Literature DB >> 24183860

Development and validation of a treatment planning system for small animal radiotherapy: SmART-Plan.

Stefan J van Hoof1, Patrick V Granton, Frank Verhaegen.   

Abstract

BACKGROUND AND
PURPOSE: Image-guided equipment for precision irradiation of small animals for pre-clinical radiotherapy research became recently available. To enable downscaled radiotherapy studies that can be translated into human radiotherapy knowledge, a treatment planning system for pre-clinical studies is required.
MATERIAL AND METHODS: A dedicated treatment planning system (SmART-Plan) for small animal radiotherapy studies was developed. It is based on Monte Carlo simulation of particle transport in an animal. The voxel geometry is derived from the onboard cone beam CT imaging panel. SmART-Plan was validated using radiochromic film (RCF) dosimetry in various phantoms: uniform, multislab and a realistic plasticized mouse geometry.
RESULTS: Good agreement was obtained between SmART-Plan dose calculations and RCF dose measurements in all phantoms. For various delivered plans agreement was obtained within 10% for the majority of the targeted dose region, with larger differences between 10% and 20% near the penumbra regions and for the smallest 1mm collimator. Absolute depth and lateral dose distributions showed better agreement for 5 and 15-mm collimators than for a 1-mm collimator, indicating that accurate dose prediction for the smallest field sizes is difficult.
CONCLUSION: SmART-Plan offers a useful dose calculation tool for pre-clinical small animal irradiation studies.
Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

Entities:  

Keywords:  Cone beam CT; Pre clinical studies; Precision irradiation; Radiotherapy; Small animals; Treatment planning system

Mesh:

Year:  2013        PMID: 24183860     DOI: 10.1016/j.radonc.2013.10.003

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  45 in total

1.  Radiation dose uncertainty and correction for a mouse orthotopic and xenograft irradiation model.

Authors:  Gregory N Gan; Cem Altunbas; John J Morton; Justin Eagles; Jennifer Backus; Wayne Dzingle; David Raben; Antonio Jimeno
Journal:  Int J Radiat Biol       Date:  2015-12-21       Impact factor: 2.694

2.  Murine vs human tissue compositions: implications of using human tissue compositions for photon energy absorption in mice.

Authors:  Lotte Ejr Schyns; Daniëlle Bp Eekers; Brent van der Heyden; Isabel P Almeida; Ana Vaniqui; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-11-30       Impact factor: 3.039

3.  Imaging and Dosimetry Study of Inter-fraction Setup Error in a Murine Xenograft Flank Tumor Radiation Model.

Authors:  Emily J Smith; Erik J Tryggestad; Brett L Carlson; Matthew C Walb; Jann N Sarkaria
Journal:  Radiat Res       Date:  2019-12-26       Impact factor: 2.841

Review 4.  Small animal image-guided radiotherapy: status, considerations and potential for translational impact.

Authors:  K T Butterworth; K M Prise; F Verhaegen
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

5.  Exploring the feasibility of a clinical proton beam with an adaptive aperture for pre-clinical research.

Authors:  Isabel P Almeida; Ana Vaniqui; Lotte Ejr Schyns; Brent van der Heyden; James Cooley; Townsend Zwart; Armin Langenegger; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-11-07       Impact factor: 3.039

6.  Dose painting by dynamic irradiation delivery on an image-guided small animal radiotherapy platform.

Authors:  Stefan J van Hoof; Joana B Verde; Frank Verhaegen
Journal:  Br J Radiol       Date:  2019-02-12       Impact factor: 3.039

7.  The potential impact of ultrathin filter design on dosimetry and relative biological effectiveness in modern image-guided small animal irradiators.

Authors:  Yannick Poirier; Christopher Daniel Johnstone; Charles Kirkby
Journal:  Br J Radiol       Date:  2018-11-15       Impact factor: 3.039

8.  A novel data management platform to improve image-guided precision preclinical biological research.

Authors:  Lucas Persoon; Stefan van Hoof; Frank van der Kruijssen; Patrick Granton; Andrea Sanchez Rivero; Harold Beunk; Ludwig Dubois; Jan-Willem Doosje; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-10-11       Impact factor: 3.039

9.  Automatic multiatlas based organ at risk segmentation in mice.

Authors:  Brent van der Heyden; Mark Podesta; Daniëlle Bp Eekers; Ana Vaniqui; Isabel P Almeida; Lotte Ejr Schyns; Stefan J van Hoof; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-07-25       Impact factor: 3.039

10.  The influence of respiratory motion on dose delivery in a mouse lung tumour irradiation using the 4D MOBY phantom.

Authors:  Brent van der Heyden; Stefan J van Hoof; Lotte E J R Schyns; Frank Verhaegen
Journal:  Br J Radiol       Date:  2016-10-24       Impact factor: 3.039

View more