact factor: 11.105

5.  GSH and GABA decreases in IDH1-mutated low-grade gliomas detected by HERMES spectral editing at 3 T in vivo.

Authors:  Tao Gong; Xia Zhang; Xinhong Wei; Shuhui Yuan; Muhammad G Saleh; Yulu Song; Richard A Edden; Guangbin Wang
Journal:  Neurochem Int       Date:  2020-10-22       Impact factor: 3.921

6.  Simultaneous edited MRS of GABA, glutathione, and ethanol.

Authors:  Muhammad G Saleh; Min Wang; Mark Mikkelsen; Steve C N Hui; Georg Oeltzschner; Jeff Boissoneault; Bethany Stennett; Richard A E Edden; Eric C Porges
Journal:  NMR Biomed       Date:  2020-01-14       Impact factor: 4.044

7.  Spectral editing in 1 H magnetic resonance spectroscopy: Experts' consensus recommendations.

Authors:  In-Young Choi; Ovidiu C Andronesi; Peter Barker; Wolfgang Bogner; Richard A E Edden; Lana G Kaiser; Phil Lee; Małgorzata Marjańska; Melissa Terpstra; Robin A de Graaf
Journal:  NMR Biomed       Date:  2020-09-18       Impact factor: 4.044

8.  Influence of editing pulse flip angle on J-difference MR spectroscopy.

Authors:  Sofie Tapper; Steve C N Hui; Muhammad G Saleh; Helge J Zöllner; Georg Oeltzschner; Jamie Near; Brian J Soher; Richard A E Edden
Journal:  Magn Reson Med       Date:  2021-09-14       Impact factor: 4.668

9.  MEGA-PRESS of GABA+: Influences of acquisition parameters.

Authors:  Dinesh K Deelchand; Małgorzata Marjańska; Pierre-Gilles Henry; Melissa Terpstra
Journal:  NMR Biomed       Date:  2019-10-28       Impact factor: 4.044

10.  The trajectory of cortical GABA across the lifespan, an individual participant data meta-analysis of edited MRS studies.

Authors:  Eric C Porges; Greg Jensen; Brent Foster; Richard Ae Edden; Nicolaas Aj Puts
Journal:  Elife       Date:  2021-06-01       Impact factor: 8.140

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.